Robust Sensing of Distal Pulse Waveforms on a Modified Weighing Scale for Ubiquitous Pulse Transit Time Measurement

被引:14
|
作者
Carek, Andrew M. [1 ]
Inan, Omer T. [1 ,2 ]
机构
[1] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
基金
美国国家卫生研究院;
关键词
Cardiovascular health; home monitoring; photoplethysmogram; pulse measurements; pulse transit time; BLOOD-PRESSURE; ARTERIAL STIFFNESS; VELOCITY; PHOTOPLETHYSMOGRAPHY; FORCE;
D O I
10.1109/TBCAS.2017.2683801
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The measurement of aortic pulse transit time (PTT), the time for the arterial pulse wave to travel from the carotid to the femoral artery, can provide valuable insight into cardiovascular health, specifically regarding arterial stiffness and blood pressure (BP). To measure aortic PTT, both proximal and distal arterial pulse timings are required. Recently, our group has demonstrated that the ballistocardiogram signal measured on a modified weighing scale can provide an unobtrusive, yet accurate, means of obtaining a proximal timing reference; however, there are no convenient, reliablemethods to extract the distal timing from a subject standing on themodified weighing scale. It is common to use a photoplethysmograph (PPG) attached to a toe to measure this distal pulse, but we discovered that this signal is greatly deteriorated as the subject stands on the scale. In this paper, we propose a novel method to measure the distal pulse using a custom reflective PPG array attached to the dorsum side of the foot (D-PPG). A total of 12 subjects of varying skin tones were recruited to assess the preliminary validation of this approach. Pulse measurements using the D-PPG were taken from seated and standing subjects, and the commercially available PPG were measured for facilitating comparison of timing measurements. We show that the D-PPG was the only sensor to retain the high detection rate of feasible timing values. To further test and optimize the system, various factors such as applied pressure, measurement location, and LED/photodiode configuration were tested.
引用
收藏
页码:765 / 772
页数:8
相关论文
共 50 条
  • [21] A NEW SYSTEM FOR MEASUREMENT OF THE PULSE TRANSIT TIME, THE PULSE WAVE VELOCITY AND ITS ANALYSIS
    Bereksi-Reguig, Anes.
    Bereksi-Reguig, F.
    Ali, A. Nait
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2017, 17 (01)
  • [22] Towards Ubiquitous Blood Pressure Monitoring in an Armband using Pulse Transit Time
    Toreyin, Hakan
    Javaid, Abdul Q.
    Ashouri, Hazar
    Ode, Oludotun
    Inan, Omer T.
    2015 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2015, : 560 - 563
  • [23] GENERAL ANESTHESIA PROLONGS MODIFIED PULSE WAVE TRANSIT TIME
    Yoshida, A.
    Terada, T.
    Okino, S.
    Muto, R.
    Sato, N.
    Ochiai, R.
    ANESTHESIA AND ANALGESIA, 2012, 114
  • [24] Low cost thermal measurement of pulse-transit-time
    James, M.
    Gregori, S.
    Fayek, D.
    2008 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-4, 2008, : 1684 - 1687
  • [25] Continuous Noninvasive blood pressure measurement by pulse transit time
    Fung, P
    Dumont, G
    Ries, C
    Mott, C
    Ansermino, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 738 - 741
  • [26] A Pulse Transit Time Measurement Method Based on Electrocardiography and Bioimpedance
    Bang, Suyoung
    Lee, Changik
    Park, Jinwoo
    Cho, Min-Chang
    Yoon, Young-Gyu
    Cho, SeongHwan
    2009 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS 2009), 2009, : 124 - +
  • [27] Measurement and Analysis of Local Pulse Transit Time for Emotion Recognition
    Beckmann, N.
    Viga, R.
    Doganguen, A.
    Grabmaier, A.
    IEEE SENSORS JOURNAL, 2019, 19 (17) : 7683 - 7692
  • [28] Unconstrained pulse transit time measurement system for computer users
    Park, Juwan
    Lim, Yongkyu
    Chee, Youngjoon
    Kim, Jungsoo
    Kim, Kokeun
    Park, Kwang Suk
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 3580 - 3582
  • [29] Robust Pulse Wave Velocity Estimation by Application of System Identification to Proximal and Distal Arterial Waveforms
    Xu, Da
    Ryan, Kathy L.
    Rickards, Caroline A.
    Zhang, Guanqun
    Convertino, Victor A.
    Mukkamala, Ramakrishna
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 3559 - 3562
  • [30] On Robust Extraction of Pulse Transit Time from Multimodal Pulsatile Signals
    Zhu, Yongwei
    Zhang, Haihong
    Guan, Cuntai
    2015 IEEE INTERNATIONAL CONFERENCE ON DIGITAL SIGNAL PROCESSING (DSP), 2015, : 403 - 406