A PERFORMANCE TEST RESULT OF CHORDAL TYPE FLOWMETER USING HIGH REYNOLDS NUMBER FACILITY IN NMIJ

被引:0
|
作者
Furuichi, Noriyuki [1 ]
Terao, Yoshiya [1 ]
Takamoto, Masaki [1 ]
机构
[1] AIST, Natl Metrol Inst Japan, Fluid Flow Div, Tsukuba, Ibaraki, Japan
来源
ICONE 17: PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, VOL 3 | 2009年
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In this paper, test result of two performance tests of the "Chordal Type" ultrasonic flowmeter made by Cameron inc. using NMIJ's high Reynolds number calibration facility will be presented. This type flowmeter have been introduced to nuclear power plant in USA to MUR uprating. First test is the investigation of the effect of the inner roughness of the upstream pipe. In this test, the difference of the K-factor, which is one of correction factors of a flowmeter, between Ra=1.7 (mm) and 14.2 (mm) is about 0.1%. To obtain the high efficiency of MUR uprating, actual flow calibration is recommended. Second test is the investigation of the relationship between "Profile Factor" and "Velocity Ratio". As a result, the correlation obtained by calibration for many upstream conditions at Re=3.0 x 10(6) can estimate "Profile Factor" at Re=1.4 x 10(7) within +/-0.25% However, the correlation with Reynolds number does not behave as expected by theorem. To obtain the correction factor of flowmeter with high accuracy and reliability, the actual flow calibration under the same Reynolds number at the actual plant condition is the only effective method.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 50 条
  • [11] PIV Characterization of High-Reynolds Flow in Turbine Test Facility
    Chikishev, L. M.
    Gobyzov, O. A.
    Sharaborin, D. K.
    Kravisov, Z. D.
    Dulin, V. M.
    Bilsky, A. V.
    Markovich, D. M.
    INTERNATIONAL CONFERENCE ON THE METHODS OF AEROPHYSICAL RESEARCH (ICMAR 2016), 2016, 1770
  • [12] Frequency detection in vortex flowmeter for low Reynolds number using piezoelectric sensor and installation effects
    Venugopal, A.
    Agrawal, Amit
    Prabhu, S. V.
    SENSORS AND ACTUATORS A-PHYSICAL, 2012, 184 : 78 - 85
  • [13] CICLoPE - A Large Pipe Facility for Detailed Turbulence Measurements at High Reynolds Number
    Rueedi, J. -D.
    Talamelli, A.
    Nagib, H. M.
    Alfredsson, P. H.
    Monkewitz, P. A.
    PROGRESS IN TURBULENCE III, 2010, 131 : 73 - +
  • [14] Electrical high-performance test facility
    不详
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1933, 77 : 1319 - 1319
  • [15] On High-Performance Airfoil at Very Low Reynolds Number
    Hirata, Katsuya
    Nozawa, Ryo
    Kondo, Shogo
    Onishi, Kazuki
    Tanigawa, Hirochika
    JOURNAL OF ROBOTICS AND MECHATRONICS, 2016, 28 (03) : 273 - 285
  • [16] SOME RESULTS FROM TESTS IN NAE HIGH REYNOLDS-NUMBER 2-DIMENSIONAL TEST FACILITY ON SHOCKLESS AND OTHER AIRFOILS
    OHMAN, LH
    KACPRZYN.JJ
    BROWN, D
    CANADIAN AERONAUTICS AND SPACE JOURNAL, 1973, 19 (06): : 297 - 312
  • [17] Numerical modelling of low-Reynolds number direct contact condensation in a suppression pool test facility
    Patel, G.
    Tanskanen, V.
    Kyrki-Rajamaki, R.
    ANNALS OF NUCLEAR ENERGY, 2014, 71 : 376 - 387
  • [18] Predictions of Morison type forces in irregular, high Reynolds number waves
    Moe, G
    Gudmestad, OT
    PROCEEDINGS OF THE SEVENTH (1997) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL III, 1997, 1997, : 399 - 406
  • [19] High Reynolds number magnetohydrodynamic turbulence using a Lagrangian model
    Graham, J. Pietarila
    Mininni, P. D.
    Pouquet, A.
    PHYSICAL REVIEW E, 2011, 84 (01):
  • [20] An unsteady RANS simulation of the performance of an oscillating hydrofoil at a high Reynolds number
    Wang, Hongliang
    Zheng, Xiaobo
    Proebsting, Stefan
    Hu, Changhong
    Wang, Qiang
    Li, Ye
    OCEAN ENGINEERING, 2023, 274