Motion Compensation for Ultrasound Thermal Imaging Using Motion-Mapped Reference Model: An in vivo Mouse Study

被引:13
|
作者
Seo, Joonho [1 ]
Kim, Sun Kwon [1 ]
Kim, Young-sun [2 ,3 ]
Choi, Kiwan [4 ]
Kong, Dong Geon [4 ]
Bang, Won-Chul [1 ]
机构
[1] Samsung Adv Inst Technol Samsung Elect, Seoul, South Korea
[2] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul, South Korea
[3] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Ctr Imaging Sci, Seoul, South Korea
[4] Hlth & Med Equipment Samsung Elect, Seoul, South Korea
关键词
In vivo mouse experiment; motion compensation; ultrasound based thermal imaging; INDUCED ECHO-STRAIN; TEMPERATURE ESTIMATION; BACKSCATTERED ENERGY; VITRO; DEPENDENCE;
D O I
10.1109/TBME.2014.2325070
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ultrasound (US)-based thermal imaging is very sensitive to tissue motion, which is a major obstacle to apply US temperature monitoring to noninvasive thermal therapies of in vivo subjects. In this study, we aim to develop a motion compensation method for stable US thermal imaging in in vivo subjects. Based on the assumption that the major tissue motion is approximately periodic caused by respiration, we propose a motion compensation method for change in backscattered energy (CBE) with multiple reference frames. Among the reference frames, the most similar reference to the current frame is selected to subtract the respiratory-induced motions. Since exhaustive reference searching in all stored reference frames can impede real-time thermal imaging, we improve the reference searching by using amotion-mapped reference model. We tested our method in six tumor-bearing mice with high intensity focused ultrasound (HIFU) sonication in the tumor volume until the temperature had increased by 7 degrees C. The proposed motion compensation was evaluated by root-mean-square-error (RMSE) analysis between the estimated temperature by CBE and the measured temperature by thermocouple. As a result, the mean +/- SD RMSE in the heating range was 1.1 +/- 0.1 degrees C with the proposed method, while the corresponding result without motion compensation was 4.3 +/- 2.6 degrees C. In addition, with the idea of motion-mapped reference frame, total processing time to produce a frame of thermal image was reduced in comparison with the exhaustive reference searching, which enabled themotioncompensated thermal imaging in 15 frames per second with 150 reference frames under 50% HIFU duty ratio.
引用
收藏
页码:2669 / 2678
页数:10
相关论文
共 50 条
  • [41] DEVELOPMENT AND VALIDATION OF A METHOD TO MEASURE LUMBOSACRAL MOTION USING ULTRASOUND IMAGING
    van den Hoorn, Wolbert
    Coppieters, Michel W.
    van Dieen, Jaap H.
    Hodges, Paul W.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (05): : 1221 - 1229
  • [42] Higher-Order Motion-Compensation for In Vivo Cardiac Diffusion Tensor Imaging in Rats
    Welsh, Christopher L.
    DiBella, Edward V. R.
    Hsu, Edward W.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (09) : 1843 - 1853
  • [43] In Vivo Endoluminal Ultrasound Biomicroscopic Imaging in a Mouse Model of Colorectal Cancer
    Alves, Kelly Z.
    Soletti, Rossana C.
    de Britt, Marcelo A. P.
    de Matos, Dyanna G.
    Soldan, Monica
    Borges, Helena L.
    Machado, Joao C.
    ACADEMIC RADIOLOGY, 2013, 20 (01) : 90 - 98
  • [44] Motion-Corrected Echo Decorrelation Imaging of In Vivo Focused and Bulk Ultrasound Ablation in a Rabbit Liver Cancer Model
    Fosnight, Tyler R.
    Hooi, Fong Ming
    Keil, Ryan D.
    Subramanian, Swetha
    Barthe, Peter G.
    Wang, Yang
    Ren, Xiaoping
    Ahmad, Syed
    Rao, Marepalli B.
    Mast, T. Douglas
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 2161 - 2164
  • [45] Motion compensation in ISAR imaging using the registration-restoration-fusion approach
    Thayaparan, T.
    Lampropoulos, G.
    Stankovic, L.
    IET SIGNAL PROCESSING, 2008, 2 (03) : 223 - 236
  • [46] Model based respiratory motion compensation using static PET acquisition
    Qiao, F.
    Pan, T.
    Clark, J.
    Mawlawi, O.
    MEDICAL PHYSICS, 2007, 34 (06) : 2596 - 2596
  • [47] Cardiac Motion Estimation Using Ultrafast Ultrasound Imaging Tested in a Finite Element Model of Cardiac Mechanics
    Nillesen, Maartje M.
    Saris, Anne E. C. M.
    Hansen, Hendrik H. G.
    Fekkes, Stein
    van Slochteren, Frebus J.
    Bovendeerd, Peter H. M.
    De Korte, Chris L.
    FUNCTIONAL IMAGING AND MODELING OF THE HEART (FIMH 2015), 2015, 9126 : 207 - 214
  • [48] Compensation technique for the intrinsic error in ultrasound motion estimation using a speckle tracking method
    Taki, Hirofumi
    Yamakawa, Makoto
    Shiina, Tsuyoshi
    Sato, Toru
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2015, 54 (07)
  • [49] High-resolution motion compensation for brain PET imaging using real-time electromagnetic motion tracking
    Tan, Wanbin
    Wang, Zipai
    Zeng, Xinjie
    Boccia, Anthony
    Wang, Xiuyuan
    Li, Yixin
    Li, Yi
    Fung, Edward K.
    Qi, Jinyi
    Zeng, Tianyi
    Gupta, Ajay
    Goldan, Amir H.
    MEDICAL PHYSICS, 2024, : 201 - 218
  • [50] Measurement of in-vivo Patella Kinematics Using Motion Analysis and Ultrasound (MAUS)
    Monk, A. P.
    Chen, M.
    Mellon, S.
    Gibbons, C. L. M. H.
    Beard, D. J.
    Gill, H. S.
    Murray, D. W.
    2013 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS PROCEEDINGS (MEMEA), 2013, : 257 - 260