Direct Current Combined With Bipolar Radiofrequency Ablation: An Ex Vivo Feasibility Study

被引:0
|
作者
Toshihiro Tanaka
Tobias Penzkofer
Peter Isfort
Philipp Bruners
Catherine Disselhorst-Klug
Elmar Junker
Kimihiko Kichikawa
Thomas Schmitz-Rode
Andreas H. Mahnken
机构
[1] RWTH Aachen University,Applied Medical Engineering, Helmholtz
[2] RWTH Aachen University,Institute Aachen
[3] Nara Medical University,Department of Diagnostic Radiology, Aachen University Hospital
来源
CardioVascular and Interventional Radiology | 2011年 / 34卷
关键词
Radiofrequency ablation; Liver tumor; Direct current;
D O I
暂无
中图分类号
学科分类号
摘要
The combination of radiofrequency ablation (RFA) with direct current (DC) is a promising strategy to improve the efficiency of RFA. However, DC-enhanced monopolar RFA is limited by electrolytic injury at the positive-electrode site. The aim of this study was to investigate the feasibility of the DC-enhanced bipolar RFA. To obviate the need for the subcutaneous positive electrode, the DC circuit was combined with a commercially available bipolar RFA system, in which both poles of the DC circuit are connected to a single RF probe. DC was applied for 15 min and followed by RFA in bovine livers using the following various DC currents: (1) no DC (control), (2) 3V continued until the end of RFA, (3) 5V continued until the end of RFA, (4) 10V continued until the end of RFA, (5) 5V continued in the circuit with reversed pole, (6) 3V stopped after initiation of RFA, and (7) 5V stopped. Coagulation volume, temperatures at a distance of 5, 10, and 15 mm from the RF probe, mean amperage, ablation duration, applied energy, minimum impedance, and degree of tissue charring were assessed and compared (analysis of variance, Student–Newman–Keuls test). All combined DC and RFA groups did increase coagulation volume. The 10V continued group showed significantly lower applied energy, shortest ablation duration, highest minimum impedance, and highest degree of charring with the lowest coagulation volume (p < 0.05). DC-enhanced bipolar RFA with both poles of the DC circuit on a single probe appears to be ineffective.
引用
收藏
页码:631 / 636
页数:5
相关论文
共 50 条
  • [41] Radiofrequency ablation using injectable cooled electrode: the effects of lidocaine injection in ex vivo study
    Park, Sun-Young
    Chung, Hye Won
    Baek, Jung Hwan
    Lee, Jeong Hyun
    Lee, Min Hee
    Lee, Joon Woo
    ACTA RADIOLOGICA, 2020, 61 (02) : 219 - 226
  • [42] Feasibility of thermal ablation of lytic vertebral metastases with radiofrequency current
    Wood, BJ
    CANCER JOURNAL, 2002, 8 (01): : 26 - 28
  • [43] Comparison of bipolar and unipolar radiofrequency ablation in an in vivo experimental model - Comment
    Benussi, S
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 28 (01) : 80 - 82
  • [44] Case Experience of Radiofrequency Ablation for Benign Thyroid Nodules: From an Ex Vivo Animal Study to an Initial Ablation in Taiwan
    Lee, Ming-Tsang
    Wang, Chih-Yuan
    JOURNAL OF MEDICAL ULTRASOUND, 2016, 24 (01) : 32 - 38
  • [45] A numerical study on the no-touch bipolar radiofrequency ablation
    Yap, Shelley
    Cheong, Jason K. K.
    Ooi, Ean H.
    Liao, Iman Y.
    Foo, Ji J.
    Nair, Shalini R.
    Ali, Ahmad F. Mohd
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 2887 - 2890
  • [46] A Comparative Study of Radiofrequency Ablation in Unipolar and Bipolar Fashion
    王扬淦
    陆再英
    赵华月
    宋玉娥
    李仁立
    同济医科大学学报(外文版), 1995, (02) : 73 - 76
  • [47] The vascular cooling effect in hepatic multipolar radiofrequency ablation leads to incomplete ablation ex vivo
    Poch, Franz G. M.
    Rieder, Christian
    Ballhausen, Hanne
    Knappe, Verena
    Ritz, Joerg-Peter
    Gemeinhardt, Ole
    Kreis, Martin E.
    Lehmann, Kai S.
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2016, 32 (07) : 749 - 756
  • [48] Comparison of hydrochloric acid infusion radiofrequency ablation with microwave ablation in an ex vivo liver model
    Deng, Hanxia
    Zhang, Tianqi
    Jiang, Xiongying
    Huang, Senmiao
    Nan Nancy Jiang
    Lau, Wan-Yee
    Huang Jinhua
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2020, 37 (01) : 600 - 607
  • [49] Microwave Ablation Compared with Radiofrequency Ablation for Breast Tissue in an Ex Vivo Bovine Udder Model
    Toshihiro Tanaka
    Saskia Westphal
    Peter Isfort
    Till Braunschweig
    Tobias Penzkofer
    Philipp Bruners
    Kimihiko Kichikawa
    Thomas Schmitz-Rode
    Andreas H. Mahnken
    CardioVascular and Interventional Radiology, 2012, 35 : 914 - 920
  • [50] Bipolar radiofrequency ablation in ex vivo bovine liver with the open-perfused system versus the cooled-wet system
    Lee, JM
    Han, JK
    Kim, SH
    Sohn, KL
    Choi, SH
    Choi, BI
    EUROPEAN RADIOLOGY, 2005, 15 (04) : 759 - 764