Diagnostic accuracy of ultrasonography for detecting nasogastric tube (NGT) placement in adults: A systematic review and meta analysis

被引:21
|
作者
Tian, Lin [1 ]
Wendy, Gifford [2 ]
Lan Yutao [1 ]
Qin Xiuqun [3 ]
Liu Xuelian [3 ]
Wang Juan [1 ]
Yang Biping [1 ]
You Tianhui [1 ]
Chen Ken [1 ]
机构
[1] Guangdong Pharmaceut Univ, Sch Nursing, 283 Jianghai Ave, Guangzhou, Guangdong, Peoples R China
[2] Univ Ottawa, Fac Hlth Sci, Sch Nursing, Ottawa, ON, Canada
[3] Sun Yat Sen Univ, Affiliated Hosp 3, Nursing Dept, 600 Tianhe Rd, Guangzhou, Guangdong, Peoples R China
关键词
Nasogastric tube; Ultrasonography; Adult; Systematic review; GASTRIC TUBE; POSITION; CONFIRM; ULTRASOUND;
D O I
10.1016/j.ijnurstu.2017.03.005
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Objective: To review the evidence on diagnostic accuracy of ultrasonography for detecting correct nasogastric tube (NGT) placement in adults compared to X-ray as the reference standard. Methods: This is a systematic review and meta-analysis of observational studies, searched in the literature between 1961 and 2015. We included studies which compared the diagnostic accuracy of ultrasonography detection for NGT placement with X-ray in adult patients who were undergoing NGT placement for any reason in any care setting. We searched published studies in the following electronic databases: Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, CINAHL, Web of Science, WanFang Data, China Journal Net, and the Chinese Biomedical Literature Database. Both English and non-English-language articles were retrieved. Risk of bias was assessed using a standard procedure according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria. Results: We included five studies involving a total of 420 adult patients undergoing nasogastric tube placement: three trials were undertaken in mechanically ventilated patients in prehospital settings and two involved participants with comma or severe trauma in emergency room or intensive care unit (ICU). Pooled results showed that ultrasonography had a sensitivity of 0.93 (95% CI 0.87 to 0.97), and specificity of 0.97 (95% CI 0. 23 to 1.00), suggesting that diagnostic performance of ultrasound is useful to confirm correct NGT placement, but not optimal to detect incorrect NGT position. This was confirmed through a summary receiver operator characteristics (SROC) curve that showed the area under the curve was 0.96 (95% CI 0.94 to 0.98). Discussion: The main limitation of the review is the relatively moderate level of heterogeneity of included studies which may partially undermine the reliability and reproducibility of results. The insufficient studies included did not allow identification of possible sources of heterogeneity and exploration of reporting bias. Due to heterogeneity of studies, the diagnostic performance of ultrasonography could only be drawn cautiously. Physicians and nurses should perform routine X-ray if visualization of NGT is not possible. More well designed studies exploring ultrasound as a diagnostic tool for accuracy of NGT placement are needed to strengthen the current evidence. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:80 / 88
页数:9
相关论文
共 50 条
  • [1] Diagnostic accuracy of ultrasonography for detecting gastric tube placement: an updated meta-analysis
    Peng, J.
    Tang, M.
    Liu, L. -L.
    Chen, W. -T.
    Ye, Q. -H.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2022, 26 (17) : 6328 - 6339
  • [2] Accuracy of biochemical markers for predicting nasogastric tube placement in adults-A systematic review of diagnostic studies
    Fernandez, Ritin S.
    Chau, Janita Pak-Chun
    Thompson, David R.
    Griffiths, Rhonda
    Lo, Hoi-Shan
    INTERNATIONAL JOURNAL OF NURSING STUDIES, 2010, 47 (08) : 1037 - 1046
  • [3] The Auscultation for Predicting Nasogastric Tube Placement in Adults: A Systematic Review
    Tang, Li
    Li, Kang
    PSYCHOLOGY, MANAGEMENT AND SOCIAL SCIENCE, 2013, 18 : 111 - 114
  • [4] Diagnostic accuracy of ultrasonography for the confirmation of endotracheal tube intubation: a systematic review and meta-analysis
    Li, Xuxia
    Zhang, Jiapeng
    Karunakaran, Monica
    Hariharan, Vishnu Shankar
    MEDICAL ULTRASONOGRAPHY, 2023, 25 (01) : 72 - 81
  • [5] Diagnostic accuracy of end-tidal carbon dioxide detection in determining correct placement of nasogastric tube: An updated systematic review with meta-analysis
    Chau, Janita Pak Chun
    Liu, Xu
    Choi, Kai Chow
    Lo, Suzanne Hoi Shan
    Lam, Simon Kwun Yu
    Chan, Kam Ming
    Zhao, Jie
    Thompson, David R.
    INTERNATIONAL JOURNAL OF NURSING STUDIES, 2021, 123
  • [6] Ultrasonography for confirmation of endotracheal tube placement: A systematic review and meta-analysis
    Chou, Eric H.
    Dickman, Eitan
    Tsou, Po-Yang
    Tessaro, Mark
    Tsai, Yang-Ming
    Ma, Matthew Huei-Ming
    Lee, Chien-Chang
    Marshall, John
    RESUSCITATION, 2015, 90 : 97 - 103
  • [7] Psychological Effects of Nasogastric Tube (NGT) in Patients with Anorexia Nervosa: A Systematic Review
    Amianto, Federico
    Oliaro, Tomaso
    Righettoni, Francesca
    Davico, Chiara
    Marcotulli, Daniele
    Vitiello, Benedetto
    NUTRIENTS, 2024, 16 (14)
  • [8] Diagnostic Accuracy of Ultrasonography for Rotator Cuff Tears: A Systematic Review and Meta-analysis
    Farooqi, Ali S.
    Lee, Alexander
    Novikov, David
    Kelly, Ann Marie
    Li, Xinning
    Kelly, John D.
    Parisien, Robert L.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (10)
  • [9] Diagnostic Accuracy of Ultrasonography for Detection of Intussusception in Children; a Systematic Review and Meta-Analysis
    Rahmani, Erfan
    Amani-Beni, Reza
    Hekmatnia, Yasaman
    Yaseri, Amirhossein Fakhre
    Ahadiat, Seyed Amirabbas
    Boroujeni, Parham Talebi
    Kiani, Moein
    Tavakoli, Reza
    Shafagh, Seyyed-Ghavam
    Shirazinia, Matin
    Garousi, Setareh
    Mottahedi, Mehran
    Arzaghi, Mohammadreza
    Benam, Sasan Pourbagher
    Rigi, Amir
    Salmani, Amir
    Abdollahi, Zeynab
    Rokni, Fateme Karimzade
    Nikbakht, Tara
    Abadi, Saeme Azizi Hassan
    Roohinezhad, Roozbeh
    Masheghati, Forough
    Haririan, Yas
    Darouei, Bahar
    Fayyazishishavan, Ehsan
    Manoochehri-Arash, Niusha
    Farrokhi, Mehrdad
    ARCHIVES OF ACADEMIC EMERGENCY MEDICINE, 2023, 11 (01)
  • [10] Systematic review and meta-analysis of the diagnostic accuracy of ultrasonography for deep vein thrombosis
    Goodacre S.
    Sampson F.
    Thomas S.
    van Beek E.
    Sutton A.
    BMC Medical Imaging, 5 (1)