Optimal design of nuclear power plants containment with tuned mass damper inerter device for earthquake loadings

被引:0
|
作者
Guangcai Han
Yanhong Wu
Gangling Hou
Zhihua Yue
机构
[1] Harbin Engineering University,College of Aerospace and Civil Engineering
[2] Harbin Engineering University,College of Mechanical and Electrical Engineering
来源
Journal of Mechanical Science and Technology | 2023年 / 37卷
关键词
BI-NPPC; TMDI; Optimum parameters; Enhanced performance; Seismic ground motion;
D O I
暂无
中图分类号
学科分类号
摘要
In this paper a novel passive device defined as the tuned mass damper inerter (TMDI) is studied to control the response of a base-isolated nuclear power plant containment (BI-NPPC) structures under stochastic horizontal ground motions. A new method of connecting TMDI to the isolation foundation is proposed. Recently, the TMDI has been introduced as a generalization of the classical TMD to achieve enhanced performance. Consider the case of a base-isolated structure equipped with a TMDI device, which is served as a base-isolated nuclear power plant containment. A particular arrangement of mechanical gearings (inerter) attached to TMD is set, optimum parameters of this system are found based on a simplified two degree of freedom model that reflects the dynamic properties of both the isolation structure and the TMDI. A straightforward numerical approach is developed for the optimal design of this device considering a white noise ground excitation, and a simplified analytical solution for the optimal design of TMDI parameters are introduced and compared with the numerical results in terms of the optimum frequency ratio, the optimum damping ratio and enhanced performance. Within a probabilistic framework, the influence of soil conditions is investigated by modeling the seismic ground motion as a filtered Gaussian random process. Different filter parameters are considered that may be associated with firm, medium or soil conditions depending on the frequency content of the power spectral density function. Several natural recorded accelerograms are also selected to scrutinize the effectiveness of the TMDI isolated-base structure via time-domain analyses. Properties of the BIS are considered in respect of its damping and stiffness. It can be concluded that higher control performances are achieved when lower values of base isolation sub-system damping ratio are used, however, the control performances of the TMDI are basically not affected by small variation of the natural frequency of the isolated-base structure.
引用
收藏
页码:5607 / 5621
页数:14
相关论文
共 50 条
  • [41] Optimal Design and Analysis of Nonlinear Tuned Mass Damper System
    Yao, Ji
    Liu, Junfeng
    Hu, Yujun
    Zhang, Qing
    APPLIED SCIENCES-BASEL, 2023, 13 (14):
  • [42] Design of an optimal tuned mass damper for a system with parametric uncertainty
    Patricia Moreno, Claudia
    Thomson, Peter
    ANNALS OF OPERATIONS RESEARCH, 2010, 181 (01) : 783 - 793
  • [43] Design of an optimal tuned mass damper for a system with parametric uncertainty
    Claudia Patricia Moreno
    Peter Thomson
    Annals of Operations Research, 2010, 181 : 783 - 793
  • [44] Optimum design of base-isolated structure equipped with variant tuned mass damper inerter
    Ye, Kun
    Yang, Qi-Fan
    Chen, Zhen-Ming
    Zhendong Gongcheng Xuebao/Journal of Vibration Engineering, 2024, 37 (08): : 1368 - 1376
  • [45] Multi-tuned mass damper inerter (MTMDI) system for earthquake-induced vibration control of buildings
    Djerouni, Salah
    Elias, Said
    Abdeddaim, Mahdi
    Rupakhety, Rajesh
    ENGINEERING STRUCTURES, 2025, 322
  • [46] Generic optimal design approach for inerter-based tuned mass systems
    Su, Ning
    Bian, Jing
    Peng, Shitao
    Xia, Yi
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2022, 233
  • [47] Optimal design and performance evaluation of a novel hysteretic friction tuned inerter damper for vibration control systems
    Hua, Xu-gang
    Tai, Yu-ji
    Huang, Zhi-wen
    Chen, Zheng-qing
    STRUCTURAL CONTROL & HEALTH MONITORING, 2021, 28 (08):
  • [48] Analytical optimal design and performance evaluation of series tuned inerter damper for ground motion excited structures
    Zhang, Ruoyu
    Huang, Jizhong
    Cao, Meigen
    ARCHIVE OF APPLIED MECHANICS, 2024, 94 (06) : 1739 - 1752
  • [49] Performance and efficiency oriented optimal design of tuned inerter damper for seismic response control of building structures
    Hao, Linfei
    He, Hui
    Tan, Ping
    Jin, Kiwoong
    Liu, Xinyu
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2023, 253
  • [50] Tuned-mass-damper-inerter optimal design and performance assessment for multi-storey hysteretic buildings under seismic excitation
    D. Patsialis
    A. A. Taflanidis
    A. Giaralis
    Bulletin of Earthquake Engineering, 2023, 21 : 1541 - 1576