Measurement of Backscattered Radiation from Secondary Collimator Jaws into the Beam Monitor Chamber from a Dual Energy Linear Accelerator

被引:0
|
作者
Manickam Ravikumar
Ramamoorthy Ravichandran
机构
[1] Department of Radiation Physics,
[2] Kidwai Memorial Institute of Oncology,undefined
[3] Bangalore,undefined
[4] India,undefined
来源
关键词
Key Words: Monitor chamber; Collimator scatter; Asymmetric fields; Telescopic analysis; Schlüsselwörter: Messkammer; Kollimatorstreuung; Asymmetrische Felder; Teleskopische Analyse;
D O I
暂无
中图分类号
学科分类号
摘要
The photons and electrons backscattered from the upper and lower secondary collimator jaws give rise to a significant increase in the ion charge measured by the monitor chamber, and this increase varies between different accelerators. We have studied the effect of backscatter into the monitor chamber at 6 MV and 18 MV photon energies for the linear accelerator Clinac-1800.
引用
收藏
页码:670 / 675
页数:5
相关论文
共 45 条
  • [31] Beam energy measurement on LINAC-200 accelerator and energy calibration of scintillation detectors by electrons in range from 1 MeV to 25 MeV
    Krmar, M.
    Teterev, Y.
    Belov, A. G.
    Mitrofanov, S.
    Abou El-Azm, S.
    Gostkin, M.
    Kobets, V
    Kruchonak, U.
    Nozdrin, A.
    Porokhovoy, S.
    Demichev, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 935 : 83 - 88
  • [32] Air kerma reference field with high energy photons using a 15 MeV electron beam from a clinical linear accelerator
    Ishii, Junya
    Shimizu, Morihito
    Kato, Masahiro
    Kurosawa, Tadahiro
    Watabe, Hiroshi
    JOURNAL OF RADIOLOGICAL PROTECTION, 2024, 44 (01)
  • [33] Measurement of radiation heating induced by secondary particles from 12-GeV primary proton-beam interactions
    Ohnishi, H
    Yoshimura, K
    Nakamoto, T
    Yamamoto, A
    Ajima, Y
    Aoki, M
    Fukasawa, N
    Ishibashi, K
    Kuno, Y
    Miura, T
    Nakahara, K
    Nosaka, N
    Numajiri, M
    Ogitsu, T
    Sato, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 545 (1-2): : 88 - 96
  • [34] Proposing a novel graphical method to determine effective bremsstrahlung focal spot size and shape of the therapeutic beam from a linear accelerator in radiation therapy
    Shende, Ravindra
    Gupta, Gourav
    Dhoble, S. J.
    Patel, Ganeshkumar
    Dassharma, Ashutosh
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1012
  • [35] Dose Measurements in the Build-Up Region for the Photon Beams from Clinac-1800 Dual Energy Medical Linear Accelerator
    Manickam Ravikumar
    Ramamoorthy Ravichandran
    Strahlentherapie und Onkologie, 2000, 176 : 223 - 228
  • [36] Dose measurements in the build-up region for the photon beams from clinac-1800 dual energy medical linear accelerator
    Ravikumar, M
    Ravichandran, R
    STRAHLENTHERAPIE UND ONKOLOGIE, 2000, 176 (05) : 223 - 228
  • [37] Dose rate and energy distributions of X rays from a linear accelerator at the maze entrance of a radiotherapy room by measurement and Monte Carlo simulation
    Al-Affan, IAM
    Smith, CW
    Morgan, HM
    Lillicrap, SC
    RADIATION PROTECTION DOSIMETRY, 1998, 78 (04) : 273 - 277
  • [38] Finding concealed high atomic numbered materials hidden in cargo containers using dual energy high energy x-rays from a linear accelerator with the unique signature from photofission
    Clayton, James E.
    Bjorkholm, Paul
    SENSORS, AND COMMAND, CONTROL, COMMUNICATIONS, AND INTELLIGENCE (C31)TECHNOLOGIES FOR HOMELAND SECURITY AND HOMELAND DEFENSE V, 2006, 6201
  • [39] On the existence of low-energy photons (<150 keV) in the unflattened x-ray beam from an ordinary radiotherapeutic target in a medical linear accelerator
    Tsechanski, A
    Krutman, Y
    Faermann, S
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (23): : 5629 - 5639
  • [40] Study on the measurement of photo-neutron for15 MV photon beam from medical linear accelerator under different irradiation geometries using passive detectors
    Thekkedath, Siji Cyriac
    Raman, R. Ganapathi
    Musthafa, M. M.
    Bakshi, A. K.
    Pal, Rupali
    Dawn, Sandipan
    Kummali, Abdul Haneefa
    Huilgol, Nagraj G.
    Selvam, T. Palani
    Datta, D.
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2016, 12 (02) : 1060 - 1064