Dosimetric characteristics of the 192Ir high-dose-rate afterloading brachytherapy source

被引:0
|
作者
Mahdi Sadeghi
Fatemah Taghdiri
Pooneh Saidi
机构
[1] Nuclear Science and Technology Research Institute,Agricultural, Medical, and Industrial Research School
[2] Islamic Azad University,Department of Nuclear Engineering, Science and Research Branch
来源
关键词
Monte Carlo calculation; Brachytherapy; TG-43U1; MCNP5; Ir;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:324 / 329
页数:5
相关论文
共 50 条
  • [21] Monte Carlo dosimetry of a new 192Ir high dose rate brachytherapy source
    Angelopoulos, A
    Baras, P
    Sakelliou, L
    Karaiskos, P
    Sandilos, P
    MEDICAL PHYSICS, 2000, 27 (11) : 2521 - 2527
  • [22] Dosimetric perturbations at high-Z interfaces with high dose rate 192Ir source
    Zhang, Hualin
    Das, Indra J.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (07): : 782 - 790
  • [23] Verification of high dose rate 192Ir source position during brachytherapy treatment
    Batic, M.
    Burger, J.
    Cindro, V.
    Kramberger, G.
    Mandic, I.
    Mikuz, M.
    Studen, A.
    Zavrtanik, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 617 (1-3): : 206 - 208
  • [24] Dosimetric comparison of 60Co and 192Ir high dose rate source used in brachytherapy treatment of cervical cancer
    Shukla, Arvind Kumar
    Jangid, Pawan Kumar
    Rajpurohit, Vikram Singh
    Verma, Atul
    Dangayach, Suresh Kumar
    Gagrani, Vaibhav
    Rathore, Narendra Kumar
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (06) : 1212 - 1215
  • [25] Dosimetric characteristics of 192Ir sources used in interstitial brachytherapy
    Ghiassi-Nejad, M
    Jafarizadeh, M
    Ahmadian-Pour, MR
    Ghahramani, AR
    APPLIED RADIATION AND ISOTOPES, 2001, 55 (02) : 189 - 195
  • [26] Clinical application of the Fricke-glucomannan gel dosimeter for high-dose-rate 192Ir brachytherapy
    Noda, S.
    Suzuki, Y.
    Hoshino, Y.
    Furukawa, S.
    Katoh, H.
    Kurotaki, K.
    Nakano, T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (14): : 3985 - 3993
  • [27] Application of a pelvic phantom in brachytherapy dosimetry for high-dose-rate (HDR) 192Ir source based on Monte Carlo simulations
    Ahn, Woo Sang
    Choi, Wonsik
    Shin, Seong Soo
    Jung, Jinhong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (04) : 557 - 564
  • [28] Application of a pelvic phantom in brachytherapy dosimetry for high-dose-rate (HDR) 192Ir source based on Monte Carlo simulations
    Woo Sang Ahn
    Wonsik Choi
    Seong Soo Shin
    Jinhong Jung
    Journal of the Korean Physical Society, 2014, 65 : 557 - 564
  • [29] Erratum to: Monte Carlo dosimetry of the IRAsource high dose rate 192Ir brachytherapy source
    Akbar Sarabiasl
    Navid Ayoobian
    Hossein Poorbaygi
    Iraj Jabbari
    Mohammad Reza Javanshir
    Australasian Physical & Engineering Sciences in Medicine, 2016, 39 : 591 - 591
  • [30] Quality control of 192Ir High Dose Rate Brachytherapy sources
    Pereira, A
    Pirraco, R
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S136 - S137