Optimal design of nuclear power plants containment with tuned mass damper inerter device for earthquake loadings

被引:0
|
作者
Guangcai Han
Yanhong Wu
Gangling Hou
Zhihua Yue
机构
[1] Harbin Engineering University,College of Aerospace and Civil Engineering
[2] Harbin Engineering University,College of Mechanical and Electrical Engineering
来源
Journal of Mechanical Science and Technology | 2023年 / 37卷
关键词
BI-NPPC; TMDI; Optimum parameters; Enhanced performance; Seismic ground motion;
D O I
暂无
中图分类号
学科分类号
摘要
In this paper a novel passive device defined as the tuned mass damper inerter (TMDI) is studied to control the response of a base-isolated nuclear power plant containment (BI-NPPC) structures under stochastic horizontal ground motions. A new method of connecting TMDI to the isolation foundation is proposed. Recently, the TMDI has been introduced as a generalization of the classical TMD to achieve enhanced performance. Consider the case of a base-isolated structure equipped with a TMDI device, which is served as a base-isolated nuclear power plant containment. A particular arrangement of mechanical gearings (inerter) attached to TMD is set, optimum parameters of this system are found based on a simplified two degree of freedom model that reflects the dynamic properties of both the isolation structure and the TMDI. A straightforward numerical approach is developed for the optimal design of this device considering a white noise ground excitation, and a simplified analytical solution for the optimal design of TMDI parameters are introduced and compared with the numerical results in terms of the optimum frequency ratio, the optimum damping ratio and enhanced performance. Within a probabilistic framework, the influence of soil conditions is investigated by modeling the seismic ground motion as a filtered Gaussian random process. Different filter parameters are considered that may be associated with firm, medium or soil conditions depending on the frequency content of the power spectral density function. Several natural recorded accelerograms are also selected to scrutinize the effectiveness of the TMDI isolated-base structure via time-domain analyses. Properties of the BIS are considered in respect of its damping and stiffness. It can be concluded that higher control performances are achieved when lower values of base isolation sub-system damping ratio are used, however, the control performances of the TMDI are basically not affected by small variation of the natural frequency of the isolated-base structure.
引用
收藏
页码:5607 / 5621
页数:14
相关论文
共 50 条
  • [21] Optimal design and assessment of tuned mass damper inerter with nonlinear viscous damper in seismically excited multi-storey buildings
    Rajana, Komal
    Wang, Zixiao
    Giaralis, Agathoklis
    BULLETIN OF EARTHQUAKE ENGINEERING, 2023, 21 (03) : 1509 - 1539
  • [22] Dynamic model and earthquake response of a hybrid isolated system with tuned inerter dampers for nuclear power plants
    Liu, Wenguang
    Feng, Yixin
    Zhang, Qiang
    Xu, Hao
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2022, 163
  • [23] Closed-form solutions for the optimal design of lever-arm tuned mass damper inerter (LTMDI)
    Li, Zhenchuan
    Ma, Ruisheng
    Xu, Kun
    Han, Qiang
    Mechanical Systems and Signal Processing, 2024, 206
  • [24] Dual-Demand-Based Optimal Design of Grounded Tuned Mass Damper Inerter for Seismic Response Mitigation
    Zhang, Ruoyu
    Huang, Jizhong
    Zhang, Yue
    JOURNAL OF VIBRATION ENGINEERING & TECHNOLOGIES, 2024, 12 (02) : 1429 - 1443
  • [25] Closed-form solutions for the optimal design of lever-arm tuned mass damper inerter (LTMDI)
    Li, Zhenchuan
    Ma, Ruisheng
    Xu, Kun
    Han, Qiang
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2024, 206
  • [26] Tuned-Mass-Damper-Inerter Performance Evaluation and Optimal Design for Transmission Line under Harmonic Excitation
    Liu, Xinpeng
    Yang, Yingwen
    Sun, Yi
    Zhong, Yongli
    Zhou, Lei
    Li, Siyuan
    Wu, Chaoyue
    BUILDINGS, 2022, 12 (04)
  • [27] Optimal design and seismic performance of tuned mass damper inerter (TMDI) for structures with nonlinear base isolation systems
    De Domenico, Dario
    Ricciardi, Giuseppe
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2018, 47 (12): : 2539 - 2560
  • [28] Optimal design and performance analysis of a tuned negative-stiffness inerter mass damper for vibration control systems
    Tai, Yu-ji
    Cheng, Lu-lu
    Liu, Liang-kun
    Bao, Hai-ying
    Wang, Shi-long
    STRUCTURES, 2025, 73
  • [29] Optimal design of tuned mass damper inerter with a Maxwell element for mitigating the vortex-induced vibration in bridges
    Dai, Jun
    Xu, Zhao-Dong
    Gai, Pan-Pan
    Hu, Zhong-Wei
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2021, 148
  • [30] OPTIMAL DESIGN OF TUNED MASS DAMPERS WITH VARIABLE INERTER AND DAMPING
    Chang, Chang-Ching
    Wang, Jer-Fu
    Lin, Chi-Chang
    Lin, Tzu-Ting
    Lin, Chih-Shiuan
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, 2019, VOL 8, 2019,