Dual-energy CT of the bone marrow in multiple myeloma: diagnostic accuracy for quantitative differentiation of infiltration patterns

被引:0
|
作者
Aleksander Kosmala
Andreas Max Weng
Bernhard Krauss
Stefan Knop
Thorsten Alexander Bley
Bernhard Petritsch
机构
[1] University Hospital Würzburg,Department of Diagnostic and Interventional Radiology
[2] Siemens Healthcare GmbH,Diagnostic Imaging
[3] University Hospital Würzburg,Department of Internal Medicine II
来源
European Radiology | 2018年 / 28卷
关键词
Bone marrow; Multiple myeloma; Dual-energy scanned projection radiography; Tomography; X-ray computed;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:5083 / 5090
页数:7
相关论文
共 50 条
  • [31] Diagnostic performance of dual-energy CT for the detection of bone marrow oedema: a systematic review and meta-analysis
    Suh, Chong Hyun
    Yun, Seong Jong
    Jin, Wook
    Lee, Sun Hwa
    Park, So Young
    Ryu, Chang-Woo
    EUROPEAN RADIOLOGY, 2018, 28 (10) : 4182 - 4194
  • [32] Diagnostic accuracy of quantitative dual-energy CT-based volumetric bone mineral density assessment for the prediction of osteoporosis-associated fractures
    Gruenewald, Leon D.
    Koch, Vitali
    Martin, Simon S.
    Yel, Ibrahim
    Eichler, Katrin
    Gruber-Rouh, Tatjana
    Lenga, Lukas
    Wichmann, Julian L.
    Alizadeh, Leona S.
    Albrecht, Moritz H.
    Mader, Christoph
    Huizinga, Nicole A.
    D'Angelo, Tommaso
    Mazziotti, Silvio
    Wesarg, Stefan
    Vogl, Thomas J.
    Booz, Christian
    EUROPEAN RADIOLOGY, 2022, 32 (05) : 3076 - 3084
  • [33] Osteomyelitis of the Lower Limb: Diagnostic Accuracy of Dual-Energy CT versus MRI
    Foti, Giovanni
    Longo, Chiara
    Sorgato, Claudia
    Oliboni, Eugenio Simone
    Mazzi, Cristina
    Motta, Leonardo
    Bertoli, Giulia
    Marocco, Stefania
    DIAGNOSTICS, 2023, 13 (04)
  • [34] Diagnostic accuracy of quantitative dual-energy CT-based volumetric bone mineral density assessment for the prediction of osteoporosis-associated fractures
    Leon D. Gruenewald
    Vitali Koch
    Simon S. Martin
    Ibrahim Yel
    Katrin Eichler
    Tatjana Gruber-Rouh
    Lukas Lenga
    Julian L. Wichmann
    Leona S. Alizadeh
    Moritz H. Albrecht
    Christoph Mader
    Nicole A. Huizinga
    Tommaso D’Angelo
    Silvio Mazziotti
    Stefan Wesarg
    Thomas J. Vogl
    Christian Booz
    European Radiology, 2022, 32 : 3076 - 3084
  • [35] Diagnostic accuracy of dual-energy CT and ultrasound in gouty arthritis A systematic review
    Chen, J.
    Liao, M.
    Zhang, H.
    Zhu, D.
    ZEITSCHRIFT FUR RHEUMATOLOGIE, 2017, 76 (08): : 723 - 729
  • [36] Effects of Bone Marrow Infiltration By Multiple Myeloma on Erythropoiesis
    Moyo, Tamara K.
    Bouchnita, Anass
    Eymard, Nathalie
    Volpert, Vitaly
    Koury, Mark J.
    BLOOD, 2015, 126 (23)
  • [37] The Differentiation of Soft Tissue Infiltration and Surrounding Edema in an Animal Model of Malignant Bone Tumor: Evaluation by Dual-Energy CT
    Chen, Haisong
    Zhang, Yuan
    Pang, Jing
    Wu, Zengjie
    Jia, Meng
    Dong, Qian
    Xu, Wenjian
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2019, 18
  • [38] Bone Marrow Edema in Vertebral Compression Fractures: Detection with Dual-Energy CT
    Wang, Chien-Kuo
    Tsai, Jen-Ming
    Chuang, Ming-Tsung
    Wang, Min-Tsung
    Huang, Kuo-Yuan
    Lin, Ruey-Mo
    RADIOLOGY, 2013, 269 (02) : 524 - 532
  • [39] Bone Marrow Edema at Dual-Energy CT: A Game Changer in the Emergency Department
    Gosangi, Babina
    Mandell, Jacob C.
    Weaver, Michael J.
    Uyeda, Jennifer W.
    Smith, Stacy E.
    Sodickson, Aaron D.
    Khurana, Bharti
    RADIOGRAPHICS, 2020, 40 (03) : 859 - 874
  • [40] Quantifying the bone marrow composition of the healthy adult wrist with dual-energy CT
    Muller, Felix C.
    Gosvig, Kasper K.
    Mikkel, Ostergaard
    Bjarne, Roed
    Rodell, Anders
    Henrik, B. orgesen
    Krauss, Bernhard
    Gade, Jesper S.
    Boesen, Mikael
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 139