The effect of the fluence-to-dose conversion coefficients upon the dose estimation to cosmic radiation

被引:0
|
作者
Mares, V [1 ]
Schraube, H [1 ]
机构
[1] Univ Munich, Inst Radiobiol, D-80336 Munich, Germany
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The MCNPX Monte Carlo code of Los Alamos National Laboratory was employed to calculate the organ doses in the anthropomorphic phantoms ADAM and EVA irradiated by monoenergetic fields of neutrons, protons, electrons, photons, charged pions and muons especially in the energy range of practical interest for air crew dose assessment. From the weighted organ doses the fluence-to-effective dose conversion coefficients were calculated according to ICRP recommendations. Using this consistent set of conversion coefficients along with the particle spectra for the specific geographic position and altitude the dose components can be determined to which an individual is exposed along an aviation route. The effect of the different fluence-to-dose conversion coefficients used for the dose estimation to cosmic radiations is discussed.
引用
收藏
页码:257 / 278
页数:22
相关论文
共 50 条
  • [41] Electron fluence correction factors for conversion of dose in plastic to dose in water
    Ding, GX
    Rogers, DWO
    Cygler, JE
    Mackie, TR
    MEDICAL PHYSICS, 1997, 24 (02) : 161 - 176
  • [42] IMPLEMENTATION OF ICRP 116 DOSE CONVERSION COEFFICIENTS FOR RECONSTRUCTING ORGAN DOSE IN A RADIATION COMPENSATION PROGRAM
    Taulbee, Timothy D.
    McCartney, Keith A.
    Traub, Richard
    Smith, Matthew H.
    Neton, James W.
    RADIATION PROTECTION DOSIMETRY, 2017, 173 (1-3) : 131 - 137
  • [43] Fluence-to-effective dose conversion coefficients for high-energy radiations calculated with MCNPX
    Sutton, MR
    Hertel, NE
    Waters, LS
    SHIELDING ASPECTS OF ACCELERATORS, TARGETS AND IRRADIATION FACILITIES, 2001, : 297 - 311
  • [44] Conversion coefficients from fluence to effective dose for heavy ions with energies up to 3 GeV/A
    Sato, T
    Tsuda, S
    Sakamoto, Y
    Yamaguchi, Y
    Niita, K
    RADIATION PROTECTION DOSIMETRY, 2003, 106 (02) : 137 - 144
  • [45] Fluence to effective dose conversion coefficients for electrons with energy from 1 MeV to 100 GeV
    Tsuda, S
    Endo, A
    Yamaguchi, Y
    Sato, O
    RADIATION PROTECTION DOSIMETRY, 2001, 95 (01) : 5 - 16
  • [46] AIR DOSE, TISSUE DOSE, AND DEPTH DOSE FOR THE PRIMARY COSMIC RADIATION
    SCHAEFER, HJ
    RADIATION RESEARCH, 1956, 5 (05) : 594 - 594
  • [47] Conversion coefficients for the estimation of effective dose in cone-beam CT
    Kim, Dong-Soo
    Rashsuren, Oyuntugs
    Kim, Eun-Kyung
    IMAGING SCIENCE IN DENTISTRY, 2014, 44 (01) : 21 - 29
  • [48] Feasibility Study of the Fluence-to-Dose Network (FDNet) for Patient-Specific IMRT Quality Assurance
    Wonjoong Cheon
    Sung Jin Kim
    Ui-Jung Hwang
    Byung Jun Min
    Youngyih Han
    Journal of the Korean Physical Society, 2019, 75 : 724 - 734
  • [49] An algorithm for estimation of cosmic radiation effective dose at civil aviation altitude
    Feng Yingjin
    Chen Weiru
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 3640 - 3643
  • [50] Conversion Coefficients of Local Skin Absorbed Dose per Fluence for Monoenergetic Electrons and Positrons: An Analytical Approach
    Hassan Al Kanti
    O. El Hajjaji
    T. El Bardouni
    Moscow University Physics Bulletin, 2021, 76 : S26 - S29