Comparison of longitudinal geometric measurement in human coronary arteries between frequency-domain optical coherence tomography and intravascular ultrasound

被引:0
|
作者
Yong Liu
Kunihiro Shimamura
Takashi Kubo
Atsuhi Tanaka
Hironori Kitabata
Yasushi Ino
Takashi Tanimoto
Yasutsugu Shiono
Makoto Orii
Takashi Yamano
Tomoyuki Yamaguchi
Kumiko Hirata
Toshio Imanishi
Takashi Akasaka
机构
[1] Wakayama Medical University,Department of Cardiovascular Medicine
关键词
Optical coherence tomography; Intravascular ultrasound; Coronary angiography; Intracoronary imaging;
D O I
暂无
中图分类号
学科分类号
摘要
Previous studies have demonstrated the higher accuracy of frequency-domain optical coherence tomography (FD-OCT) for quantitative measurements in comparison with intravascular ultrasound (IVUS). However, those analyses were based on the cross-sectional images. The aim of this study was to assess the accuracy of FD-OCT for longitudinal geometric measurements of coronary arteries in comparison with IVUS. Between October 2011 and March 2012, we performed prospective FD-OCT and IVUS examinations in consecutive 77 patients who underwent percutaneous coronary intervention with single stent. Regression analysis and Bland–Altman analysis revealed an excellent correlation between the FD-OCT-measured stent lengths and IVUS-measured stent lengths (r = 0.986, p < 0.001; mean difference = −0.51 mm). There was an excellent agreement between the actual stent lengths and the FD-OCT-measured stent lengths (r = 0.993, p < 0.001) as well as between the actual stent lengths and the IVUS-measured stent lengths (r = 0.981, p < 0.001). The difference between the actual stent lengths and the FD-OCT-measured stent lengths was significantly smaller than that between the actual stent lengths and the IVUS-measured stent lengths (0.15 ± 0.68 vs. 0.70 ± 1.15 mm, p < 0.001). Both FD-OCT (mean difference = −0.04 and −0.04 mm, respectively) and IVUS (mean difference = −0.06 and −0.06 mm, respectively) showed an excellent intra-observer and inter-observer reproducibility for the stent length measurements. In conclusion, FD-OCT provides accurate longitudinal measurement with excellent intra-observer and inter-observer reproducibility. FD-OCT might be a reliable technique for longitudinal geometric measurement in human coronary arteries.
引用
收藏
页码:271 / 277
页数:6
相关论文
共 50 条
  • [31] Intravascular ultrasound and optical coherence tomography imaging of coronary atherosclerosis
    Costopoulos, Charis
    Brown, Adam J.
    Teng, Zhongzhao
    Hoole, Stephen P.
    West, Nick E. J.
    Samady, Habib
    Bennett, Martin R.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (01): : 189 - 200
  • [32] Intravascular ultrasound and optical coherence tomography imaging of coronary atherosclerosis
    Charis Costopoulos
    Adam J. Brown
    Zhongzhao Teng
    Stephen P. Hoole
    Nick E. J. West
    Habib Samady
    Martin R. Bennett
    The International Journal of Cardiovascular Imaging, 2016, 32 : 189 - 200
  • [33] Comparison of Optical Coherence Tomography and Intravascular Ultrasound Images in the Coronary Lumen Diameter and Area
    Mizutani, Satoshi
    Nagai, Hiroyuki
    Okamura, Atsunori
    Date, Motoo
    Higuchi, Yoshinaru
    Ozawa, Makito
    Shibuya, Masahiko
    Iwakura, Katsumi
    Fujii, Kenshi
    Okada, Yuusuke
    Iho, Junichi
    Morishige, Miho
    Takayama, Yuuki
    Kawamura, Katsutoshi
    Kosaka, Yuki
    Sato, Youichi
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 105 (9A): : 59B - 60B
  • [34] Identification of vulnerable plaques by optical coherence tomography; a comparison with intravascular ultrasound and coronary angioscopy
    Takarada, S.
    Kubo, T.
    Yamano, T.
    Matsuo, Y.
    Masho, T.
    Hayashi, Y.
    Tomobuchi, Y.
    Akasaka, T.
    EUROPEAN HEART JOURNAL, 2006, 27 : 582 - 582
  • [35] Comparison between a time-domain and a frequency-domain system for optical tomography
    Nissila, Ilkka
    Lipiainen, Lauri
    Hebden, Jeremy C.
    Katila, Toivo
    Jennions, David
    Heino, Jenni
    Schweiger, Martin
    Kotilahti, Kalle
    Noponen, Tommi
    Gibson, Adam
    Jarvenpaa, Seppo
    JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (06)
  • [36] Feasibility of Frequency-Domain Optical Coherence Tomography for Coronary Stent Imaging: A Matter of Definitions
    Nammas, Wail
    JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (10): : A46 - A46
  • [37] Letter by Garcia-Garcia et al Regarding Article, "Impact of Frequency-Domain Optical Coherence Tomography Guidance for Optimal Coronary Stent Implantation in Comparison With Intravascular Ultrasound Guidance"
    Garcia-Garcia, Hector M.
    Onuma, Yoshinobu
    Serruys, Patrick W.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (04) : E59 - E59
  • [38] Intravascular imaging in acute coronary syndrome Intravascular ultrasound and optical coherence tomography
    Mrevlje, B.
    Legutko, J.
    Tillwich, F.
    Jakala, J.
    Dudek, D.
    Noc, M.
    Rzeszutko, L.
    Kleczynski, P.
    Birkemeyer, R.
    Aboukoura, M.
    Nienaber, C. A.
    KARDIOLOGE, 2015, 9 (01): : 47 - 53
  • [39] Optical coherence tomography of coronary arteries - a novel intravascular imaging modality
    Mrevlje, B.
    Legutko, J.
    Jakala, J.
    Noc, M.
    Dudek, D.
    Birkemeyer, R.
    Aboukoura, M.
    Nienaber, C.
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2014, 139 (39) : 1941 - 1946
  • [40] Correlation between high frequency intravascular ultrasound and histomorphology in human coronary arteries
    Prati, F
    Arbustini, E
    Labellarte, A
    Dal Bello, B
    Sommariva, L
    Mallus, MT
    Pagano, A
    Boccanelli, A
    HEART, 2001, 85 (05) : 567 - 570