Prosthesis-patient mismatch affects late survival after valve surgery for severe aortic stenosis

被引:3
|
作者
Swinkels, Ben M. [1 ]
Ten Berg, Jurrien M. [1 ]
Kelder, Johannes C. [1 ]
Vermeulen, Freddy E. [2 ]
van Boven, Wim J. [3 ]
de Mol, Bas A. [3 ]
机构
[1] St Antonius Hosp, Dept Cardiol, Koekoekslaan 1, NL-3435 CM Nieuwegein, Netherlands
[2] St Antonius Hosp, Dept Cardiothorac Surg, Nieuwegein, Netherlands
[3] Univ Amsterdam, Locat Acad Med Ctr, Dept Cardiothorac Surg, Med Ctr, Amsterdam, Netherlands
来源
JOURNAL OF CARDIOVASCULAR SURGERY | 2022年 / 63卷 / 01期
关键词
Transcatheter aortic valve replacement; Heart valve prosthesis; Heart valve prosthesis implantation; HIGH-RISK PATIENTS; CLINICAL IMPACT; REPLACEMENT; MORTALITY; TRIAL;
D O I
10.23736/S0021-9509.21.11786-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The effect of prosthesis-patient mismatch (PPM) on late survival after aortic valve replacement (AVR) in patient with symptomatic severe aortic stenosis (AS) remains unclear. Also, late follow-up in previous studies is confined to only one decade. We aimed to determine the effect of PPM on late survival after isolated AVR for symptomatic severe AS during 25 years of follow-up. METHODS: In this retrospective cohort study, Kaplan-Meier survival analysis was performed to determine late survival in 404 consecutive patients with moderate PPM (N.=86), severe (N.=11), or no/mild PPM (N.=307) after isolated AVR for symptomatic severe AS during a mean follow-up of 25.0 +/- 2.9 years. Moderate, severe, and no/mild PPM were defined as indexed effective orifice area of >0.65 <= 0.85, <= 0.65, and >0.85 cm(2)/m(2), respectively. Multivariable analysis was performed to identify possible independent predictors of decreased late survival, including moderate or severe PPM. RESULTS: Late survival of patients with severe PPM was worse in comparison with those with no/mild PPM: 7.4 +/- 2.6 (95% confidence interval 2.2-12.5) vs. 13.6 +/- 0.5 (95% confidence interval 12.6-14.6) years, respectively; P=0.020. Late survival of patients with moderate PPM was similar to those with no/mild PPM. Severe PPM was an independent predictor of decreased late survival: hazards ratio 4.002 (95% confidence interval 1.869-8.569); P<0.001. Moderate PPM was not an independent predictor of decreased late survival. CONCLUSIONS: Severe PPM was independently associated with decreased late survival after isolated AVR for symptomatic severe AS during a mean follow-up of 25.0 +/- 2.9 years. Therefore, severe PPM should be prevented as much as possible.
引用
收藏
页码:91 / 98
页数:8
相关论文
共 50 条
  • [41] Severe prosthesis-patient mismatch after aortic valve replacement for aortic stenosis: Analysis of risk factors for early and long-term mortality
    Mannacio, Vito
    Mannacio, Luigi
    Mango, Emilo
    Antignano, Anita
    Mottola, Michele
    Caparrotti, Sergio
    Musumeci, Francesco
    Vosa, Carlo
    JOURNAL OF CARDIOLOGY, 2017, 69 (1-2) : 333 - 339
  • [42] Aortic Prosthesis-Patient Mismatch Strongly Affects Early Results of Double Valve Replacement
    Iosifescu, Andrei George
    Moldovan, Horatiu
    Iliescu, Vlad Anton
    JOURNAL OF HEART VALVE DISEASE, 2014, 23 (02): : 149 - 157
  • [43] Long-Term Outcome After Aortic Valve Replacement of Patients With Prosthesis-Patient Mismatch and Paradoxical Low Flow, Severe Aortic Stenosis
    Boulogne, Cyrille
    Mohty, Dania
    Magne, Julien
    Aboyans, Victor
    Pibarot, Philippe
    Echahidi, Najmeddine
    Cornu, Elisabeth
    Laskar, Marc
    Virot, Patrice
    CIRCULATION, 2013, 128 (22)
  • [44] A meta-analysis of effects of prosthesis-patient mismatch after aortic valve replacement on late mortality
    Takagi, Hisato
    Yamamoto, Hirotaka
    Iwata, Kotaro
    Goto, Shin-nosuke
    Umemoto, Takuya
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 159 (02) : 150 - 154
  • [45] Prosthesis-Patient Mismatch After "High-Risk" Aortic Valve Replacement
    Popma, Jeffrey J.
    Khabbaz, Kamal
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (13) : 1335 - 1338
  • [46] The Incidence and Consequence of Prosthesis-Patient Mismatch After Surgical Aortic Valve Replacement
    Fallon, John M.
    DeSimone, Joseph P.
    Brennan, J. Matthew
    O'Brien, Sean
    Thibault, Dylan P.
    DiScipio, Anthony W.
    Pibarot, Philippe
    Jacobs, Jeffrey P.
    Malenka, David J.
    Clarizia, Nadia A.
    Ruel, Marc
    ANNALS OF THORACIC SURGERY, 2018, 106 (01): : 14 - 23
  • [47] Imaging for Predicting and Assessing Prosthesis-Patient Mismatch After Aortic Valve Replacement
    Pibarot, Philippe
    Magne, Julien
    Leipsic, Jonathon
    Cote, Nancy
    Blanke, Philippe
    Thourani, Vinod H.
    Hahn, Rebecca
    JACC-CARDIOVASCULAR IMAGING, 2019, 12 (01) : 149 - 162
  • [48] Prosthesis-Patient Mismatch after Aortic Valve Replacement with the Mosaic Ultra Bioprosthesis
    Ntinopoulos, Vasileios
    Biefer, Hector Rodriguez Cetina
    Dushaj, Stak
    Rings, Laura
    Fleckenstein, Philine
    Dzemali, Omer
    Haeussler, Achim
    THORACIC AND CARDIOVASCULAR SURGEON, 2024, 72 (03): : 197 - 204
  • [49] Incidence and Impact of Prosthesis-Patient Mismatch after Transcatheter Aortic Valve Implantation
    Bleiziffer, Sabine
    Hettich, Ina
    Hutter, Andrea
    Wagner, Anke
    Deutsch, Marcus-Andre
    Piazza, Nicolo
    Lange, Ruediger
    JOURNAL OF HEART VALVE DISEASE, 2013, 22 (03): : 309 - 316
  • [50] Impact of prosthesis-patient mismatch on mitral regurgitation after aortic valve replacement
    Unger, P.
    Magne, J.
    Eynden, F. Vanden
    Plein, D.
    Van Camp, G.
    Pasquet, A.
    Cosyns, B.
    Dedobbeleer, C.
    Lancellotti, P.
    HEART, 2010, 96 (20) : 1627 - 1632