Calibration Transfer between Two Near-Infrared Spectrometers Based on a Wavelet Packet Transform

被引:0
|
作者
Chao Tan
Menglong Li
机构
[1] Sichuan University,College of Chemistry
[2] Yibin University,Department of Chemistry and Chemical Engineering
来源
Analytical Sciences | 2007年 / 23卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A standardization algorithm, called WPTS, which is based on a wavelet packet transform (WPT) and entropy criteria, is proposed to transfer spectra between two near-infrared spectrometers. First, the spectra of the standardization samples measured on both spectrometers are collected and the difference mean spectrum is calculated; then, a wavelet packet transform is performed and a best WPT-tree is generated, of which a node is selected to establish a transfer matrix. Once the transfer matrix has been built, spectra measured on one spectrometer can be successfully transferred to another spectrometer as if they have been measured directly on the latter. By comparison, the proposed WPTS can reach a transfer performance comparable to WTS1, which is the best existing method, and better than WTS2 and classical PDS by a simpler technique of variable selection and lower computational cost of calibration transfer.
引用
收藏
页码:201 / 206
页数:5
相关论文
共 50 条
  • [31] Multi-way based calibration transfer between two Raman spectrometers
    Kompany-Zareh, Mohsen
    van den Berg, Frans
    ANALYST, 2010, 135 (06) : 1382 - 1388
  • [32] Calibration transfer for near-infrared (NIR) spectroscopy based on local preserving projection
    Bin, Jun
    Yan, Xiufang
    Liu, Renxiang
    Kang, Chao
    Chen, Yi
    VIBRATIONAL SPECTROSCOPY, 2023, 126
  • [33] Calibration model transfer for near-infrared spectra based on canonical correlation analysis
    Fan, Wei
    Liang, Yizeng
    Yuan, Dalin
    Wang, Jiajun
    ANALYTICA CHIMICA ACTA, 2008, 623 (01) : 22 - 29
  • [34] Calibration Transfer for Near-Infrared (NIR) Spectroscopy Based on Neighborhood Preserving Embedding
    Chen, Lijuan
    Liu, Dawei
    Zhou, Jiheng
    Bin, Jun
    Li, Zhen
    ANALYTICAL LETTERS, 2021, 54 (06) : 947 - 965
  • [35] Calibration transfer of near infrared spectrometers for the assessment of plasma ethanol precipitation process
    Sun, Zhongyu
    Wang, Jiayue
    Nie, Lei
    Li, Lian
    Cao, Dawei
    Fan, Jiajin
    Wang, Haiyan
    Liu, Ruichen
    Zhang, Yinran
    Zang, Hengchang
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2018, 181 : 64 - 71
  • [36] Wavelet Transform Makes Water an Outstanding Near-Infrared Spectroscopic Probe
    Wang, Mian
    An, Hongle
    Cai, Wensheng
    Shao, Xueguang
    CHEMOSENSORS, 2023, 11 (01)
  • [37] Clustering Analysis of Near-Infrared Spectra of Rhubarb after Wavelet Transform
    Yanfeng TANG
    Zhanzhong HOU
    Zhibao WANG
    Guoqiang FAN
    Medicinal Plant, 2013, (01) : 11 - 13
  • [38] Information Extraction of Near Infrared Spectra for Complex Samples Based on Wavelet Packet Transform and Entropy Theory
    Peng Dan
    Yue Jin-xia
    Bi Yan-lan
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (11) : 3409 - 3413
  • [39] Calibration transfer between miniature photodiode array-based spectrometers in the near infrared assessment of mandarin soluble solids content
    Greensill, CV
    Walsh, KB
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2002, 10 (01) : 27 - 35
  • [40] Continuous Wavelet Transform Combined with Parametric-Free Calibration Enhancement Framework for Calibration of Time-shift Near-infrared Spectra
    Jin, Zhang
    Shi-Zhu, Ye
    Ai-Jing, Wu
    Bo-Yan, Li
    Jie, Li
    You-Guo, Zhan
    Hai-Gen, Peng
    Xing-Yang, Xu
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 50 (09) : 1391 - 1398