Roll-over shape of a prosthetic foot: a finite element evaluation and experimental validation

被引:0
|
作者
Thirunindravur Mannan Balaramakrishnan
Sundararajan Natarajan
Sujatha Srinivasan
机构
[1] Indian Institute of Technology Madras,TTK Center for Rehabilitation Research and Device Development (R2D2), Department of Mechanical Engineering
关键词
Finite element analysis; Gait; Artificial limbs; Foot; Walking;
D O I
暂无
中图分类号
学科分类号
摘要
Prosthetic feet have generally been designed experimentally by adopting a trial-and-error technique. The objective of this research is to introduce a novel numerical approach for the a priori evaluation of the roll-over shape (ROS) of a prosthetic foot for application in its systematic design and development. The ROS was achieved numerically by employing a non-linear finite element model incorporating the augmented Lagrangian and multi-point constraint contact formulations, a hyperelastic material model and a higher-order strain definition. The Ottobock Solid Ankle Cushion Heel (SACH) foot was chosen to experimentally validate the numerical model. The geometry of the foot was evaluated from optical scans, and the material properties were obtained from uniaxial tensile, shear and volumetric compression tests. A new setup was designed for an improved experimental determination of the ROS, with the inclusion of an extended moment arm and variable loading. Error analysis of the radius of curvature of the ROS between the numerical and experimental results showed the percentage error to be 7.52%, thereby establishing the validity of the model. A numerical design model of this kind can be utilised to vary the input design parameters to arrive at a prosthetic foot with specified performance characteristics effectively and economically.
引用
收藏
页码:2259 / 2270
页数:11
相关论文
共 50 条
  • [41] Roll-over shapes of the ankle-foot and knee-ankle-foot systems of able-bodied children
    Hansen, Andrew H.
    Meier, Margrit R.
    CLINICAL BIOMECHANICS, 2010, 25 (03) : 248 - 255
  • [42] Foot/Ankle Roll-Over Characteristics According to Different Heel Heights of Shoe during Walking
    Kim, Young-Ho
    Choi, Hue-Seok
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2005, 25 (04) : 247 - 253
  • [43] Development and Experimental Evaluation of a National Prosthetic Foot
    Oliveira, D. S.
    Rosa, S. S. R. F.
    IEEE LATIN AMERICA TRANSACTIONS, 2018, 16 (03) : 741 - 747
  • [44] Temporal parameters of the foot roll-over during walking: Influence of obesity and sarcopenic obesity on postmenopausal women
    Monteiro, Marco A.
    Gabriel, Ronaldo C.
    Sousa, Mario F.
    Neves e Castro, Manuel
    Moreira, Maria H.
    MATURITAS, 2010, 67 (02) : 178 - 185
  • [45] Foot/ankle roll-over characteristics for different joint alignments of the ankle-foot orthosis (AFO) during level walking
    Choi, Hueseok
    Kim, Youngho
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 872 - +
  • [46] Validation of Experimental and Finite Element Biomechanical Evaluation of Human Cadaveric Mandibles
    Ingawale, Shirish M.
    Krishnan, Deepak G.
    Goswami, Tarun
    LUBRICANTS, 2022, 10 (08)
  • [47] Experimental validation of finite element modeling
    Vogel, D
    Jian, C
    De Wolf, I
    BENEFITING FROM THERMAL AND MECHANICAL SIMULATION IN MICRO-ELECTRONICS, 2000, : 113 - 133
  • [48] Experimental and Finite Element Investigation of Roll Drawing Process
    Lambiase, F.
    Di Ilio, A.
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2012, 21 (02) : 161 - 166
  • [49] Experimental and Finite Element Investigation of Roll Drawing Process
    F. Lambiase
    A. Di Ilio
    Journal of Materials Engineering and Performance, 2012, 21 : 161 - 166
  • [50] Beam Shape Sensing Using Inverse Finite Element Method: Theory and Experimental Validation
    Gherlone, M.
    Cerracchio, P.
    Mattone, M.
    Di Sciuva, M.
    Tessler, A.
    STRUCTURAL HEALTH MONITORING 2011: CONDITION-BASED MAINTENANCE AND INTELLIGENT STRUCTURES, VOL 1, 2011, : 578 - +