Accurate Estimation of the Duration of Testicular Ischemia Using Creatine Chemical Exchange Saturation Transfer (CrCEST) Imaging

被引:5
|
作者
Takahashi, Yusuke [1 ,2 ]
Kioka, Hidetaka [1 ]
Saito, Shigeyoshi [3 ,4 ]
Fukuhara, Shinichiro [5 ]
Asano, Yoshihiro [1 ]
Takashima, Seiji [6 ]
Yoshioka, Yoshichika [7 ,8 ,9 ]
Sakata, Yasushi [1 ]
机构
[1] Osaka Univ, Dept Cardiovasc Med, Grad Sch Med, Suita, Osaka 5650871, Japan
[2] Natl Cerebral & Cardiovasc Ctr, Dept Mol Pharmacol, Res Inst, Suita, Osaka, Japan
[3] Osaka Univ, Dept Med Phys & Engn, Div Hlth Sci, Grad Sch Med, Suita, Osaka, Japan
[4] Natl Cardiovasc & Cerebral Res Ctr, Dept Biomed Imaging, Suita, Osaka, Japan
[5] Osaka Univ, Dept Urol, Grad Sch Med, Suita, Osaka, Japan
[6] Osaka Univ, Dept Med Biochem, Grad Sch Frontier Biosci, Suita, Osaka, Japan
[7] Osaka Univ, Grad Sch Frontier Biosci, Lab Biofunct Imaging, Suita, Osaka, Japan
[8] Osaka Univ, Ctr Informat & Neural Networks CiNet, Suita, Osaka, Japan
[9] Informat & Commun Technol NICT, Suita, Osaka, Japan
关键词
testicular ischemia; chemical exchange saturation transfer; magnetic resonance imaging; creatine; CEST MRI; TESTES; TORSION; PHOSPHOCREATINE; SPECTROSCOPY; GLIOMAS; MICE;
D O I
10.1002/jmri.27456
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background In the management of testicular torsion, estimating the duration of testicular ischemia is essential for deciding on an appropriate surgical treatment, but there are currently limited evaluation methods. Purpose To perform testicular creatine chemical exchange saturation transfer (CrCEST) imaging and to evaluate its ability to accurately estimate the duration of testicular ischemia. Study Type Prospective. Animal Model C57BL/6 control mice (n = 6) and testicular ischemia models induced by clamping the spermatic cord (n = 14). Eight of testicular ischemia models were serially imaged at two or three timepoints and a total of 26 images of ischemic testis were obtained. The ischemic duration ranged from 6-42 hours. Field Strength/Sequence 11.7T vertical-bore MRI/segment fast low-angle shot acquisition for CEST. Assessment CrCEST imaging was performed and the magnetization transfer ratio for the CrCEST effect (MTRCr**) was calculated in control mice and testicular ischemia models. Correlation analysis between the duration of testicular ischemia and MTRCr** decline was performed. Statistical Tests Paired t-test, and Pearson's correlation analysis. Results In control mice, the CrCEST effect in testes was significantly more than five times higher than that in skeletal muscle. MTRCr** did not differ significantly between the right and left testes (8.6 +/- 0.8 vs. 8.3 +/- 0.6, P = 0.96). In testicular ischemia models, MTRCr** of ischemic testes was significantly lower than that of controls (4 +/- 2 vs. 8.9 +/- 0.6, P < 0.001). Correlation analysis revealed a strong linear correlation between MTRCr** decline and the duration of ischemia (r = 0.96, P < 0.001). Data Conclusion A decreased CrCEST effect in ischemic testes correlated well with ischemic duration. Testicular CrCEST imaging was useful for accurately estimating the duration of testicular ischemia. Level of Evidence 2 Technical Efficacy Stage 2
引用
收藏
页码:1559 / 1567
页数:9
相关论文
共 50 条
  • [1] Editorial for "Accurate Estimation of the Duration of Testicular Ischemia Using Creatine Chemical Exchange Saturation Transfer (CrCEST) Imaging"
    Wang, Xianfeng
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (05) : 1568 - 1569
  • [2] In Vivo Chemical Exchange Saturation Transfer Imaging of Creatine (CrCEST) in Skeletal Muscle at 3T
    Kogan, Feliks
    Haris, Mohammad
    Debrosse, Catherine
    Singh, Anup
    Nanga, Ravi P.
