Effect of the saturation pulse duration on chemical exchange saturation transfer in amide proton transfer MR imaging: a phantom study

被引:12
|
作者
Wada T. [1 ]
Togao O. [2 ]
Tokunaga C. [1 ]
Funatsu R. [1 ]
Kobayashi K. [1 ]
Nakamura Y. [1 ]
机构
[1] Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1, Maidashi, Higashi-ku, Fukuoka
[2] Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1, Maidashi, Higashi-ku, Fukuoka
基金
日本学术振兴会;
关键词
Amide proton transfer (APT) imaging; Chemical exchange saturation transfer (CEST); Chicken egg white; Parallel RF transmission; Saturation pulse duration;
D O I
10.1007/s12194-015-0326-1
中图分类号
学科分类号
摘要
Amide proton transfer (APT) contrast imaging is based on the chemical exchange saturation transfer (CEST) of protons between the amide groups and bulk water. Here, we demonstrate the effect of the saturation pulse duration on CEST in APT imaging with use of a clinical MR scanner. Four samples were prepared from chicken egg white diluted with H2O. Experiments were performed on a 3T clinical MR scanner with use of a body coil for two-channel parallel radiofrequency transmission. APT images were acquired at six frequency offsets (± 3.0, ± 3.5, ± 4.0 ppm) with respect to the water resonance as well as one far off-resonant frequency (−160 ppm) for signal normalization. The CEST effect was defined as asymmetry of the magnetization transfer ratio at 3.5 ppm. We measured the CEST effects in the egg white samples with different concentrations at seven saturation pulse durations. The influence of the extension of repetition time (TR) on the CEST effect was also evaluated. The CEST effect was not influenced by the change in TR. The CEST effect was increased significantly with the concentration when the duration was ≥1.0 s (P < 0.01). The CEST effect was highly correlated with the concentration at all saturation pulse durations, and its increase ratio was higher at longer saturation pulse durations. In conclusion, a long saturation pulse duration is useful for the sensitive detection of mobile proteins and peptides in APT imaging. © 2015, Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:15 / 21
页数:6
相关论文
共 50 条
  • [41] Assessment of ischemic penumbra in patients with hyperacute stroke using amide proton transfer (APT) chemical exchange saturation transfer (CEST) MRI
    Tietze, Anna
    Blicher, Jakob
    Mikkelsen, Irene Klaerke
    Ostergaard, Leif
    Strother, Megan K.
    Smith, Seth A.
    Donahue, Manus J.
    NMR IN BIOMEDICINE, 2014, 27 (02) : 163 - 174
  • [42] Optimization of 7-T Chemical Exchange Saturation Transfer Parameters for Validation of Glycosaminoglycan and Amide Proton Transfer of Fibroglandular Breast Tissue
    Dula, Adrienne N.
    Dewey, Blake E.
    Arlinghaus, Lori R.
    Williams, Jason M.
    Klomp, Dennis
    Yankeelov, Thomas E.
    Smith, Seth
    RADIOLOGY, 2015, 275 (01) : 255 - 261
  • [43] Accurate Estimation of the Duration of Testicular Ischemia Using Creatine Chemical Exchange Saturation Transfer (CrCEST) Imaging
    Takahashi, Yusuke
    Kioka, Hidetaka
    Saito, Shigeyoshi
    Fukuhara, Shinichiro
    Asano, Yoshihiro
    Takashima, Seiji
    Yoshioka, Yoshichika
    Sakata, Yasushi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (05) : 1559 - 1567
  • [44] Assessment of Carotid Artery Plaques With Chemical Exchange Saturation Transfer Imaging
    Kanematsu, Yasuhisa
    Kenji, Shimada
    Korai, Masaaki
    Izumi, Yamaguchi
    Nobuaki, Yamamoto
    Yuki, Yamamoto
    Yasushi, Takagi
    STROKE, 2024, 55
  • [45] Characterization of carotid plaques using chemical exchange saturation transfer imaging
    Kanematsu, Yasuhisa
    Kanazawa, Yuki
    Shimada, Kenji
    Korai, Masaaki
    Miyamoto, Takeshi
    Sogabe, Shu
    Ishihara, Manabu
    Yamaguchi, Izumi
    Oya, Takeshi
    Yamamoto, Nobuaki
    Yamamoto, Yuki
    Miyoshi, Mitsuharu
    Harada, Masafumi
    Takagi, Yasushi
    NEURORADIOLOGY, 2024, 66 (09) : 1617 - 1624
  • [46] Optimizing Pulsed-Chemical Exchange Saturation Transfer Imaging Sequences
    Zu, Zhongliang
    Li, Ke
    Janve, Vaibhav A.
    Does, Mark D.
    Gochberg, Daniel F.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (04) : 1100 - 1108
  • [47] pH Imaging Using Chemical Exchange Saturation Transfer (CEST) MRI
    Pavuluri, KowsalyaDevi
    McMahon, Michael T.
    ISRAEL JOURNAL OF CHEMISTRY, 2017, 57 (09) : 862 - 879
  • [48] Chemical exchange saturation transfer contrast agents for magnetic resonance imaging
    Sherry, A. Dean
    Woods, Mark
    ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2008, 10 : 391 - 411
  • [49] Artificial intelligence in chemical exchange saturation transfer magnetic resonance imaging
    Swee Qi Pan
    Yan Chai Hum
    Khin Wee Lai
    Wun-She Yap
    Yi Zhang
    Hye-Young Heo
    Yee Kai Tee
    Artificial Intelligence Review, 58 (7)
  • [50] Insight into the quantitative metrics of chemical exchange saturation transfer (CEST) imaging
    Heo, Hye-Young
    Lee, Dong-Hoon
    Zhang, Yi
    Zhao, Xuna
    Jiang, Shanshan
    Chen, Min
    Zhou, Jinyuan
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (05) : 1853 - 1865