Magnitude subtraction vs. complex subtraction in dynamic contrast-enhanced 3D-MR angiography: Basic experiments and clinical evaluation

被引:0
|
作者
Naganawa, S [1 ]
Ito, T [1 ]
Iwayama, E [1 ]
Fukatsu, H [1 ]
Ishiguchi, T [1 ]
Ishigaki, T [1 ]
Ichinose, N [1 ]
机构
[1] Nagoya Univ, Sch Med, Dept Radiol, Showa Ku, Nagoya, Aichi 4668550, Japan
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1999年 / 10卷 / 05期
关键词
magnetic resonance angiography; contrast enhancement; three-dimensional; complex subtraction; magnitude subtraction;
D O I
10.1002/(SICI)1522-2586(199911)10:5<813::AID-JMRI28>3.0.CO;2-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnitude subtraction and complex subtraction in dynamic contrast-enhanced three-dimensional magnetic resonance (3D-MR) angiography were compared using a phantom and 23 human subjects. In phantom studies, complex subtraction showed far better performance than magnitude subtraction, especially for longer echo times, with thicker slices, and without fat suppression. With complex subtraction, non-fat-suppressed studies showed contrast-to-noise ratios comparable to those in fat-suppressed studies. In human subjects, complex subtraction was superior to magnitude subtraction in 9 subjects, but comparable to magnitude subtraction in 14 subjects, There were no cases in which magnitude subtraction was superior to complex subtraction. Although the differences observed in human studies when complex subtraction was applied with thinner slices, shorter echo times, and the fat-suppression technique were not as pronounced as those seen in phantom studies, complex subtraction should be performed in dynamic contrast-enhanced 3D-MR angiography because there are no drawbacks in complex subtraction, Further research is necessary to assess the feasibility of dynamic contrast-enhanced 3D-MR angiography without fat suppression in human subjects using complex subtraction. as suggested by the results of phantom studies, If it is found to be feasible, dynamic contrast-enhanced ED-MR angiography without fat suppression using complex subtraction may prove to be a robust technique that eliminates the need for shimming and can reduce the acquisition time. (C) 1999 Wiley-Liss, Inc.
引用
收藏
页码:813 / 820
页数:8
相关论文
共 50 条
  • [31] Aortoiliac and lower extremity arteries: Comparison of three-dimensional dynamic contrast-enhanced subtraction MR angiography and conventional angiography
    Sueyoshi, E
    Sakamoto, I
    Matsuoka, Y
    Ogawa, Y
    Hayashi, H
    Hashmi, R
    Hayashi, K
    RADIOLOGY, 1999, 210 (03) : 683 - 688
  • [32] Clustered breast microcalcifications: Evaluation by dynamic contrast-enhanced subtraction MRI
    Gilles, R
    Meunier, M
    Lucidarme, O
    Zafrani, B
    Guinebretiere, JM
    Tardivon, AA
    LeGal, M
    Vanel, D
    Neuenschwander, S
    Arriagada, R
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (01) : 9 - 14
  • [33] 3D-GD-DTPA MR ANGIOGRAPHY OF CEREBRAL BLOOD-VESSELS - A COMPARISON WITH CONVENTIONAL 3D-MR SUBTRACTION ANGIOGRAPHY
    SEIDERER, M
    BAUER, WM
    VILLRINGER, A
    EINHAUPL, K
    LAUB, G
    NUKLEARMEDIZINER, 1990, 13 (04): : 221 - 229
  • [34] Internal carotid artery stenosis: Accuracy of subjective visual impression for evaluation with digital subtraction angiography and contrast-enhanced MR angiography
    U-King-Im, Jean Marie
    Graves, Martin J.
    Cross, Justin J.
    Higgins, Nicholas J.
    Wat, Josephine
    Trivedi, Rikin A.
    Tang, Tjun
    Howarth, Simon P. S.
    Kirkpatrick, Peter J.
    Antoun, Nagui M.
    Gillard, Jonathan H.
    RADIOLOGY, 2007, 244 (01) : 213 - 222
  • [35] Optimized Density-Weighted Imaging for Dynamic Contrast-Enhanced 3D-MR Mammography
    Gutberlet, Marcel
    Roth, Anne
    Hahn, Dietbert
    Koestler, Herbert
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (02) : 328 - 339
  • [36] Evaluation of abdominal aortic aneurysm for stent-grafting: Contrast-enhanced 3D-TOF MR angiography versus 3D CT angiography versus digital subtraction angiography
    Thurnher, SA
    Dorffner, R
    Thurnher, MM
    Kretschmer, G
    Polterauer, P
    Lammer, J
    RADIOLOGY, 1997, 205 : 1564 - 1564
  • [37] Detection of thrombosis in the portal venous system: Comparison of contrast-enhanced MR angiography with intraarterial digital subtraction angiography
    Kreft, B
    Strunk, H
    Flacke, S
    Wolff, M
    Conrad, R
    Gieseke, J
    Pauleit, D
    Bachmann, R
    Hirner, A
    Schild, HH
    RADIOLOGY, 2000, 216 (01) : 86 - 92
  • [38] Hemodialysis access imaging: Comparison of flow-interrupted contrast-enhanced MR angiography and digital subtraction angiography
    Smits, JHM
    Bos, C
    Elgersma, OEH
    van der Mark, WAMA
    Blankestijn, PJ
    Bakker, CJG
    Zijlstra, JJ
    Kalmijn, S
    Mali, WPTM
    RADIOLOGY, 2002, 225 (03) : 829 - 834
  • [39] Prospective evaluation of carotid artery stenosis:: Elliptic centric contrast-enhanced MR angiography and spiral CT angiography compared with digital subtraction angiography
    Alvarez-Linera, J
    Benito-León, J
    Escribano, J
    Campollo, J
    Gesto, R
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2003, 24 (05) : 1012 - 1019
  • [40] High Spatial and Temporal Resolution Dynamic Contrast-Enhanced Magnetic Resonance Angiography Using Compressed Sensing with Magnitude Image Subtraction
    Rapacchi, Stanislas
    Han, Fei
    Natsuaki, Yutaka
    Kroeker, Randall
    Plotnik, Adam
    Lehrman, Evan
    Sayre, James
    Laub, Gerhard
    Finn, J. Paul
    Hu, Peng
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (05) : 1771 - 1783