Beamline optimization for 100keV diagnostic neutral beam (DNB) injector for ITER

被引:0
|
作者
Bandyopadhyay, M. [1 ]
Singh, M. J. [1 ]
Rotti, C. [1 ]
Chakraborty, A. [1 ]
Hemsworth, R. [2 ]
Schunke, B. [2 ]
机构
[1] Inst Plasma Res, ITER India, Gandhinagar 382428, Gujarat, India
[2] ITER IO, F-13108 St Paul Les Durance, France
关键词
ITER; neutral beam; beamline components; diagnostic; beam transmission;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The 100 kV negative hydrogen ion source based Diagnostic Neutral Beam (DNB) injector, which forms a part of the IN Procurement Package for ITER, targets a delivery of similar to 18-20A of neutral hydrogen atom beam current into the ITER torus for charge exchange resonance spectroscopy (CXRS) diagnostics. Considering stripping losses, similar to 70A negative ion current is required to be extracted from the ion source, which leads to a production of 60 A of accelerated ion beam. Subsequent process of neutralization, electrostatic ion separation and transport to the duct leads to a large separation between the points of generation of ion beam to the point of delivery of the neutral beam into the Torus (similar to 23 m). This forms one of the most important constraints for the transport of neutral beams to ITER. The requirements are not only for a stringent control over ion optics, the transport to electrostatic separator, minimum loss of beam due to intercepting elements, low reionization loss, focusing to control interception losses, adequate compensation of residual magnetic fields to overcome magnetic field induced deflections also forms important design issues for a reasonable transmission efficiency. Due to the multi parameter dependence, it becomes necessary to assess different scenarios using numerical codes. In the present case the assessment has been carried out for the DNB using the beam transport codes PDP, BTR and the MCGF codes which are developed by the Russian Federation. An optimized configuration of the beam line has been arrived at on the basis of these codes enabled studies. These parameters are: listing of the vertical and horizontal focal lengths as 20.6 m, a spacing between ground grid and neutralizer of 1 m, positioning of RID at a distance of 0.75 m from the neutraliser exit. Further, optimizing the gas feed to the source and neutralizer lead to a final transmission of similar to 35% of the extracted beam power to the torus. The paper shall present the methodology, the issues concerned and the final configuration which forms the basis for the present engineering.
引用
收藏
页码:150 / +
页数:2
相关论文
共 50 条
  • [31] Diagnostic Neutral Beam for ITER - concept to Engineering
    Chakraborty, A.
    Rotti, C.
    Bandyopadhyay, M.
    Singh, M. J.
    Roopesh, G.
    Shah, Sejal
    Baruah, U. K.
    Hemsworth, R.
    Schunke, B.
    2009 23RD IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING, 2009, : 158 - +
  • [32] RAMI Analyses of Heating Neutral Beam and Diagnostic Neutral Beam Systems for ITER
    Chang, D. H.
    Lee, S.
    Hemsworth, R.
    van Houtte, D.
    Okayama, K.
    Sagot, F.
    Schunke, B.
    Svensson, L.
    SECOND INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES, 2011, 1390
  • [33] Vacuum Insulation and Achievement of 980 keV,185 A/m~2 H-Ion Beam Acceleration at JAEA for the ITER Neutral Beam Injector
    Hiroyuki TOBARI
    Masaki TANIGUCHI
    Mieko KASHIWAGI
    Masayuki DAIRAKU
    Naotaka UMEDA
    Haruhiko YAMANAKA
    Kazuki TSUCHIDA
    Jumpei TAKEMOTO
    Kazuhiro WATANABE
    Takashi INOUE
    Keishi SAKAMOTO
    Plasma Science and Technology, 2013, 15 (02) : 179 - 183
  • [34] A suite of diagnostics to validate and optimize the prototype ITER neutral beam injector
    Pasqualotto, R.
    Agostini, M.
    Barbisan, M.
    Brombin, M.
    Cavazzana, R.
    Croci, G.
    Dalla Palma, M.
    Delogu, R. S.
    De Muri, M.
    Muraro, A.
    Peruzzo, S.
    Pimazzoni, A.
    Pomaro, N.
    Rebai, M.
    Rizzolo, A.
    Sartori, E.
    Serianni, G.
    Spagnolo, S.
    Spolaore, M.
    Tardocchi, M.
    Zaniol, B.
    Zaupa, M.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [35] HV Holding in Vacuum, a Key Issue for the ITER Neutral Beam Injector
    De Lorenzi, Antonio
    Kashiwagi, Mieko
    De Esch, Hubert P. L.
    Pilan, Nicola
    Kojima, Atsushi
    Svensson, Lennart
    Chitarin, Giuseppe
    Umeda, Naotaka
    Tobari, Hiroyuki
    PROCEEDINGS OF THE 2018 28TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2018), VOL 2, 2018, : 721 - 729
  • [36] Multicusp trap as model of plasma neutralizer for ITER neutral beam injector
    Belyaev, VA
    Dubrovin, MM
    Kosarev, PM
    Skovoroda, AA
    Spitsyn, AV
    Terent'ev, AA
    Yanchenkov, SV
    Zhil'tsov, VA
    Zubarev, VF
    FUSION SCIENCE AND TECHNOLOGY, 2005, 47 (1T) : 124 - 127
  • [37] Electroquasistatic Analysis of the Gas Insulated Line for the ITER Neutral Beam Injector
    Bettini, P.
    Specogna, R.
    Trevisan, F.
    IEEE TRANSACTIONS ON MAGNETICS, 2009, 45 (03) : 996 - 999
  • [38] The timing system of the ITER full size neutral beam injector prototype
    Manduchi, G.
    Luchetta, A.
    Taliercio, C.
    Rigoni, A.
    FUSION ENGINEERING AND DESIGN, 2019, 146 : 281 - 284
  • [39] Upgrade of the diagnostic neutral beam injector for the TCV tokamak
    Karpushov, AN
    Abdrashitov, GF
    Averboukh, II
    Bosshard, P
    Condrea, I
    Duval, BP
    Ivanov, AA
    Kolmogorov, VV
    Mlynar, J
    Perez, A
    Shikhovtsev, IV
    Shukaev, AN
    Weisen, H
    FUSION ENGINEERING AND DESIGN, 2003, 66-68 : 899 - 904
  • [40] RF plasma emitter for diagnostic neutral beam injector
    Shikhovtsev, IV
    Abdrashitov, GF
    Davydenko, VI
    Deichuli, PP
    Ivanov, AA
    Mishagin, VV
    Averbukh, II
    Podminogin, AA
    INTERNATIONAL CONFERENCE ON PHENOMENA IN IONIZED GASES, VOL III, PROCEEDINGS, 1999, : 99 - 100