A 110 kV Transformer Fault Simulation and Comprehensive Analysis

被引:0
|
作者
Wei, Jufang [1 ]
He, Chun [1 ]
Feng, Junji [1 ]
Liu, Liqing [1 ]
Zhang, Chunhui [1 ]
Tang, Qinghua [1 ]
Zhang, Xin [2 ]
Zhang, He [1 ]
机构
[1] Tianjin Elect Power Corp, Elect Power Res Inst, Equipment Status Evaluat Ctr, Tianjin, Peoples R China
[2] Tianjin Elect Power Corp, Sci & Technol Management Dept, Tianjin, Peoples R China
关键词
transformer; faults; short circuit; simulation analysis;
D O I
10.1109/IFEEA57288.2022.10038016
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
According to the statistics of transformer faults in recent ten years, transformer short circuit is the primary cause of transformer faults, accounting for more than 30%. In this paper, in view of a heavy gas action event of 110kV main transformer, combined with the protection action, the fault recording diagram is analyzed in detail, and the preliminary conclusion of the fault cause is given through simulation analysis. The results show that the fault is caused by the inter-turn and inter-layer short circuit fault in the transformer. Combined with this fault, the analysis method of transformer fault is proposed, and the relevant technical measures are put forward for this type of transformer fault, so as to further prevent the occurrence of fault and improve the level of safe operation of transformer.
引用
收藏
页码:930 / 935
页数:6
相关论文
共 50 条
  • [31] NOISE-REDUCTION ON A 110-KV FEED TRANSFORMER
    HAUSIGK, D
    STAHL UND EISEN, 1978, 98 (18): : 954 - 955
  • [32] Simulation Study on Internal Fault of Transformer
    Song, Haihui
    Zhao, Fangming
    He, Di
    INTERNATIONAL CONFERENCE ON SOLID STATE DEVICES AND MATERIALS SCIENCE, 2012, 25 : 459 - 464
  • [33] Test and Analysis on Extended Temperature Rise of 110 kV Transformer Based on Distributed Temperature Sensing
    Li, Huan
    Liu, Yunpeng
    Zhuang, Xinyu
    Xiao, Hai
    Fan, Xiaozhou
    Wang, Jiaxue
    Li, Xinye
    Jiang, Taofei
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (02) : 1030 - 1041
  • [34] Analysis Of Low Reactance Grounding Protection In 110KV Main Transformer Neutral System
    Ping Shaoxun
    Zhou Yufang
    Zhang Xuefeng
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 227 - 231
  • [35] Analysis and remedial measures of the unsuccessful causes of the automatic backup power in 110 kV transformer substation
    Lengshuijiang Electric Power Bureau, Lengshuijiang 417500, China
    Dianli Xitong Baohu yu Kongzhi, 2009, 2 (91-92):
  • [36] Protection action analysis of 500 kV converter transformer fault in nanqiao converter station
    Lü, Pengfei
    Liang, Zhifeng
    Ruan, Siye
    Wang, Delin
    Wang, Yuling
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2013, 37 (16): : 125 - 128
  • [37] Two-Terminal Algorithm Analysis for Unsymmetrical Fault Location on 110 kV Lines
    Bukvisova, Zuzana
    Orsagova, Jaroslava
    Topolanek, David
    Toman, Petr
    ENERGIES, 2019, 12 (07)
  • [38] Fault analysis of the 110 KV power grid with one-way power supply
    Karpov, Aleksei S.
    Fastiy, Galina P.
    Yaroshevich, Vera V.
    Ivonin, Viktor V.
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 206
  • [39] The Analysis of One Protection Action Caused by 110KV Line Break Fault
    Chang Yan-Li
    Chen Yan-Ping
    MODERN TECHNOLOGIES IN MATERIALS, MECHANICS AND INTELLIGENT SYSTEMS, 2014, 1049 : 613 - 616
  • [40] COMBINED MEDIUM-VOLTAGE PLANT FOR TRANSFORMER STATIONS WITH 110 KV (MEDIUM VOLTAGE) UP TO 7 FIELDS 110 KV
    MULLER, H
    THOSS, W
    ENERGIETECHNIK, 1984, 34 (11): : 425 - 426