Prosthesis-patient mismatch affects late survival after valve surgery for severe aortic stenosis

被引:3
|
作者
Swinkels, Ben M. [1 ]
Ten Berg, Jurrien M. [1 ]
Kelder, Johannes C. [1 ]
Vermeulen, Freddy E. [2 ]
van Boven, Wim J. [3 ]
de Mol, Bas A. [3 ]
机构
[1] St Antonius Hosp, Dept Cardiol, Koekoekslaan 1, NL-3435 CM Nieuwegein, Netherlands
[2] St Antonius Hosp, Dept Cardiothorac Surg, Nieuwegein, Netherlands
[3] Univ Amsterdam, Locat Acad Med Ctr, Dept Cardiothorac Surg, Med Ctr, Amsterdam, Netherlands
来源
JOURNAL OF CARDIOVASCULAR SURGERY | 2022年 / 63卷 / 01期
关键词
Transcatheter aortic valve replacement; Heart valve prosthesis; Heart valve prosthesis implantation; HIGH-RISK PATIENTS; CLINICAL IMPACT; REPLACEMENT; MORTALITY; TRIAL;
D O I
10.23736/S0021-9509.21.11786-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The effect of prosthesis-patient mismatch (PPM) on late survival after aortic valve replacement (AVR) in patient with symptomatic severe aortic stenosis (AS) remains unclear. Also, late follow-up in previous studies is confined to only one decade. We aimed to determine the effect of PPM on late survival after isolated AVR for symptomatic severe AS during 25 years of follow-up. METHODS: In this retrospective cohort study, Kaplan-Meier survival analysis was performed to determine late survival in 404 consecutive patients with moderate PPM (N.=86), severe (N.=11), or no/mild PPM (N.=307) after isolated AVR for symptomatic severe AS during a mean follow-up of 25.0 +/- 2.9 years. Moderate, severe, and no/mild PPM were defined as indexed effective orifice area of >0.65 <= 0.85, <= 0.65, and >0.85 cm(2)/m(2), respectively. Multivariable analysis was performed to identify possible independent predictors of decreased late survival, including moderate or severe PPM. RESULTS: Late survival of patients with severe PPM was worse in comparison with those with no/mild PPM: 7.4 +/- 2.6 (95% confidence interval 2.2-12.5) vs. 13.6 +/- 0.5 (95% confidence interval 12.6-14.6) years, respectively; P=0.020. Late survival of patients with moderate PPM was similar to those with no/mild PPM. Severe PPM was an independent predictor of decreased late survival: hazards ratio 4.002 (95% confidence interval 1.869-8.569); P<0.001. Moderate PPM was not an independent predictor of decreased late survival. CONCLUSIONS: Severe PPM was independently associated with decreased late survival after isolated AVR for symptomatic severe AS during a mean follow-up of 25.0 +/- 2.9 years. Therefore, severe PPM should be prevented as much as possible.
引用
收藏
页码:91 / 98
页数:8
相关论文
共 50 条
  • [1] Prosthesis-patient mismatch affects survival after aortic valve replacement
    Rao, V
    Jamieson, WRE
    Ivanov, J
    Armstrong, S
    David, TE
    CIRCULATION, 2000, 102 (19) : 5 - 9
  • [2] Prosthesis-patient Mismatch Affects Long-term Survival After Aortic Valve Replacement
    Ennker, Juergen
    Albert, Alexander
    Boening, Andreas
    Ennker, Ina C.
    Florath, Ines
    CIRCULATION, 2010, 122 (21)
  • [3] Prosthesis-patient mismatch after surgical aortic valve replacement in patients with aortic stenosis
    Kim, Hee Jung
    Kim, Ho Jin
    Kim, Joon Bum
    Jung, Sung-Ho
    Choo, Suk Jung
    Chung, Cheol Hyun
    Lee, Jae Won
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2020, 31 (02) : 152 - 157
  • [4] Clinical predictors of prosthesis-patient mismatch after aortic valve replacement for aortic stenosis
    Astudillo, Luis M.
    Santana, Orlando
    Urbandt, Pablo A.
    Benjo, Alexandre M.
    Elkayam, Lior U.
    Nascimento, Francisco O.
    Lamas, Gervasio A.
    Lamelas, Joseph
    CLINICS, 2012, 67 (01) : 55 - 60
  • [5] Prosthesis-patient mismatch after aortic valve replacement
    Dahou A.
    Mahjoub H.
    Pibarot P.
    Current Treatment Options in Cardiovascular Medicine, 2016, 18 (11)
  • [6] Prosthesis-patient mismatch in aortic stenosis
    Honda K.
    Okamura Y.
    General Thoracic and Cardiovascular Surgery, 2014, 62 (2) : 78 - 86
  • [7] Prosthesis-patient mismatch affects long-term survival after mechanical aortic valve replacement
    Mohan, S
    Kohsaka, S
    Contreras, A
    Lee, VV
    Reul, RM
    Reul, GJ
    Coulter, SA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 282A - 282A
  • [8] Effect of prosthesis-patient mismatch on survival after aortic valve replacement using mechanical prostheses in patients with aortic stenosis
    Tsutsumi K.
    Nagumo M.
    Nishikawa K.
    Takahashi R.
    General Thoracic and Cardiovascular Surgery, 2008, 56 (12) : 577 - 583
  • [9] Prosthesis-patient mismatch after aortic valve replacement: Impact of age and body size on late survival
    Moon, MR
    Pasque, MK
    Munfakh, NA
    Melby, SJ
    Lawton, JS
    Moazami, N
    Codd, JE
    Crabtree, TD
    Barner, HB
    Damiano, RJ
    ANNALS OF THORACIC SURGERY, 2006, 81 (02): : 481 - 489
  • [10] Aortic valve replacement for aortic stenosis in the elderly: Influence of prosthesis-patient mismatch on late survival and left ventricular mass regression
    Kato Y.
    Tsutsumi Y.
    Kawai T.
    Goto T.
    Takahashi Y.
    Ohashi H.
    General Thoracic and Cardiovascular Surgery, 2008, 56 (8) : 397 - 403