Prosthesis-patient mismatch affects survival after aortic valve replacement

被引:1
|
作者
Rao, V
Jamieson, WRE
Ivanov, J
Armstrong, S
David, TE
机构
[1] Toronto Gen Hosp, Div Cardiovasc Surg, Toronto, ON M5G 2C4, Canada
[2] Vancouver Gen Hosp, Div Cardiovasc Surg, Toronto, ON M5G 2C4, Canada
关键词
aorta; valves; survival;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Surgeons traditionally avoid the use of "small" aortic prostheses because of the potential for residual left ventricular outflow tract obstruction and persistent transvalvular gradients. This study examines the ratio between prosthetic valve size and the body surface area (BSA) of patients undergoing aortic valve replacement (AVR). We sought to determine the effect of potential "prosthesis-patient" mismatch on long-term survival. Methods and Results-Follow-up was conducted on 2981 patients who underwent AVR with stented bioprostheses between 1976 and 1996. To account for differences between manufacturers' labeled valve sizes, we calculated the ratio between the prosthetic valve effective orifice area (EOA) and the patient's BSA (recorded for 2154 patients). The lowest decile in this cohort had a calculated EOA/BSA of <0.75 cm(2)/m(2) (Small group, n=227) compared with the control group (n=1927), in whom the EOA/BSA ratio was >0.75 cm(2)/m(2). Operative mortality was higher in the Small group (8% versus 5%, P=0.03), Actuarial survival at 12 years was 50+/-5% in the Small group compared with 49+/-2% in the control group (P=0.27). However, freedom from valve-related mortality was significantly lower in the Small group (75+/-5% versus 84+/-2%, P=0.004). Cox regression analysis determined age and NYHA functional class to be the multivariate predictors of overall mortality, whereas advanced age and EOA/BSA <0.75 cm(2)/m(2) were found to be the predictors of valve-related mortality. Conclusions-Prosthesis-patient mismatch results in significantly higher early and late mortality after bioprosthetic AVR. We recommend careful selection of stented bioprostheses to ensure an adequate ratio of EOA to BSA. An EOA/BSA ratio of >0.75 cm(2)/m(2) may avoid residual left ventricular outflow tract obstruction and persistent transvalvular gradients. Careful prosthesis-patient matching will improve both early and late survival after AVR.
引用
收藏
页码:5 / 9
页数:5
相关论文
共 50 条
  • [11] Prosthesis-Patient Mismatch After Aortic Valve Replacement: Is It Time for a Redefinition?
    Mannacio, Vito
    De Amicis, Vincenzo
    Vosa, Carlo
    ANNALS OF THORACIC SURGERY, 2014, 97 (04): : 1482 - 1482
  • [12] Prosthesis-patient mismatch affects long-term survival after mechanical valve replacement
    Kohsaka, Shun
    Mohan, Shaulnie
    Virani, Salim
    Lee, Vei-Vei
    Contreras, Ariadna
    Reul, George J.
    Coulter, Stephanie A.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 135 (05): : 1076 - 1080
  • [13] Prosthesis-patient mismatch affects late survival after valve surgery for severe aortic stenosis
    Swinkels, Ben M.
    Ten Berg, Jurrien M.
    Kelder, Johannes C.
    Vermeulen, Freddy E.
    van Boven, Wim J.
    de Mol, Bas A.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2022, 63 (01): : 91 - 98
  • [14] Impact of prosthesis-patient mismatch on survival after mitral valve replacement
    Magne, J.
    Mathieu, P.
    Dumesnil, J. G.
    Tanne, D.
    Dagenais, F.
    Doyle, D.
    Pibarot, P.
    EUROPEAN HEART JOURNAL, 2006, 27 : 833 - 833
  • [15] Impact of prosthesis-patient mismatch on survival after mitral valve replacement
    Magne, Julien
    Mathieu, Patrick
    Dumesnil, Jean G.
    Tanne, David
    Dagenais, Francois
    Doyle, Daniel
    Pibarot, Philippe
    CIRCULATION, 2007, 115 (11) : 1417 - 1425
  • [16] Prosthesis-Patient Mismatch After Aortic Valve Replacement: Effect on Long-Term Survival
    Swinkels, Ben M.
    de Mol, Bas A.
    Kelder, Johannes C.
    Vermeulen, Freddy E.
    ten Berg, Jurrien M.
    ANNALS OF THORACIC SURGERY, 2016, 101 (04): : 1388 - 1394
  • [17] Impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement
    Mohty, Dania
    Dumesnil, Jean G.
    Echahidi, Najmeddine
    Mathieu, Patrick
    Dagenais, Francois
    Voisine, Pierre
    Pibarot, Philippe
    CIRCULATION, 2007, 116 (16) : 712 - 712
  • [18] Impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement
    Mohty, D.
    Dumesnil, J. G.
    Echahidi, N.
    Mathieu, P.
    Dagenais, F.
    Voisine, P.
    Pibarot, P.
    CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 : 259C - 259C
  • [19] Aortic Prosthesis-Patient Mismatch Strongly Affects Early Results of Double Valve Replacement
    Iosifescu, Andrei George
    Moldovan, Horatiu
    Iliescu, Vlad Anton
    JOURNAL OF HEART VALVE DISEASE, 2014, 23 (02): : 149 - 157
  • [20] Prosthesis-patient mismatch after surgical aortic valve replacement in patients with aortic stenosis
    Kim, Hee Jung
    Kim, Ho Jin
    Kim, Joon Bum
    Jung, Sung-Ho
    Choo, Suk Jung
    Chung, Cheol Hyun
    Lee, Jae Won
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2020, 31 (02) : 152 - 157