    Cai, Kejia
    Hariharan, Hari
    Reddy, Ravinder
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (03) : 596 - 602
  • [3] Mouse skeletal muscle creatine chemical exchange saturation transfer (CrCEST) imaging at 11.7T MRI
    Takahashi, Yusuke
    Saito, Shigeyoshi
    Kioka, Hidetaka
    Araki, Rikita
    Asano, Yoshihiro
    Takashima, Seiji
    Sakata, Yasushi
    Yoshioka, Yoshichika
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 51 (02) : 563 - 570
  • [4] A NOVEL AND FEASIBLE METHOD FOR QUANTIFYING TESTICULAR SPERAMATOGENESIS BY USING CREATINE CHEMICAL EXCHANGE SATURATION TRANSFER IMAGING
    Kuribayashi, Sohei
    Fukuhara, Shinichiro
    Tsujimura, Go
    Imanaka, Takahiro
    Okada, Koichi
    Ueda, Norichika
    Takezawa, Kentaro
    Saito, Shigeyoshi
    Takahashi, Yusuke
    Kioka, Hidetaka
    Nonomura, Norio
    JOURNAL OF UROLOGY, 2023, 209 : E5 - E6
  • [5] Evaluating the Cisplatin Dose Dependence of Testicular Dysfunction Using Creatine Chemical Exchange Saturation Transfer Imaging
    Sawaya, Reika
    Kuribayashi, Sohei
    Ueda, Junpei
    Saito, Shigeyoshi
    DIAGNOSTICS, 2022, 12 (05)
  • [6] Evaluation of the efficacy of creatine chemical exchange saturation transfer imaging in assessing testicular maturity
    Kuribayashi, Sohei
    Fukuhara, Shinichiro
    Tsujimura, Go
    Imanaka, Takahiro
    Okada, Koichi
    Ueda, Norichika
    Takezawa, Kentaro
    Kiuchi, Hiroshi
    Saito, Shigeyoshi
    Takahashi, Yusuke
    Kioka, Hidetaka
    Oura, Seiya
    Shimada, Keisuke
    Ikawa, Masahito
    Nonomura, Norio
    REPRODUCTIVE MEDICINE AND BIOLOGY, 2023, 22 (01)
  • [7] Muscle oxidative phosphorylation quantitation using creatine chemical exchange saturation transfer (CrCEST) MRI in mitochondrial disorders
    DeBrosse, Catherine
    Nanga, Ravi Prakash Reddy
    Wilson, Neil
    D'Aquilla, Kevin
    Elliott, Mark
    Hariharan, Hari
    Yan, Felicia
    Wade, Kristin
    Sara Nguyen
    Worsley, Diana
    Parris-Skeete, Chevonne
    McCormick, Elizabeth
    Xiao, Rui
    Cunningham, Zuela Zolkipli
    Fishbein, Lauren
    Nathanson, Katherine L.
    Lynch, David R.
    Stallings, Virginia A.
    Yudkoff, Marc
    Falk, Marni J.
    Reddy, Ravinder
    McCormack, Shana E.
    JCI INSIGHT, 2016, 1 (18):
  • [8] Exchange rates of creatine kinase metabolites: feasibility of imaging creatine by chemical exchange saturation transfer MRI
    Haris, Mohammad
    Nanga, Ravi Prakash Reddy
    Singh, Anup
    Cai, Kejia
    Kogan, Feliks
    Hariharan, Hari
    Reddy, Ravinder
    NMR IN BIOMEDICINE, 2012, 25 (11) : 1305 - 1309
  • [9] Method for High-Resolution Imaging of Creatine In Vivo Using Chemical Exchange Saturation Transfer
    Kogan, Feliks
    Haris, Mohammad
    Singh, Anup
    Cai, Kejia
    Debrosse, Catherine
    Nanga, Ravi Prakash Reddy
    Hariharan, Hari
    Reddy, Ravinder
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (01) : 164 - 172
  • [10] Visualization of Spatial Distribution of Spermatogenesis in Mouse Testes Using Creatine Chemical Exchange Saturation Transfer Imaging
    Takahashi, Yusuke
    Kioka, Hidetaka
    Fukuhara, Shinichiro
    Kuribayashi, Sohei
    Saito, Shigeyoshi
    Asano, Yoshihiro
    Takashima, Seiji
    Yoshioka, Yoshichika
    Sakata, Yasushi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 54 (05) : 1457 - 1465