The effect of the fluence-to-dose conversion coefficients upon the dose estimation to cosmic radiation

被引:0
|
作者
Mares, V [1 ]
Schraube, H [1 ]
机构
[1] Univ Munich, Inst Radiobiol, D-80336 Munich, Germany
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The MCNPX Monte Carlo code of Los Alamos National Laboratory was employed to calculate the organ doses in the anthropomorphic phantoms ADAM and EVA irradiated by monoenergetic fields of neutrons, protons, electrons, photons, charged pions and muons especially in the energy range of practical interest for air crew dose assessment. From the weighted organ doses the fluence-to-effective dose conversion coefficients were calculated according to ICRP recommendations. Using this consistent set of conversion coefficients along with the particle spectra for the specific geographic position and altitude the dose components can be determined to which an individual is exposed along an aviation route. The effect of the different fluence-to-dose conversion coefficients used for the dose estimation to cosmic radiations is discussed.
引用
收藏
页码:257 / 278
页数:22
相关论文
共 50 条
  • [31] THE DETERMINATION OF NEUTRON FLUENCE TO ABSORBED DOSE CONVERSION COEFFICIENTS AND RELATIVE BIOLOGICAL EFFECT BASED ON MICRODOSIMETRY MEASUREMENTS
    Zhang, Weihua
    Li, Chunjuan
    Zou, Yisheng
    Liu, Yina
    Luo, Hailong
    RADIATION PROTECTION DOSIMETRY, 2019, 187 (02) : 262 - 267
  • [32] Fluence to effective dose and effective dose equivalent conversion coefficients for electrons from 5 MeV to 10 GeV
    Ferrari, A
    Pelliccioni, M
    Pillon, M
    RADIATION PROTECTION DOSIMETRY, 1997, 69 (02) : 97 - 104
  • [33] Fluence to effective dose and effective dose equivalent conversion coefficients for photons from 50 keV to 10 GeV
    Ferrari, A
    Pelliccioni, M
    Pillon, M
    RADIATION PROTECTION DOSIMETRY, 1996, 67 (04) : 245 - 251
  • [34] Fluence to dose equivalent conversion data and radiation weighting factors for high energy radiation
    Pelliccioni, M
    RADIATION PROTECTION DOSIMETRY, 1998, 77 (03) : 159 - 170
  • [35] CALCULATED FLUENCE-TO-DIRECTIONAL AND PERSONAL DOSE-EQUIVALENT CONVERSION COEFFICIENTS FOR NEUTRONS
    SIEBERT, BRL
    SCHUHMACHER, H
    RADIATION PROTECTION DOSIMETRY, 1994, 54 (3-4) : 231 - 238
  • [36] Assessment of neutron fluence to organ dose conversion coefficients in the ORNL analytical adult phantom
    Hakimabad, H. Miri
    Motavalli, L. Rafat
    Shahri, K. Karimi
    JOURNAL OF RADIOLOGICAL PROTECTION, 2009, 29 (01) : 51 - 60
  • [37] Fluence to effective dose conversion coefficients for protons from 5 MeV to 10 TeV
    Ferrari, A
    Pelliccioni, M
    Pillon, M
    RADIATION PROTECTION DOSIMETRY, 1997, 71 (02) : 85 - 91
  • [38] Calculation of dose conversion coefficients for radiation workers in various postures
    Kim, Min Chae
    Kim, Hyoungtaek
    Han, Heagin
    Choi, Yoomi
    Kim, Sora
    Lee, Jungil
    Min, Byung Il
    Suh, Kyungsuk
    Kim, Chan Hyeong
    RADIATION PHYSICS AND CHEMISTRY, 2025, 229
  • [39] A new method of estimation of dose conversion coefficients for aquatic biota
    Li, Yang
    Li, Jiangguo
    Wang, Huijuan
    Wang, Aijun
    JOURNAL OF RADIOLOGICAL PROTECTION, 2017, 37 (01) : 31 - 42
  • [40] Computed Tomography Dose in Paediatric Care: Simple Dose Estimation Using Dose Length Product Conversion Coefficients
    Tap, Nor Hanani Mohd
    Sidek, Mohamed Ariff Jaafar
    Ridzwan, Siti Farizwana Mohd
    Selvarajah, S. Elavarasi
    Zaki, Faizah Mohd
    Hamid, Hamzaini Abdul
    MALAYSIAN JOURNAL OF MEDICAL SCIENCES, 2018, 25 (04): : 82 - 91