Cross-infection in contrast injectors is still a subject under discussion with little understanding. This study evaluated the biosafety of non-return valves (NRVs). Initially, the maximum pressure during backflow of intact and disrupted flexible diaphragms (FDs) from NRVs, as well as the functionality of connectors with NRVs were verified. The performance of air columns interposed by water in connectors with NRVs was analyzed, and the diffusion distance of crystal violet through connectors with NRVs was measured. The efficacy of NRVs as a barrier to bacterial contamination from backflow was evaluated. Finally, a clinical study of bacteriological contamination from syringes was conducted. There were differences among the maximum tolerated pressure by intact and disrupted FDs. Disrupted FDs showed no failures in the functionality of connectors with NRVs based on the lack of air bubbles released. Air columns could move through connectors with NRVs with intact and disrupted FDs. The longest diffusion distance of crystal violet was 6 cm of connector length, and NRVs showed efficacy as a barrier to bacterial contamination. In the clinical study, there was no bacterial growth in any of the evaluated samples. In conclusion, biosafety depends on the functionality of NRVs as well as proper practical clinical performance.
引用
收藏
相关论文
共 50 条
  • [31] EFFECT OF NON-RETURN VALVES FITTED INTO THE MILKING MACHINE CLUSTER ON MILKING CHARACTERISTICS OF COWS AND TEAT END MEASUREMENTS AFTER MILKING
    LEDU, J
    TAVERNA, M
    MILCHWISSENSCHAFT-MILK SCIENCE INTERNATIONAL, 1990, 45 (01): : 15 - 17
  • [32] The Effect of Non-return Naive on Micro Injection Molding Machine
    Huang, Ruihuan
    Zhou, Gang
    Dong, Liqun
    Zhang, Yajun
    MATERIALS PROCESSING AND MANUFACTURING III, PTS 1-4, 2013, 753-755 : 1495 - +
  • [33] A NON-RETURN VALVE FOR CONTINUOUS USE WITH EMERSON POSTOPERATIVE VENTILATOR
    BERRY, PR
    PONTOPPI.H
    ANESTHESIOLOGY, 1968, 29 (04) : 828 - &
  • [34] NON-RETURN TO INDUSTRY - DOMINANT TRAIT OF TURKISH MIGRATORY CHAIN
    ABADAN, N
    SOCIOLOGIE DU TRAVAIL, 1972, (03) : 278 - 293
  • [35] The Carrier-Based Sensor Deployment in Linear IWSNs With Return/Non-Return Branches
    Cheng, Chien-Fu
    Chen, You-Cyun
    IEEE SENSORS JOURNAL, 2022, 22 (06) : 6175 - 6186
  • [36] BULL NON-RETURN RATE AS A MEASURE OF DAIRY COW FERTILITY
    OLTENACU, EAB
    FOOTE, RH
    BEAN, B
    JOURNAL OF DAIRY SCIENCE, 1977, 60 : 87 - 87
  • [37] Predicting non-return to work in patients attending cardiac rehabilitation
    Samkange-Zeeb, F
    Altenhöner, T
    Berg, G
    Schott, T
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2006, 29 (01) : 43 - 49
  • [38] NUMBER OF SPERMATOZOA PER INSEMINATION AND NON-RETURN RATE IN CATTLE
    KUPFERSCHMIED, H
    GAILLARD, C
    RANARISON, J
    ZUCHTHYGIENE-REPRODUCTION IN DOMESTIC ANIMALS, 1981, 16 (05): : 206 - 211
  • [39] Incorrect assembly of non-return valve of an Oxylog ventilator - Reply
    Redpath, MS
    ANAESTHESIA, 2005, 60 (02) : 210 - 211
  • [40] NON RETURN VALVES FOR FILTER PUMPS
    MOODY, DP
    CHEMISTRY & INDUSTRY, 1971, (19) : 501 - &