Roll-over shape of a prosthetic foot: a finite element evaluation and experimental validation

被引:0
|
作者
Thirunindravur Mannan Balaramakrishnan
Sundararajan Natarajan
Sujatha Srinivasan
机构
[1] Indian Institute of Technology Madras,TTK Center for Rehabilitation Research and Device Development (R2D2), Department of Mechanical Engineering
关键词
Finite element analysis; Gait; Artificial limbs; Foot; Walking;
D O I
暂无
中图分类号
学科分类号
摘要
Prosthetic feet have generally been designed experimentally by adopting a trial-and-error technique. The objective of this research is to introduce a novel numerical approach for the a priori evaluation of the roll-over shape (ROS) of a prosthetic foot for application in its systematic design and development. The ROS was achieved numerically by employing a non-linear finite element model incorporating the augmented Lagrangian and multi-point constraint contact formulations, a hyperelastic material model and a higher-order strain definition. The Ottobock Solid Ankle Cushion Heel (SACH) foot was chosen to experimentally validate the numerical model. The geometry of the foot was evaluated from optical scans, and the material properties were obtained from uniaxial tensile, shear and volumetric compression tests. A new setup was designed for an improved experimental determination of the ROS, with the inclusion of an extended moment arm and variable loading. Error analysis of the radius of curvature of the ROS between the numerical and experimental results showed the percentage error to be 7.52%, thereby establishing the validity of the model. A numerical design model of this kind can be utilised to vary the input design parameters to arrive at a prosthetic foot with specified performance characteristics effectively and economically.
引用
收藏
页码:2259 / 2270
页数:11
相关论文
共 50 条
  • [1] Roll-over shape of a prosthetic foot: a finite element evaluation and experimental validation
    Balaramakrishnan, Thirunindravur Mannan
    Natarajan, Sundararajan
    Srinivasan, Sujatha
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2020, 58 (10) : 2259 - 2270
  • [2] Prosthetic foot design optimisation based on roll-over shape and ground reaction force characteristics
    Mahmoodi, P.
    Aristodemou, S.
    Ransing, R. S.
    Owen, N.
    Friswell, M. I.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2017, 231 (17) : 3093 - 3103
  • [3] DESIGN AND QUALITATIVE TESTING OF A PROSTHETIC FOOT WITH ROTATIONAL ANKLE AND METATARSAL JOINTS TO MIMIC PHYSIOLOGICAL ROLL-OVER SHAPE
    Olesnavage, Kathryn M.
    Winter, Amos G., V
    INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2015, VOL 5A, 2016,
  • [4] The effects of prosthetic foot roll-over shape arc length on the gait of trans-tibial prosthesis users
    Hansen, Andrew H.
    Meier, Margrit R.
    Sessoms, Pinata H.
    Childress, Dudley S.
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2006, 30 (03) : 286 - 299
  • [5] The determination of foot/ankle roll-over shape: Clinical and research applications
    Hansen, A
    Gard, S
    Childress, D
    PEDIATRIC GAIT: A NEW MILLENNIUM IN CLINICAL CARE AND MOTION ANALYSIS TECHNOLOGY, 2000, : 159 - 165
  • [6] Comparative roll-over analysis of prosthetic feet
    Curtze, Carolin
    Hof, At L.
    van Keeken, Helco G.
    Halbertsma, Jan P. K.
    Postema, Klaas
    Otten, Bert
    JOURNAL OF BIOMECHANICS, 2009, 42 (11) : 1746 - 1753
  • [7] Prosthetic foot roll-over shapes with implications for alignment of trans-tibial prostheses
    Hansen, AH
    Childress, DS
    Knox, EH
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2000, 24 (03) : 205 - 215
  • [8] Investigations of roll-over shape: implications for design, alignment, and evaluation of ankle-foot prostheses and orthoses
    Hansen, Andrew H.
    Childress, Dudley S.
    DISABILITY AND REHABILITATION, 2010, 32 (26) : 2201 - 2209
  • [9] Effect of ankle-foot orthosis on roll-over shape in adults with hemiplegia
    Fatone, Stefania
    Hansen, Andrew H.
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2007, 44 (01): : 11 - 20
  • [10] Validation of a finite element program for the design of roll-over protective framed structures (ROPS) for agricultural tractors
    Fabbri, A
    Ward, S
    BIOSYSTEMS ENGINEERING, 2002, 81 (03) : 287 - 296