Motion Compensation for Ultrasound Thermal Imaging Using Motion-Mapped Reference Model: An in vivo Mouse Study

被引:13
|
作者
Seo, Joonho [1 ]
Kim, Sun Kwon [1 ]
Kim, Young-sun [2 ,3 ]
Choi, Kiwan [4 ]
Kong, Dong Geon [4 ]
Bang, Won-Chul [1 ]
机构
[1] Samsung Adv Inst Technol Samsung Elect, Seoul, South Korea
[2] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul, South Korea
[3] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Ctr Imaging Sci, Seoul, South Korea
[4] Hlth & Med Equipment Samsung Elect, Seoul, South Korea
关键词
In vivo mouse experiment; motion compensation; ultrasound based thermal imaging; INDUCED ECHO-STRAIN; TEMPERATURE ESTIMATION; BACKSCATTERED ENERGY; VITRO; DEPENDENCE;
D O I
10.1109/TBME.2014.2325070
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ultrasound (US)-based thermal imaging is very sensitive to tissue motion, which is a major obstacle to apply US temperature monitoring to noninvasive thermal therapies of in vivo subjects. In this study, we aim to develop a motion compensation method for stable US thermal imaging in in vivo subjects. Based on the assumption that the major tissue motion is approximately periodic caused by respiration, we propose a motion compensation method for change in backscattered energy (CBE) with multiple reference frames. Among the reference frames, the most similar reference to the current frame is selected to subtract the respiratory-induced motions. Since exhaustive reference searching in all stored reference frames can impede real-time thermal imaging, we improve the reference searching by using amotion-mapped reference model. We tested our method in six tumor-bearing mice with high intensity focused ultrasound (HIFU) sonication in the tumor volume until the temperature had increased by 7 degrees C. The proposed motion compensation was evaluated by root-mean-square-error (RMSE) analysis between the estimated temperature by CBE and the measured temperature by thermocouple. As a result, the mean +/- SD RMSE in the heating range was 1.1 +/- 0.1 degrees C with the proposed method, while the corresponding result without motion compensation was 4.3 +/- 2.6 degrees C. In addition, with the idea of motion-mapped reference frame, total processing time to produce a frame of thermal image was reduced in comparison with the exhaustive reference searching, which enabled themotioncompensated thermal imaging in 15 frames per second with 150 reference frames under 50% HIFU duty ratio.
引用
收藏
页码:2669 / 2678
页数:10
相关论文
共 50 条
  • [21] RESPIRATORY MOTION COMPENSATION FOR IMAGE-GUIDED BRONCHOSCOPY USING A GENERAL MOTION MODEL
    Klinder, Tobias
    Lorenz, Cristian
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 960 - 963
  • [22] Study of satellite imaging with pitch motion compensation to increase SNR
    Xu, Tingting
    Yang, Xiubin
    Xu, Chao
    Chang, Lin
    Zhu, Lin
    OPTIK, 2019, 192
  • [23] Improvement of Medical Ultrasound Strain Image Using Lateral Motion Compensation
    Park, Myung-Ki
    Kwon, Sung-Jae
    Jeong, Mok-Kun
    JOURNAL OF THE ACOUSTICAL SOCIETY OF KOREA, 2011, 30 (05): : 239 - 248
  • [24] Harmonic Motion Imaging for Abdominal Tumor Detection and High-Intensity Focused Ultrasound Ablation Monitoring: An In Vivo Feasibility Study in a Transgenic Mouse Model of Pancreatic Cancer
    Chen, Hong
    Hou, Gary Y.
    Han, Yang
    Payen, Thomas
    Palermo, Carmine F.
    Olive, Kenneth P.
    Konofagou, Elisa E.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2015, 62 (09) : 1662 - 1673
  • [25] Abdominal parametric perfusion imaging with respiratory motion-compensation based on contrast-enhanced ultrasound: In-vivo validation
    Wang, Diya
    Xiao, Mengnan
    Zhang, Yu
    Wan, Mingxi
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2018, 65 : 11 - 21
  • [26] AUTOMATED CATHETER MOTION COMPENSATION IMPROVES 2-D INTRACORONARY ULTRASOUND IMAGING
    HERRINGTON, DM
    VANHORN, M
    ZHU, Y
    YOUNG, T
    SNYDER, WE
    BRADEN, GA
    CIRCULATION, 1994, 90 (04) : 163 - 163
  • [27] MR acoustic radiation force imaging: In vivo comparison to ultrasound motion tracking
    Huang, Yuexi
    Curiel, Laura
    Kukic, Aleksandra
    Plewes, Donald B.
    Chopra, Rajiv
    Hynynen, Kullervo
    MEDICAL PHYSICS, 2009, 36 (06) : 2016 - 2020
  • [28] Motion compensation for the estimation of high-resolution blood flow in ultrafast ultrasound imaging
    Pustovalov, V
    Pham, D. H.
    Remenieras, J. P.
    Kouame, D.
    MEDICAL IMAGING 2022: ULTRASONIC IMAGING AND TOMOGRAPHY, 2022, 12038
  • [29] HIGH FREQUENCY MECHANICAL SCANNING ULTRASOUND IMAGING SYSTEM WITH HIGH PRECISION MOTION COMPENSATION
    Xie, Xu
    Wang, Ninghao
    Han, Zhile
    Gu, Lei
    Jian, Xiaohua
    2022 16TH SYMPOSIUM ON PIEZOELECTRICITY, ACOUSTIC WAVES, AND DEVICE APPLICATIONS, SPAWDA, 2022, : 629 - 632
  • [30] In vivo imaging of vascular pathology in mouse orthotopic glioma model using functional ultrasound
    Rytkonen, Jussi
    Lehtimaki, Kimmo
    Stenius, Taina-Kaisa
    Immonen, Riikka
    Suhonen, Ari
    Shatillo, Artem
    CANCER RESEARCH, 2023, 83 (08)