Biosafety of Non-Return Valves for Infusion Systems in Radiology

被引:0
|
作者
Marcela Padilha Facetto Azevedo
Rachel Maciel Monteiro
Carla Castelani
Felipe Lazarini Bim
Lucas Lazarini Bim
Ana Paula Macedo
Viviane de Cássia Oliveira
Evandro Watanabe
机构
[1] College of Nursing of Ribeirão Preto,Department of Fundamental Nursing
[2] University of São Paulo,Department of Restorative Dentistry
[3] School of Dentistry of Ribeirão Preto,Department of Dental Materials and Prosthodontics
[4] University of São Paulo,undefined
[5] School of Dentistry of Ribeirão Preto,undefined
[6] University of São Paulo,undefined
[7] University of Valley of the Sinos River (Unisinos),undefined
[8] São Leopoldo,undefined
[9] in the Metropolitan Area of Porto Alegre,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Cross-infection in contrast injectors is still a subject under discussion with little understanding. This study evaluated the biosafety of non-return valves (NRVs). Initially, the maximum pressure during backflow of intact and disrupted flexible diaphragms (FDs) from NRVs, as well as the functionality of connectors with NRVs were verified. The performance of air columns interposed by water in connectors with NRVs was analyzed, and the diffusion distance of crystal violet through connectors with NRVs was measured. The efficacy of NRVs as a barrier to bacterial contamination from backflow was evaluated. Finally, a clinical study of bacteriological contamination from syringes was conducted. There were differences among the maximum tolerated pressure by intact and disrupted FDs. Disrupted FDs showed no failures in the functionality of connectors with NRVs based on the lack of air bubbles released. Air columns could move through connectors with NRVs with intact and disrupted FDs. The longest diffusion distance of crystal violet was 6 cm of connector length, and NRVs showed efficacy as a barrier to bacterial contamination. In the clinical study, there was no bacterial growth in any of the evaluated samples. In conclusion, biosafety depends on the functionality of NRVs as well as proper practical clinical performance.
引用
收藏
相关论文
共 50 条
  • [21] Improved noise performance in non-return to zero systems by use of distributed fibre amplifiers
    Nissov, M
    Poulsen, HN
    Pedersen, RJ
    Jorgensen, BF
    Newhouse, MA
    Antos, AJ
    ELECTRONICS LETTERS, 1996, 32 (20) : 1905 - 1907
  • [22] The non-return of the rural young people displaced in Caldas
    Velasquez Ortiz, Yonathan Amed
    REVISTA CES DERECHO, 2021, 12 (02): : 23 - 63
  • [23] Reasons for Non-Return to A Pediatric Weight Management Program
    Kitscha, Catherine E.
    Brunet, Kim
    Farmer, Anna
    Mager, Diana R.
    CANADIAN JOURNAL OF DIETETIC PRACTICE AND RESEARCH, 2009, 70 (02) : 89 - 94
  • [24] The Problem of Non-Return of Cultural Valuables to the Russian Federation
    Pershikov, A. N.
    Royzen, E. A.
    Kondrushin, V. U.
    III INTERNATIONAL SCIENTIFIC SYMPOSIUM ON LIFELONG WELLBEING IN THE WORLD (WELLSO 2016), 2017, 19 : 523 - 528
  • [25] MULTIWAY NON-RETURN VALVE FOR USE IN PHYSIOLOGICAL EXPERIMENTS
    HOLDER, RED
    SATTELLE, DB
    JOURNAL OF PHYSIOLOGY-LONDON, 1972, 226 (02): : P2 - &
  • [26] Non-return valve with distributive and dispersive mixing capability
    Rauwendaal, C
    ANTEC 2000: SOCIETY OF PLASTICS ENGINEERS TECHNICAL PAPERS, CONFERENCE PROCEEDINGS, VOLS I-III, 2000, : 638 - 641
  • [27] Validation of non-return rate as a parameter for stallion fertility
    van Buiten, A
    van den Broek, J
    Schukken, YH
    Colenbrander, B
    LIVESTOCK PRODUCTION SCIENCE, 1999, 60 (01): : 13 - 19
  • [28] SITE OF INSEMINATION AND SUBSEQUENT NON-RETURN RATES IN COWS
    MOLLER, K
    SHANNON, P
    MACMILLAN, KL
    NEW ZEALAND JOURNAL OF AGRICULTURAL RESEARCH, 1972, 15 (02) : 252 - +
  • [29] The door to the non-return journey or the notebooks of Michel Adanson
    Biondi, Carminella
    STUDI FRANCESI, 2022, 66 (03) : 733 - 734
  • [30] How to tell if your non-return valve is leaking
    Bozzelli, John
    Plastics Technology, 2014, 60 (11) : 32 - 34