Magnitude subtraction vs. complex subtraction in dynamic contrast-enhanced 3D-MR angiography: Basic experiments and clinical evaluation

被引:0
|
作者
Naganawa, S [1 ]
Ito, T [1 ]
Iwayama, E [1 ]
Fukatsu, H [1 ]
Ishiguchi, T [1 ]
Ishigaki, T [1 ]
Ichinose, N [1 ]
机构
[1] Nagoya Univ, Sch Med, Dept Radiol, Showa Ku, Nagoya, Aichi 4668550, Japan
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1999年 / 10卷 / 05期
关键词
magnetic resonance angiography; contrast enhancement; three-dimensional; complex subtraction; magnitude subtraction;
D O I
10.1002/(SICI)1522-2586(199911)10:5<813::AID-JMRI28>3.0.CO;2-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnitude subtraction and complex subtraction in dynamic contrast-enhanced three-dimensional magnetic resonance (3D-MR) angiography were compared using a phantom and 23 human subjects. In phantom studies, complex subtraction showed far better performance than magnitude subtraction, especially for longer echo times, with thicker slices, and without fat suppression. With complex subtraction, non-fat-suppressed studies showed contrast-to-noise ratios comparable to those in fat-suppressed studies. In human subjects, complex subtraction was superior to magnitude subtraction in 9 subjects, but comparable to magnitude subtraction in 14 subjects, There were no cases in which magnitude subtraction was superior to complex subtraction. Although the differences observed in human studies when complex subtraction was applied with thinner slices, shorter echo times, and the fat-suppression technique were not as pronounced as those seen in phantom studies, complex subtraction should be performed in dynamic contrast-enhanced 3D-MR angiography because there are no drawbacks in complex subtraction, Further research is necessary to assess the feasibility of dynamic contrast-enhanced 3D-MR angiography without fat suppression in human subjects using complex subtraction. as suggested by the results of phantom studies, If it is found to be feasible, dynamic contrast-enhanced ED-MR angiography without fat suppression using complex subtraction may prove to be a robust technique that eliminates the need for shimming and can reduce the acquisition time. (C) 1999 Wiley-Liss, Inc.
引用
收藏
页码:813 / 820
页数:8
相关论文
共 50 条
  • [41] 3D Contrast-enhanced MR angiography
    Zhang, HongLei
    Maki, Jeffrey H.
    Prince, Martin R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (01) : 13 - 25
  • [42] Diabetes and peripheral arterial occlusive disease: Prospective comparison of a contrast-enhanced subtraction 3D-MR-angiography with conventional DSA
    Kreitner, KF
    Kalden, P
    Neufang, A
    Dueber, C
    Laub, GA
    Krummenauer, F
    RADIOLOGY, 1998, 209P : 456 - 456
  • [43] Contrast-enhanced MR angiography vs intra-arterial digital subtraction angiography for carotid imaging: activity-based cost analysis
    Jean Marie U-King-Im
    William Hollingworth
    Rikin A. Trivedi
    Justin J. Cross
    Nicholas J. Higgins
    Martin J. Graves
    Peter J. Kirkpatrick
    Nagui M. Antoun
    Jonathan H. Gillard
    European Radiology, 2004, 14 : 730 - 735
  • [44] Contrast-enhanced MR angiography vs intra-arterial digital subtraction angiography for carotid imaging: activity-based cost analysis
    U-King-Im, JM
    Hollingworth, W
    Trivedi, RA
    Cross, JJ
    Higgins, NJ
    Graves, MJ
    Kirkpatrick, PJ
    Antoun, NM
    Gillard, JH
    EUROPEAN RADIOLOGY, 2004, 14 (04) : 730 - 735
  • [45] 4D Radial Acquisition Contrast-Enhanced MR Angiography and Intracranial Arteriovenous Malformations Quickly Approaching Digital Subtraction Angiography
    Eddleman, Christopher S.
    Jeong, Hyun J.
    Hurley, Michael C.
    Zuehlsdorff, Sven
    Dabus, Guilherme
    Getch, Christopher G.
    Batjer, H. Hunt
    Bendok, Bernard R.
    Carroll, Timothy J.
    STROKE, 2009, 40 (08) : 2749 - 2753
  • [46] Multiphase, contrast-enhanced 3D-MR angiography for morphological and functional focal lesion detection: initial results
    Hawighorst, H
    Schoenberg, SO
    Schlemmer, HP
    Hansmann, J
    van Kaick, G
    RADIOLOGE, 1999, 39 (08): : 671 - 677
  • [47] Clinical usefulness of contrast enhanced 3D-MR angiography using automated stepping table method
    Kubo, H
    Sakuma, H
    Katoh, N
    Maki, H
    Asanuma, G
    Araki, A
    Takeda, K
    ULTRAFAST MAGNETIC RESONANCE IMAGING IN MEDICINE, 1999, 1192 : 135 - 137
  • [48] Contrast-enhanced multi-phasic MR angiography for the abdomen: Comparison of digital subtraction and nonsubtraction techniques
    Ryeom, H
    Lee, HJ
    Chang, Y
    Lee, JJ
    Lee, SK
    Kim, Y
    RADIOLOGY, 2000, 217 : 418 - 418
  • [49] Characterization of aneurysm remnants after endovascular treatment: contrast-enhanced MR angiography versus catheter digital subtraction angiography
    Agid, R.
    Willinsky, R. A.
    Lee, S. -K.
    TerBrugge, K. G.
    Farb, R. I.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (08) : 1570 - 1574
  • [50] Comparison of contrast-enhanced multi-station MR angiography and digital subtraction angiography of the lower extremity arterial disease
    Burbelko, Mykhaylo
    Augsten, Michael
    Kalinowski, Marc O.
    Heverhagen, Johannes T.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (06) : 1427 - 1435