Double-phase parathyroid technetium-99m-MIBI scintigraphy to identify functional autonomy in secondary hyperparathyroidism

被引:1
|
作者
Piga, M
Bolasco, P
Satta, L
Altieri, P
Loi, G
Nicolosi, A
Tarquini, A
Mariotti, S
机构
[1] UNIV CAGLIARI,DEPT NUCL MED,CAGLIARI,ITALY
[2] UNIV CAGLIARI,DEPT CLIN SURG,CAGLIARI,ITALY
[3] UNIV CAGLIARI,DEPT ENDOCRINOL,CAGLIARI,ITALY
[4] S MICHELE HOSP,DEPT DIALYSIS,CAGLIARI,ITALY
关键词
uremic secondary hyperparathyroidism; technetium-99m-MIBI; parathyroid hyperfunction; parathyroid hyperplasia;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Double-phase Tc-99m-methoxyisobutylisonitrile (MIBI) parathyroid scintigraphy has been proposed to detect hyperplastic parathyroid tissue, but the clinical usefulness of this technique in secondary hyperparathyroidism is still debated. Methods: Technetium-99m-MIBI parathyroid scintigraphy associated with parathyroid echography and [Tc-99m]pertechnetate thyroid scans were performed on 38 patients with chronic renal failure (CRF) and secondary hyperparathyroidism. In all patients, serum calcium, phosphorus, FT3, FT4, TSH, calcitonin and intact PTH (IPTH) were determined. Nine patients eventually underwent neck exploration and 28 parathyroid glands were removed. Results: Thyroid diseases were excluded in all patients. Echography revealed parathyroid enlargement in 22/38 (58%) patients, while MIBI scintigraphy was positive in 28/38 (74%), including 5-ectopic glands. Mean serum IPTH concentration was significantly higher in MIBI-positive patients compared to MIBI-negative patients. Mean echographic and surgical parathyroid size were significantly higher in MIBI-positive glands compared to MIBI-negative glands, but several discrepancies were observed in single patients. A significant positive correlation between serum IPTH and gland size was observed when MIBI-positive, but not MIBI-negative, parathyroids were considered. A paradoxical positive correlation between serum calcium and IPTH concentrations was found in MIBI-positive patients. Conclusion: Double-phase Tc-99m-MIBI scintigraphy is positive in the majority of patients with uremic hyperparathyroidism. Comparison of scintigraphic data with morphological and functional data strongly suggests that (TC)-T-99m-MIBI scans do not reveal simple parathyroid enlargement but rather, identify the presence of hyperfunctioning (autonomous) parathyroid tissue suggestive of tertiary hyperparathyroidism.
引用
收藏
页码:565 / 569
页数:5
相关论文
共 50 条
  • [21] Comparison of technetium-99m-MIBI, technetium-99m-tetrofosmin, ultrasound and MRI for localization of abnormal parathyroid glands
    Ishibashi, M
    Nishida, H
    Hiromatsu, Y
    Kojima, K
    Tabuchi, E
    Hayabuchi, N
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (02) : 320 - 324
  • [22] P-glycoprotein expression by technetium-99m-MIBI scintigraphy in hematologic malignancy
    Kostakoglu, L
    Guc, D
    Canpinar, H
    Kars, A
    Alper, E
    Kiratli, P
    Hayran, M
    Gündüz, U
    Kansu, E
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (07) : 1191 - 1197
  • [23] RAPID WASHOUT OF TECHNETIUM-99M-MIBI FROM A LARGE PARATHYROID ADENOMA - REPLY
    BENARD, F
    BISSON, G
    LEFEBVRE, B
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (10) : 1928 - 1929
  • [24] Multiple myeloma:: predictive value of technetium-99m-MIBI scintigraphy and MRI in the diagnosis and therapy
    Myslivecek, M
    Nekula, J
    Bacovsky, J
    Vytrasová, M
    Scudla, V
    Koranda, P
    Kaminek, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S276 - S276
  • [25] Tc-99m MIBI parathyroid scintigraphy and intact parathyroid hormone levels in hyperparathyroidism
    Hung, GU
    Wang, SJ
    Lin, WY
    CLINICAL NUCLEAR MEDICINE, 2003, 28 (03) : 180 - 185
  • [26] Double-phase Tc-99m sestamibi scintigraphy in a patient with uremia and secondary hyperparathyroidism an aid for subtotal parathyroidectomy
    Valli, N
    Leccia, F
    Pommereau, A
    Bordenave, L
    Laffon, E
    Ducassou, D
    CLINICAL NUCLEAR MEDICINE, 1999, 24 (03) : 189 - 191
  • [27] A head-to-head comparison between technetium-99m-tetrofosmin and technetium-99m-MIBI scintigraphy to evaluate suspicious breast lesions
    Reinhard Obwegeser
    Peter Berghammer
    Margarida Rodrigues
    Susanne Granegger
    Maria Hohlagschwandtner
    Herwig Kucera
    Christian Singer
    Andreas Berger
    Ernst Kubista
    Helmut Sinzinger
    European Journal of Nuclear Medicine, 1999, 26 : 1553 - 1559
  • [28] Predicting the effect of intravenous calcitriol on parathyroid gland activity using double-phase technetium Tc 99m-sestamibi scintigraphy
    Torregrosa, JV
    Fuster, D
    Ybarra, J
    Ortín, J
    Moreno, A
    Valveny, N
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2004, 44 (03) : 476 - 480
  • [29] Evaluating benign and malignant bone and soft-tissue lesions with technetium-99m-MIBI scintigraphy
    Taki, J
    Sumiya, H
    Tsuchiya, H
    Tomita, K
    Nonomura, A
    Tonami, N
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (04) : 501 - 506
  • [30] Comparison of parathyroid imaging with technetium-99m-pertechnetate/sestamibi subtraction, double-phase technetium-99m-sestamibi and technetium-99m-sestamibi SPECT
    Chen, CC
    Holder, LE
    Scovill, WA
    Tehan, AM
    Gann, DS
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (06) : 834 - 839