Comparison of longitudinal geometric measurement in human coronary arteries between frequency-domain optical coherence tomography and intravascular ultrasound

被引:0
|
作者
Yong Liu
Kunihiro Shimamura
Takashi Kubo
Atsuhi Tanaka
Hironori Kitabata
Yasushi Ino
Takashi Tanimoto
Yasutsugu Shiono
Makoto Orii
Takashi Yamano
Tomoyuki Yamaguchi
Kumiko Hirata
Toshio Imanishi
Takashi Akasaka
机构
[1] Wakayama Medical University,Department of Cardiovascular Medicine
关键词
Optical coherence tomography; Intravascular ultrasound; Coronary angiography; Intracoronary imaging;
D O I
暂无
中图分类号
学科分类号
摘要
Previous studies have demonstrated the higher accuracy of frequency-domain optical coherence tomography (FD-OCT) for quantitative measurements in comparison with intravascular ultrasound (IVUS). However, those analyses were based on the cross-sectional images. The aim of this study was to assess the accuracy of FD-OCT for longitudinal geometric measurements of coronary arteries in comparison with IVUS. Between October 2011 and March 2012, we performed prospective FD-OCT and IVUS examinations in consecutive 77 patients who underwent percutaneous coronary intervention with single stent. Regression analysis and Bland–Altman analysis revealed an excellent correlation between the FD-OCT-measured stent lengths and IVUS-measured stent lengths (r = 0.986, p < 0.001; mean difference = −0.51 mm). There was an excellent agreement between the actual stent lengths and the FD-OCT-measured stent lengths (r = 0.993, p < 0.001) as well as between the actual stent lengths and the IVUS-measured stent lengths (r = 0.981, p < 0.001). The difference between the actual stent lengths and the FD-OCT-measured stent lengths was significantly smaller than that between the actual stent lengths and the IVUS-measured stent lengths (0.15 ± 0.68 vs. 0.70 ± 1.15 mm, p < 0.001). Both FD-OCT (mean difference = −0.04 and −0.04 mm, respectively) and IVUS (mean difference = −0.06 and −0.06 mm, respectively) showed an excellent intra-observer and inter-observer reproducibility for the stent length measurements. In conclusion, FD-OCT provides accurate longitudinal measurement with excellent intra-observer and inter-observer reproducibility. FD-OCT might be a reliable technique for longitudinal geometric measurement in human coronary arteries.
引用
收藏
页码:271 / 277
页数:6
相关论文
共 50 条
  • [41] The clinical utility of frequency-domain optical coherence tomography guidance for coronary stent implantation compared with intravasucular ultrasound guidance
    Habara, M.
    Nasu, K.
    Terashima, M.
    Ko, Y.
    Ito, T.
    Kurita, T.
    Kinoshita, Y.
    Tsuchikane, E.
    Katoh, O.
    Suzuki, T.
    EUROPEAN HEART JOURNAL, 2011, 32 : 402 - 402
  • [42] Optical coherence tomography and intravascular ultrasound imaging of bioabsorbable magnesium stent degradation in porcine coronary arteries
    Slottow, Tina L. Pinto
    Pakala, Rajbabu
    Okabe, Teruo
    Hellinga, David
    Lovec, Rachel J.
    Tio, Fermin O.
    Bui, Anh B.
    Waksman, Ron
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2008, 9 (04) : 248 - 254
  • [44] Optical coherence tomography by adopting frequency-domain optical delay line
    Shi, Guo-Hua
    Ding, Zhi-Hua
    Rao, Xue-Jun
    Zhang, Yu-Dong
    Guangdian Gongcheng/Opto-Electronic Engineering, 2006, 33 (10): : 1 - 4
  • [45] Frequency-domain optical coherence tomography system in the terahertz region
    Hideaki Kitahara
    Masahiko Tani
    Masanori Hangyo
    Applied Physics B, 2020, 126
  • [46] Frequency-domain optical coherence tomography system in the terahertz region
    Kitahara, Hideaki
    Tani, Masahiko
    Hangyo, Masanori
    APPLIED PHYSICS B-LASERS AND OPTICS, 2020, 126 (01):
  • [47] Motion artifacts in optical coherence tomography with frequency-domain ranging
    Yun, SH
    Tearney, GJ
    de Boer, JF
    Bouma, BE
    OPTICS EXPRESS, 2004, 12 (13): : 2977 - 2998
  • [48] Advances in Optical Coherence Tomography: Frequency-domain Technology and Applications
    Yun, Seok Hyun
    2007 CONFERENCE ON LASERS & ELECTRO-OPTICS/QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2007), VOLS 1-5, 2007, : 1662 - 1663
  • [49] Comparison of Outcomes in Patients Undergoing Percutaneous Coronary Intervention Using Intravascular Ultrasound or Intravascular Optical Coherence Tomography
    Darmoch, Fahed M.
    Al-Khadra, Yasser
    Pacha, Homam Moussa
    Soud, Mohamad
    Alraies, M. Chadi M.
    CIRCULATION, 2019, 140
  • [50] Comparison of Outcomes in Patients Undergoing Percutaneous Coronary Intervention Using Intravascular Ultrasound or Intravascular Optical Coherence Tomography
    Darmoch, Fahed
    Al-Khadra, Yasser
    Pacha, Homam Moussa
    Soud, Mohamad
    Alraies, M. Chadi