Calibration Transfer between Two Near-Infrared Spectrometers Based on a Wavelet Packet Transform

被引:0
|
作者
Chao Tan
Menglong Li
机构
[1] Sichuan University,College of Chemistry
[2] Yibin University,Department of Chemistry and Chemical Engineering
来源
Analytical Sciences | 2007年 / 23卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A standardization algorithm, called WPTS, which is based on a wavelet packet transform (WPT) and entropy criteria, is proposed to transfer spectra between two near-infrared spectrometers. First, the spectra of the standardization samples measured on both spectrometers are collected and the difference mean spectrum is calculated; then, a wavelet packet transform is performed and a best WPT-tree is generated, of which a node is selected to establish a transfer matrix. Once the transfer matrix has been built, spectra measured on one spectrometer can be successfully transferred to another spectrometer as if they have been measured directly on the latter. By comparison, the proposed WPTS can reach a transfer performance comparable to WTS1, which is the best existing method, and better than WTS2 and classical PDS by a simpler technique of variable selection and lower computational cost of calibration transfer.
引用
收藏
页码:201 / 206
页数:5
相关论文
共 50 条
  • [1] Calibration transfer between two near-infrared spectrometers based on a wavelet packet transform
    Tan, Chao
    Li, Menglong
    ANALYTICAL SCIENCES, 2007, 23 (02) : 201 - 206
  • [2] CALIBRATION TRANSFER AND MEASUREMENT STABILITY OF NEAR-INFRARED SPECTROMETERS
    WANG, YD
    KOWALSKI, BR
    APPLIED SPECTROSCOPY, 1992, 46 (05) : 764 - 771
  • [3] Calibration transfer of near-infrared spectroscopy by canonical correlation analysis coupled with wavelet transform
    Bin, Jun
    Li, Xin
    Fan, Wei
    Zhou, Ji-heng
    Wang, Cheng-wei
    ANALYST, 2017, 142 (12) : 2229 - 2238
  • [4] Calibration transfer of near-infrared spectra based on compression of wavelet coefficients
    Yoon, JG
    Lee, BW
    Han, CH
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2002, 64 (01) : 1 - 14
  • [5] Improved calibration transfer between near-Infrared (NIR) spectrometers using canonical correlation analysis
    Yang, Junxing
    Lou, Xiaoping
    Yang, Hongqi
    Yang, Huibing
    Liu, Chaoying
    Wu, Jingjing
    Bin, Jun
    ANALYTICAL LETTERS, 2019, 52 (14) : 2188 - 2202
  • [6] A PHANTOM FOR THE TESTING AND CALIBRATION OF NEAR-INFRARED SPECTROMETERS
    FIRBANK, M
    DELPY, DT
    PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (09): : 1509 - 1513
  • [7] Quantitative Calibration of Near-Infrared Spectra by Wavelet Packet Transform, Orthogonal Signal Correction and Information Entropy Theory
    Peng, Dan
    Xu, Kexin
    2009 SYMPOSIUM ON PHOTONICS AND OPTOELECTRONICS (SOPO 2009), 2009, : 971 - +
  • [8] Near-infrared calibration transfer for undried whole maize plant between laboratory and on-site spectrometers
    Marchesini, Giorgio
    Serva, Lorenzo
    Garbin, Elisabetta
    Mirisola, Massimo
    Andrighetto, Igino
    ITALIAN JOURNAL OF ANIMAL SCIENCE, 2018, 17 (01) : 66 - 72
  • [9] CALIBRATION TRANSFER BETWEEN NEAR-INFRARED REFLECTANCE SPECTROPHOTOMETERS
    SHENK, JS
    WESTERHAUS, MO
    TEMPLETON, WC
    CROP SCIENCE, 1985, 25 (01) : 159 - 161
  • [10] Comparison of qualitative and quantitative performance of two portable near-infrared spectrometers for intact Rehmanniae Radix and calibration transfer
    Yue, Jianan
    Gao, Lele
    Zhong, Liang
    Huang, Ruiqi
    Yang, Xinya
    Tian, Weilu
    Cao, Guiyun
    Meng, Zhaoqing
    Nie, Lei
    Zang, Hengchang
    MICROCHEMICAL JOURNAL, 2024, 204