A NEW SYSTEM FOR MEASUREMENT OF THE PULSE TRANSIT TIME, THE PULSE WAVE VELOCITY AND ITS ANALYSIS

被引:7
|
作者
Bereksi-Reguig, Anes. [1 ]
Bereksi-Reguig, F. [1 ]
Ali, A. Nait [2 ]
机构
[1] Univ Tlemcen, Fac Technol, Dept Biomed Engn, Biomed Engn Res Lab, Chetouane, Algeria
[2] Univ Paris Est, LISSI Lab, Creteil, France
关键词
Pulse wave velocity; heart rate variability; electrocardiogram; photoplethysmogram; regression models; HEART-RATE;
D O I
10.1142/S0219519417500105
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Arterial stiffness is a strong determinant of cardiovascular risk. Pulse wave velocity (PWV) is an index of arterial stiffness, and its prognostic value has been repeatedly emphasized. The work presented in this paper is concerned with the design of a new system for measurement of the PWV and analysis. It is in fact related to the description of the hardware setup and the software development in order to measure and analyze the PWV. In the proposed system, the determination of the PWV is carried out through the measurement of the pulse wave transit time (PWTT) using the electrocardiogram (ECG) and the photoplethysmogram (PPG) and the distance separating the site of ejection of the systolic pulse and the site of measuring the PPG signal. The hardware setup therefore consists of an optical device to detect the PPG and electrodes to detect ECG, and different boards to process and digitalize these signals to be acquired in the PC and analyzed. The developed software is concerned with first, the acquisition and processing of both ECG and PPG signals then the determination of the PWV and finally its analysis for different subjects and conditions. The analysis of the PWV is carried out for subjects of different ages in different physiological conditions according to heart activity. The obtained results show that there is a high correlation (r = 0.88), between heart rate variability (HRV) and PWV. They also show that PWV increases with age. The analysis of the PWV variations with age is also carried out through different regression models. The obtained result shows that the cubic regression model best fits these variations.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Measurement of aortic pulse wave velocity in CMR: comparison of transit time estimators
    Anas Dogui
    Alban Redheuil
    Muriel Lefort
    Alain Decesare
    Alain Herment
    Elie Mousseaux
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [2] Measurement of the Aortic Pulse Wave Velocity in MRI: Comparison of Transit Time Estimators
    Dogui, A.
    Kachenoura, N.
    Lefort, M.
    de Cesare, A.
    Frouin, F.
    Mousseaux, E.
    Herment, A.
    COMPUTING IN CARDIOLOGY 2010, VOL 37, 2010, 37 : 153 - 156
  • [3] Exact transit time measurement of the pulse wave with the mechanical pulse meter
    Braun, Thomas
    INNERE MEDIZIN, 2024, 65 : S12 - S13
  • [4] Arterial pulse transit time evaluation by peripheral pulse wave measurement
    Gircys, R.
    Kazanavicius, E.
    Obcarskas, L.
    JOURNAL OF MEASUREMENTS IN ENGINEERING, 2013, 1 (01) : 52 - 58
  • [5] Validation of a novel and existing algorithms for the estimation of pulse transit time: advancing the accuracy in pulse wave velocity measurement
    Vardoulis, Orestis
    Papaioannou, Theodore G.
    Stergiopulos, Nikolaos
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2013, 304 (11): : H1558 - H1567
  • [6] ESTIMATES OF PULSE-WAVE VELOCITY AND MEASUREMENT OF PULSE TRANSIT-TIME IN THE HUMAN CEREBRAL-CIRCULATION
    GILLER, CA
    AASLI, DR
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (02): : 101 - 105
  • [7] A new dual channel pulse wave velocity measurement system
    Chen, YK
    Wu, HT
    Chi, CK
    Tsai, WC
    Chen, JY
    Wang, MC
    BIBE 2004: FOURTH IEEE SYMPOSIUM ON BIOINFORMATICS AND BIOENGINEERING, PROCEEDINGS, 2004, : 17 - 21
  • [8] Determinants of hand pulse wave velocity and hand pulse transit time in healthy adults
    Chen, Yung-Sheng
    Lu, Wan-An
    Hsu, Ling-Yen
    Kuo, Cheng-Deng
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [9] A coronary pulse wave velocity measurement system
    Nam, Taewoo
    Cho, Jongrnan
    Choi, Junghyeon
    Park, Junho
    Cho, Wookhyun
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 975 - +
  • [10] Calculation and Validation of Continuous Pulse Transit Time Based on Normalized Pulse Wave Velocity
    Shin, Hangsik
    Choi, Ahyoung
    IEEE ACCESS, 2020, 8 : 221632 - 221639