Diagnostic accuracy of ultrasonography for detecting nasogastric tube (NGT) placement in adults: A systematic review and meta analysis

被引:21
|
作者
Tian, Lin [1 ]
Wendy, Gifford [2 ]
Lan Yutao [1 ]
Qin Xiuqun [3 ]
Liu Xuelian [3 ]
Wang Juan [1 ]
Yang Biping [1 ]
You Tianhui [1 ]
Chen Ken [1 ]
机构
[1] Guangdong Pharmaceut Univ, Sch Nursing, 283 Jianghai Ave, Guangzhou, Guangdong, Peoples R China
[2] Univ Ottawa, Fac Hlth Sci, Sch Nursing, Ottawa, ON, Canada
[3] Sun Yat Sen Univ, Affiliated Hosp 3, Nursing Dept, 600 Tianhe Rd, Guangzhou, Guangdong, Peoples R China
关键词
Nasogastric tube; Ultrasonography; Adult; Systematic review; GASTRIC TUBE; POSITION; CONFIRM; ULTRASOUND;
D O I
10.1016/j.ijnurstu.2017.03.005
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Objective: To review the evidence on diagnostic accuracy of ultrasonography for detecting correct nasogastric tube (NGT) placement in adults compared to X-ray as the reference standard. Methods: This is a systematic review and meta-analysis of observational studies, searched in the literature between 1961 and 2015. We included studies which compared the diagnostic accuracy of ultrasonography detection for NGT placement with X-ray in adult patients who were undergoing NGT placement for any reason in any care setting. We searched published studies in the following electronic databases: Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, CINAHL, Web of Science, WanFang Data, China Journal Net, and the Chinese Biomedical Literature Database. Both English and non-English-language articles were retrieved. Risk of bias was assessed using a standard procedure according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria. Results: We included five studies involving a total of 420 adult patients undergoing nasogastric tube placement: three trials were undertaken in mechanically ventilated patients in prehospital settings and two involved participants with comma or severe trauma in emergency room or intensive care unit (ICU). Pooled results showed that ultrasonography had a sensitivity of 0.93 (95% CI 0.87 to 0.97), and specificity of 0.97 (95% CI 0. 23 to 1.00), suggesting that diagnostic performance of ultrasound is useful to confirm correct NGT placement, but not optimal to detect incorrect NGT position. This was confirmed through a summary receiver operator characteristics (SROC) curve that showed the area under the curve was 0.96 (95% CI 0.94 to 0.98). Discussion: The main limitation of the review is the relatively moderate level of heterogeneity of included studies which may partially undermine the reliability and reproducibility of results. The insufficient studies included did not allow identification of possible sources of heterogeneity and exploration of reporting bias. Due to heterogeneity of studies, the diagnostic performance of ultrasonography could only be drawn cautiously. Physicians and nurses should perform routine X-ray if visualization of NGT is not possible. More well designed studies exploring ultrasound as a diagnostic tool for accuracy of NGT placement are needed to strengthen the current evidence. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:80 / 88
页数:9
相关论文
共 50 条
  • [41] Diagnostic accuracy of preoperative ultrasonography in predicting contralateral inguinal hernia in children: a systematic review and meta-analysis
    Dreuning, K. M. A.
    ten Broeke, C. E. M.
    Twisk, J. W. R.
    Robben, S. G. F.
    van Rijn, R. R.
    Verbeke, J. I. M. L.
    van Heurn, L. W. E.
    Derikx, J. P. M.
    EUROPEAN RADIOLOGY, 2019, 29 (02) : 866 - 876
  • [42] Diagnostic accuracy of ultrasonography in the detection of postsurgical recurrence in Crohn's disease: A systematic review with meta-analysis
    Imperatore, N.
    Rispo, A.
    Testa, A.
    Nardone, O. M.
    Caporaso, N.
    Castiglione, F.
    JOURNAL OF CROHNS & COLITIS, 2018, 12 : S212 - S212
  • [43] DIAGNOSTIC ACCURACY OF ULTRASONOGRAPHY IN THE DETECTION OF POSTSURGICAL RECURRENCE IN CROHN'S DISEASE: A SYSTEMATIC REVIEW WITH META-ANALYSIS
    Imperatore, N.
    Rispo, A.
    Testa, A.
    Nardone, O. M.
    Opramolla, A.
    Caporaso, N.
    Castiglione, F.
    DIGESTIVE AND LIVER DISEASE, 2018, 50 (02) : E137 - E138
  • [44] Diagnostic Accuracy of Ultrasonography in the Detection of Postsurgical Recurrence in Crohn's Disease: A Systematic Review with Meta-analysis
    Rispo, Antonio
    Imperatore, Nicola
    Testa, Anna
    Nardone, Olga Maria
    Luglio, Gaetano
    Caporaso, Nicola
    Castiglione, Fabiana
    INFLAMMATORY BOWEL DISEASES, 2018, 24 (05) : 977 - 988
  • [45] ULTRASONOGRAPHY IN THE DETECTION OF POSTSURGICAL RECURRENCE OF CROHN'S DISEASE: A SYSTEMATIC REVIEW AND META-ANALYSIS OF DIAGNOSTIC ACCURACY
    Khan, Shahab R.
    Deliwala, Smit S.
    Chandan, Saurabh
    Asokkumar, Ravishankar
    Navaneethan, Udayakumar
    Kochhar, Gursimran S.
    Mohan, Babu P.
    GASTROENTEROLOGY, 2023, 164 (06) : S900 - S901
  • [46] Diagnostic Accuracy of Ultrasonography Method of Graf in the Detection of Developmental Dysplasia of the Hip: A Meta-Analysis and Systematic Review
    Chavoshi, Mohammadreza
    Mirshahvalad, Seyed Ali
    Mahdizadeh, Mehrzad
    Zamani, Fatemeh
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2021, 9 (03): : 297 - 305
  • [47] Diagnostic accuracy of palpation and ultrasonography for diagnosing infantile hypertrophic pyloric stenosis: a systematic review and meta- analysis
    Van Den Bunder, Fenne Aim
    Derikx, Joep Pm
    Kiblawi, Rick
    Van Rijn, Rick R.
    Dingemann, Jens
    BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1139):
  • [48] Effectiveness of Positioning in Unconscious Adults During Nasogastric Intubation on Correct Placement and Intubation Time A Systematic Review and Meta-analysis
    Chen, Chen-Ju
    Hung, David Shang Yu
    Wu, Ming-Hsuan
    Lee, Huan-Fang
    Chen, Nai-Ching
    Yang, Hui-Ching
    Hung, Yu-Hsin
    GASTROENTEROLOGY NURSING, 2022, 45 (06) : 395 - 406
  • [49] Complications Associated With Nasogastric Tube Placement in the Acute Phase of Stroke: A Systematic Review
    Nascimento, Ana
    Carvalho, Mariana
    Nogueira, Jerina
    Abreu, Pedro
    Nzwalo, Hipolito
    JOURNAL OF NEUROSCIENCE NURSING, 2018, 50 (04) : 193 - 198
  • [50] Ultrasonography for the Confirmation of Endotracheal Tube Intubation: A Systematic Review and Meta-Analysis
    Gottlieb, Michael
    Holladay, Dallas
    Peksa, Gary D.
    ANNALS OF EMERGENCY MEDICINE, 2018, 72 (06) : 627 - 636