The effects of prosthetic foot roll-over shape arc length on the gait of trans-tibial prosthesis users

被引:74
|
作者
Hansen, Andrew H.
Meier, Margrit R.
Sessoms, Pinata H.
Childress, Dudley S.
机构
[1] Northwestern Univ, Feinberg Sch Med, Dept Phys Med & Rehabil, Chicago, IL 60611 USA
[2] Northwestern Univ, McCormick Sch Engn & Appl Sci, Dept Biomed Engn, Evanston, IL USA
关键词
trans-tibial; prosthetics; foot shape; gait;
D O I
10.1080/03093640600816982
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The Shape&Roll prosthetic foot was used to examine the effect of roll-over shape arc length on the gait of 14 unilateral trans-tibial prosthesis users. Simple modifications to the prosthetic foot were used to alter the effective forefoot rocker length, leaving factors such as alignment, limb length, and heel and mid-foot characteristics unchanged. Shortening the roll-over shape arc length caused a significant reduction in the maximum external dorsiflexion moment on the prosthetic side at all walking speeds (p < 0.001 for main effect of arc length), due to a reduction in forefoot leverage (moment arm) about the ankle. Roll-over shape arc length significantly affected the initial loading on the sound limb at normal and fast speeds (p = 0.001 for the main effect of arc length), with participants experiencing larger first peaks of vertical ground reaction forces on their sound limbs when using the foot with the shortest effective forefoot rocker arc length. Additionally, the difference between step lengths on the sound and prosthetic limbs was larger with the shortest arc length condition, although this difference was not statistically significant (p = 0.06 for main effect). It appears that prosthesis users may experience a drop-off effect at the end of single limb stance on prosthetic feet with short roll-over shape arc lengths, leading to increased loading and/or a shortened step on the contralateral limb.
引用
收藏
页码:286 / 299
页数:14
相关论文
共 17 条
  • [1] Prosthetic foot roll-over shapes with implications for alignment of trans-tibial prostheses
    Hansen, AH
    Childress, DS
    Knox, EH
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2000, 24 (03) : 205 - 215
  • [2] Alignment of trans-tibial prostheses based on roll-over shape principles
    Hansen, AH
    Meier, MR
    Sam, M
    Childress, DS
    Edwards, ML
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2003, 27 (02) : 89 - 99
  • [3] The influence of prosthetic foot alignment on trans-tibial amputee gait
    Fridman, A
    Ona, I
    Isakov, E
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2003, 27 (01) : 17 - 22
  • [4] Roll-over shape of a prosthetic foot: a finite element evaluation and experimental validation
    Thirunindravur Mannan Balaramakrishnan
    Sundararajan Natarajan
    Sujatha Srinivasan
    Medical & Biological Engineering & Computing, 2020, 58 : 2259 - 2270
  • [5] Roll-over shape of a prosthetic foot: a finite element evaluation and experimental validation
    Balaramakrishnan, Thirunindravur Mannan
    Natarajan, Sundararajan
    Srinivasan, Sujatha
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2020, 58 (10) : 2259 - 2270
  • [6] Effects of socket size on metrics of socket fit in trans-tibial prosthesis users
    Sanders, Joan E.
    Youngblood, Robert T.
    Hafner, Brian J.
    Cagle, John C.
    McLean, Jake B.
    Redd, Christian B.
    Dietrich, Colin R.
    Ciol, Marcia A.
    Allyn, Katheryn J.
    MEDICAL ENGINEERING & PHYSICS, 2017, 44 : 32 - 43
  • [7] Effects of physical exertion on trans-tibial prosthesis users' ability to accommodate alignment perturbations
    Fiedler, Goeran
    Slavens, Brooke A.
    O'Connor, Kristian M.
    Smith, Roger O.
    Hafner, Brian J.
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2016, 40 (01) : 75 - 82
  • [8] Roll-Over Shape-Based Design of Novel Biomimetic Ankle-Foot Prosthesis
    Schlafly, Millicent
    Reed, Kyle B.
    JOURNAL OF PROSTHETICS AND ORTHOTICS, 2021, 33 (04) : 279 - 293
  • [9] Prosthetic foot design optimisation based on roll-over shape and ground reaction force characteristics
    Mahmoodi, P.
    Aristodemou, S.
    Ransing, R. S.
    Owen, N.
    Friswell, M. I.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2017, 231 (17) : 3093 - 3103
  • [10] Effects of prosthetic foot forefoot flexibility on gait of unilateral transtibial prosthesis users
    Klodd, Elizabeth
    Hansen, Andrew
    Fatone, Stefania
    Edwards, Mark
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2010, 47 (09): : 899 - 909