Assessment of test method variables for in vitro skin irritation testing of medical device extracts

被引:12
|
作者
Olsen, Daniel S. [1 ]
Lee, Michelle [1 ]
Turley, Audrey P. [1 ]
机构
[1] Nelson Labs LLC, Salt Lake City, UT 84123 USA
基金
美国国家卫生研究院;
关键词
Medical devices; Irritation; Alternative testing; In vitro; Reconstructed human epidermis;
D O I
10.1016/j.tiv.2017.11.012
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
Skin irritation is an important component of the biological safety evaluation of medical devices. This testing has typically been performed using in vivo models. However, in an effort to reduce the need for in vivo testing, alternative methods for assessing skin irritation potential in vitro have been developed using a Reconstructed Human Epidermis (RhE) model. During the development of the protocol for the round robin validation of in vitro irritation testing for medical device extracts, it became clear that there were three points in the procedure where different options may be validated within each laboratory for routine testing: sample exposure time (18 vs 24 h), SDS positive control concentration, and cytokine (IL-1 alpha) release testing. The goal of our study was to evaluate the effect of these variables. EpiDerm (TM) tissues were exposed to extracts of three plain polymer samples, and four polymers embedded with known irritant chemicals. Exposures were performed for 18 and 24 h. Resulting tissue viability was assessed by MIT reduction and IL-1 alpha release was assessed by ELISA. Testing was also performed using various concentrations of SDS ranging from 0.5 to 1% (w/v). Overall, results were similar for samples tested and 18 and 24 h, but the 18 h exposure time has the potential to have an impact on the results of some sample types. IL-1 alpha testing was shown to be useful to clarify conflicting tissue viability results. Use of a lower concentration of SDS as a positive control can help prevent issues that arise from excessive tissue damage often caused by 1% SDS.
引用
收藏
页码:426 / 432
页数:7
相关论文
共 50 条
  • [31] ChemSkin Reference Chemical Database for the Development of an In Vitro Skin Irritation Test
    Han, Juhee
    Lee, Ga-Young
    Bae, Green
    Kang, Mi-Jeong
    Lim, Kyung-Min
    TOXICS, 2021, 9 (11)
  • [32] Round Robin Study in Korea on alternative test method for evaluating skin irritation potential of medical devices
    Yi, J.
    Park, Y. S.
    Im, J. E.
    Moon, H. -W.
    Kim, J. H.
    Kim, K. J.
    Yoon, H. S.
    Lee, Y.
    Ko, H. J.
    Kim, I. S.
    Kim, J. S.
    Han, J. -S.
    Kim, Y.
    Kim, E. H.
    Yoe, K. -U.
    Coleman, K.
    TOXICOLOGY LETTERS, 2023, 384 : S270 - S270
  • [33] EVALUATION OF THE TEST METHOD FOR SKIN IRRITATION AS PRESCRIBED BY OECD AND EEC
    JACOBS, G
    MARTENS, M
    JOURNAL OF TOXICOLOGY-CUTANEOUS AND OCULAR TOXICOLOGY, 1987, 6 (03): : 215 - 225
  • [34] Application of a 4-h human patch test method for comparative and investigative assessment of skin irritation
    Robinson, MK
    Perkins, MA
    Basketter, DA
    CONTACT DERMATITIS, 1998, 38 (04) : 194 - 202
  • [35] Development of an in Vitro Test for the Skin Irritation Potential of Mild Surfactants and Its Validation Against Human Patch Testing.
    Shen, Hongwei
    O'Lenick, Anthony
    Jacobs, Fiona
    Treasure, Carol
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 2021, 98 : 208 - 209
  • [36] Evaluation of a quantitative clinical method for assessment of sensory skin irritation
    Robinson, MK
    Perkins, MA
    CONTACT DERMATITIS, 2001, 45 (04) : 205 - 213
  • [37] Pre-validation of an in vitro skin irritation test for medical devices using the reconstructed human tissue model EpiDerm™
    Helena, Kandarova
    Jamin, Willoughby A.
    Wim, De Jong H.
    Silvia, Letasiova
    Tatiana, Milasova
    Michael, Bachelor A.
    Bridget, Breyfogle
    Handa, Yuki
    Liset, De la Fonteyne
    Kelly, Coleman P.
    TOXICOLOGY IN VITRO, 2018, 50 : 407 - 417
  • [38] Development, optimization and validation of an in vitro skin irritation test for medical devices using the reconstructed human tissue model EpiDerm
    Kandarova, H.
    Willoughby, J.
    De Jong, W.
    Bachelor, M. A.
    Letasiova, S.
    Milasova, T.
    Breyfogle, B.
    de la Fonteyne, L.
    Haishima, Y.
    Ayehunie, S.
    Coleman, K.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2016, 136 (08) : B8 - B8
  • [39] Development, optimization and standardization of an in vitro skin irritation test for medical devices using the reconstructed human tissue model epiderm
    Kandarova, H.
    Willoughby, J.
    de Jong, W.
    Bachelor, M.
    Letasiova, S.
    Breyfogle, B.
    de la Fonteyne, L.
    Coleman, K.
    TOXICOLOGY LETTERS, 2015, 238 (02) : S351 - S352
  • [40] Development, optimization and validation of an in vitro skin irritation test for medical devices using the reconstructed human tissue model EpiDerm
    Kandarova, H.
    Willoughby, J. A.
    De Jong, W. H.
    Bachelor, M. A.
    Letasiova, S.
    Milasova, T.
    Breyfogle, B.
    De la Fonteyne, L.
    Haishima, Y.
    Coleman, K. P.
    TOXICOLOGY LETTERS, 2016, 258 : S63 - S63