Calibration Transfer between Two Near-Infrared Spectrometers Based on a Wavelet Packet Transform

被引:0
|
作者
Chao Tan
Menglong Li
机构
[1] Sichuan University,College of Chemistry
[2] Yibin University,Department of Chemistry and Chemical Engineering
来源
Analytical Sciences | 2007年 / 23卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A standardization algorithm, called WPTS, which is based on a wavelet packet transform (WPT) and entropy criteria, is proposed to transfer spectra between two near-infrared spectrometers. First, the spectra of the standardization samples measured on both spectrometers are collected and the difference mean spectrum is calculated; then, a wavelet packet transform is performed and a best WPT-tree is generated, of which a node is selected to establish a transfer matrix. Once the transfer matrix has been built, spectra measured on one spectrometer can be successfully transferred to another spectrometer as if they have been measured directly on the latter. By comparison, the proposed WPTS can reach a transfer performance comparable to WTS1, which is the best existing method, and better than WTS2 and classical PDS by a simpler technique of variable selection and lower computational cost of calibration transfer.
引用
收藏
页码:201 / 206
页数:5
相关论文
共 50 条
  • [21] COMPARISON OF SPECTRAL RESPONSE OF NEAR-INFRARED SPECTROMETERS USED FOR ROUTINE ANALYSES .2. STUDY OF THE TRANSFER OF CALIBRATION BETWEEN INSTRUMENTS
    DESAINTDO, I
    BERTRAND, D
    ANALUSIS, 1990, 18 (03) : 157 - 161
  • [22] A method for near-infrared spectral calibration of complex plant samples with wavelet transform and elimination of uninformative variables
    Shao, XG
    Wang, F
    Chen, D
    Su, QD
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (05) : 1382 - 1387
  • [23] Calibration transfer of spectra from near infrared spectrometers by Procrustes analysis
    Chu, XL
    Yuan, HF
    Lu, WZ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (01) : 114 - 119
  • [24] Forage calibration transfer from laboratory to portable near infrared spectrometers
    Yang, Xueping
    Cherney, J. H.
    Casler, M. D.
    Berzaghi, Paolo
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2023, 31 (03) : 126 - 140
  • [25] A method for near-infrared spectral calibration of complex plant samples with wavelet transform and elimination of uninformative variables
    Xueguang Shao
    Fang Wang
    Da Chen
    Qingde Su
    Analytical and Bioanalytical Chemistry, 2004, 378 : 1382 - 1387
  • [26] Ultra-high resolution near-infrared spectrum by wavelet packet transform revealing the hydrogen bond interactions
    Han, Li
    Sun, Yan
    Wang, Yan
    Fu, Haohao
    Duan, Chaoshu
    Wang, Mian
    Cai, Wensheng
    Shao, Xueguang
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 289
  • [27] Application of Fourier transform to multivariate calibration of near-infrared data
    Pasti, L
    Jouan-Rimbaud, D
    Massart, DL
    de Noord, OE
    ANALYTICA CHIMICA ACTA, 1998, 364 (1-3) : 253 - 263
  • [28] Transfer of multivariate calibrations between four near-infrared spectrometers using orthogonal signal correction
    Woody, NA
    Feudale, RN
    Myles, AJ
    Brown, SD
    ANALYTICAL CHEMISTRY, 2004, 76 (09) : 2595 - 2600
  • [29] Calibration of a visible and near-infrared portable transfer radiometer
    Biggar, SF
    METROLOGIA, 1998, 35 (04) : 701 - 706
  • [30] Detection and Analysis of Alcohol Near-Infrared Spectrum in Vitro and Vivo Based on Wavelet Transform
    Luo Si-te
    Li Zeng-yong
    Zhang Ming
    Chen Guo-qiang
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (06) : 1541 - 1546