Development of a Daily-Treatment Beam-Monitoring System Based Gafchromic EBT3 Film for Pencil-Beam Scanning Proton Therapy

被引:0
|
作者
Seonghoon Jeong
Myonggeun Yoon
Kwangzoo Chung
机构
[1] National Cancer Center,Proton Therapy Center
[2] Korea University,Department of Bio
[3] Sungkyunkwan University,convergence Engineering
来源
关键词
Proton therapy; Pencil-beam scanning; Gafchromic EBT3 film; Daily beam monitoring;
D O I
暂无
中图分类号
学科分类号
摘要
This study describes the development of a simple method to assess inter-fractional deviations of delivered proton beams in treatment rooms. To monitor the treatment beam, we measured the field-by-field beam fluences by attaching the EBT3 film to the snout, followed by a simple constancy check based on comparisons between the reference beam fluences (acquired during the pre-treatment quality assurance process) and the test beam fluences (acquired during treatment). The feasibility of the proposed treatment beam-monitoring system was confirmed by evaluating 12 treatment fields for each of six patients (brain, liver, prostate, lung, cranial and spinal area, and head and neck). The constancy of the treatment beams was verified by using a gamma index analysis to compare three measurements per field with the reference beam fluence. On the basis of the 3%/3 mm criterion, the average gamma-index passing rates for all measurements were over 99.6%. These results suggest that the constancy of fractional proton beams delivered to patients in treatment rooms can be verified with EBT3 film-based proton-beam monitoring system that can be easily attached to the treatment nozzle and is cost effective.
引用
收藏
页码:769 / 773
页数:4
相关论文
共 49 条
  • [31] Evaluation of monte carlo to support commissioning of the treatment planning system of new pencil beam scanning proton therapy facilities
    Botnariuc, D.
    Court, S.
    Lourenco, A.
    Gosling, A.
    Royle, G.
    Hussein, M.
    Rompokos, V
    Veiga, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (04):
  • [32] Feasibility of Pencil Beam Scanning Proton Therapy Treatment Planning with a Dynamic Collimation System in an FDA-Cleared TPS
    Bennett, L.
    Smith, B.
    Flynn, R.
    Hyer, D.
    Wang, D.
    MEDICAL PHYSICS, 2019, 46 (06) : E101 - E101
  • [33] Evaluations of a flat-panel based compact daily quality assurance device for proton pencil beam scanning (PBS) system
    Su, Zhong
    Hsi, Wen
    Forthomme, Julien
    Rossomme, Severine
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 80 : 243 - 250
  • [34] Investigating aperture-based approximations to model a focused dynamic collimation system for pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Smith, Blake R.
    Flynn, Ryan T.
    Hill, Patrick M.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (02)
  • [35] Clinical validation of a GPU-based Monte Carlo dose engine of a commercial treatment planning system for pencil beam scanning proton therapy
    Fracchiolla, Francesco
    Engwall, Erik
    Janson, Martin
    Tamm, Fredrik
    Lorentini, Stefano
    Fellin, Francesco
    Bertolini, Mattia
    Algranati, Carlo
    Righetto, Roberto
    Farace, Paolo
    Amichetti, Maurizio
    Schwarz, Marco
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 88 : 226 - 234
  • [36] Experimental Validation and Calculation Benchmark for a Commercial Monte Carlo Pencil Beam Scanning Proton Therapy Treatment Planning System in Water
    Lin, L.
    Huang, S.
    Kang, M.
    Ainsley, C.
    Hiltunen, P.
    Vanderstraeten, R.
    Lindberg, J.
    Siljamaki, S.
    Wareing, T.
    Davis, I.
    Barnett, A.
    McGhee, J.
    Solberg, T.
    McDonough, J.
    Simone, C., II
    MEDICAL PHYSICS, 2016, 43 (06) : 3497 - 3497
  • [37] Dosimetric and On-treatment Clinical Results of a Volumetric-based Skin-sparing Planning Technique for Patients Treated to the Breast and Chest Wall With Pencil-Beam Scanning Proton Therapy
    Rao, Avani D.
    Goughenour, Alexander
    Kebede, Betelehem
    Bamberger, Caroline
    Maclennan, Grayden
    Castro, Jackeline
    Stephenson, Lisa
    Negussie, Amanuel
    Seracino, Sydney
    Wang, Hongkun
    Hetelekidis, Stella
    Gao, Sarah J.
    Majithia, Lonika
    Chawla, Ashish
    Parniani, Ashkan
    Wang, Peng
    Fan, Jiajin
    ADVANCES IN RADIATION ONCOLOGY, 2025, 10 (02)
  • [38] Stochastic model for predicting the temporal structure of the plan delivery in a synchrotron-based pencil beam scanning proton therapy system
    Burguete, J.
    Garcia-Cardosa, M.
    Antolin, E.
    Aguilar, B.
    Azcona, J. D.
    RADIATION PHYSICS AND CHEMISTRY, 2025, 226
  • [39] Validation of a Commercial Treatment Planning System for Small-Field Patient-Specific Apertures in Pencil Beam Scanning Proton Therapy
    Holmes, J.
    Shen, J.
    Shan, J.
    Wong, W.
    Foote, R.
    Patel, S.
    Bues, M.
    Liu, W.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [40] Dosimetric Study of Adaptive Proton Pencil-Beam Scanning Treatment Plans Using CBCT-Based Synthetic CTs Generated From Commercial Image Information Systems
    Tsai, P.
    Ackerman, C.
    Chen, C. C.
    Zhang, J.
    Zhai, H.
    Yu, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E152 - E152