Diagnostic accuracy of ultrasonography for detecting nasogastric tube (NGT) placement in adults: A systematic review and meta analysis

被引:21
|
作者
Tian, Lin [1 ]
Wendy, Gifford [2 ]
Lan Yutao [1 ]
Qin Xiuqun [3 ]
Liu Xuelian [3 ]
Wang Juan [1 ]
Yang Biping [1 ]
You Tianhui [1 ]
Chen Ken [1 ]
机构
[1] Guangdong Pharmaceut Univ, Sch Nursing, 283 Jianghai Ave, Guangzhou, Guangdong, Peoples R China
[2] Univ Ottawa, Fac Hlth Sci, Sch Nursing, Ottawa, ON, Canada
[3] Sun Yat Sen Univ, Affiliated Hosp 3, Nursing Dept, 600 Tianhe Rd, Guangzhou, Guangdong, Peoples R China
关键词
Nasogastric tube; Ultrasonography; Adult; Systematic review; GASTRIC TUBE; POSITION; CONFIRM; ULTRASOUND;
D O I
10.1016/j.ijnurstu.2017.03.005
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Objective: To review the evidence on diagnostic accuracy of ultrasonography for detecting correct nasogastric tube (NGT) placement in adults compared to X-ray as the reference standard. Methods: This is a systematic review and meta-analysis of observational studies, searched in the literature between 1961 and 2015. We included studies which compared the diagnostic accuracy of ultrasonography detection for NGT placement with X-ray in adult patients who were undergoing NGT placement for any reason in any care setting. We searched published studies in the following electronic databases: Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, CINAHL, Web of Science, WanFang Data, China Journal Net, and the Chinese Biomedical Literature Database. Both English and non-English-language articles were retrieved. Risk of bias was assessed using a standard procedure according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria. Results: We included five studies involving a total of 420 adult patients undergoing nasogastric tube placement: three trials were undertaken in mechanically ventilated patients in prehospital settings and two involved participants with comma or severe trauma in emergency room or intensive care unit (ICU). Pooled results showed that ultrasonography had a sensitivity of 0.93 (95% CI 0.87 to 0.97), and specificity of 0.97 (95% CI 0. 23 to 1.00), suggesting that diagnostic performance of ultrasound is useful to confirm correct NGT placement, but not optimal to detect incorrect NGT position. This was confirmed through a summary receiver operator characteristics (SROC) curve that showed the area under the curve was 0.96 (95% CI 0.94 to 0.98). Discussion: The main limitation of the review is the relatively moderate level of heterogeneity of included studies which may partially undermine the reliability and reproducibility of results. The insufficient studies included did not allow identification of possible sources of heterogeneity and exploration of reporting bias. Due to heterogeneity of studies, the diagnostic performance of ultrasonography could only be drawn cautiously. Physicians and nurses should perform routine X-ray if visualization of NGT is not possible. More well designed studies exploring ultrasound as a diagnostic tool for accuracy of NGT placement are needed to strengthen the current evidence. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:80 / 88
页数:9
相关论文
共 50 条
  • [31] Comparison of diagnostic accuracy of Midkine and AFP for detecting hepatocellular carcinoma: a systematic review and meta-analysis
    Lu, Qingqing
    Li, Jie
    Cao, Hui
    Lv, Chenlu
    Wang, Xiaolin
    Cao, Shiqiong
    BIOSCIENCE REPORTS, 2020, 40
  • [32] Diagnostic Accuracy of IDX-DR for Detecting Diabetic Retinopathy: A Systematic Review and Meta-Analysis
    Khan, Zaid
    Gaidhane, Abhay m
    Singh, Mahendra
    Ganesan, Subbulakshmi
    Kaur, Mandeep
    Sharma, Girish chandra
    Rani, Pooja
    Sharma, Rsk
    Thapliyal, Shailendra
    Kushwaha, Monam
    Kumar, Harish
    Agarwal, Rajat kumar
    Shabil, Muhammed
    Verma, Lokesh
    Sidhu, Amritpal
    Manan, Norhafizah binti ab
    Bushi, Ganesh
    Mehta, Rachana
    Sah, Sanjit
    Satapathy, Prakasini
    Samal, Shailesh kumar
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2025, 273 : 192 - 204
  • [33] Diagnostic accuracy of superb microvascular imaging for detecting intraplaque neovascularization: a systematic review and meta-analysis
    Zhao, Lina
    Han, Yubo
    Che, Yanling
    Zhang, Xuesong
    Luo, Min
    Li, Jinzhu
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2023, 13 (05) : 893 - 905
  • [34] Chest CT for detecting COVID-19: a systematic review and meta-analysis of diagnostic accuracy
    Buyun Xu
    Yangbo Xing
    Jiahao Peng
    Zhaohai Zheng
    Weiliang Tang
    Yong Sun
    Chao Xu
    Fang Peng
    European Radiology, 2020, 30 : 5720 - 5727
  • [35] Diagnostic Accuracy of Monofilament Tests for Detecting Diabetic Peripheral Neuropathy: A Systematic Review and Meta-Analysis
    Wang, Fengyi
    Zhang, Jiaqi
    Yu, Jiadan
    Liu, Shaxin
    Zhang, Rengang
    Ma, Xichao
    Yang, Yonghong
    Wang, Pu
    JOURNAL OF DIABETES RESEARCH, 2017, 2017
  • [36] Diagnostic accuracy of ultrasound for rotator cuff tears in adults: A systematic review and meta-analysis
    Smith, T. O.
    Back, T.
    Toms, A. P.
    Hing, C. B.
    CLINICAL RADIOLOGY, 2011, 66 (11) : 1036 - 1048
  • [37] Diagnostic accuracy of endometrial sampling tests for detecting endometrial cancer: a systematic review and meta-analysis
    Sakna, Noha Abdelsattar
    Elgendi, Marwa
    Salama, Mohamed Hamed
    Zeinhom, Ahmed
    Labib, Somia
    Nabhan, Ashraf Fawzy
    BMJ OPEN, 2023, 13 (06):
  • [38] Diagnostic accuracy of ultrasound in detecting the severity of abnormally invasive placentation: a systematic review and meta-analysis
    Pagani, Giorgio
    Cali, Giuseppe
    Acharya, Ganesh
    Trisch, Ilan-Timor
    Palacios-Jaraquemada, Jose
    Familiari, Alessandra
    Buca, Danilo
    Manzoli, Lamberto
    Flacco, Maria E.
    Fanfani, Francesco
    Liberati, Marco
    Scambia, Giovanni
    D'Antonio, Francesco
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2018, 97 (01) : 25 - 37
  • [39] Chest CT for detecting COVID-19: a systematic review and meta-analysis of diagnostic accuracy
    Xu, Buyun
    Xing, Yangbo
    Peng, Jiahao
    Zheng, Zhaohai
    Tang, Weiliang
    Sun, Yong
    Xu, Chao
    Peng, Fang
    EUROPEAN RADIOLOGY, 2020, 30 (10) : 5720 - 5727
  • [40] Diagnostic accuracy of preoperative ultrasonography in predicting contralateral inguinal hernia in children: a systematic review and meta-analysis
    K. M. A. Dreuning
    C. E. M. ten Broeke
    J. W. R. Twisk
    S. G. F. Robben
    R. R. van Rijn
    J. I. M. L. Verbeke
    L. W. E. van Heurn
    J. P. M. Derikx
    European Radiology, 2019, 29 : 866 - 876