Double-phase parathyroid technetium-99m-MIBI scintigraphy to identify functional autonomy in secondary hyperparathyroidism

被引:1
|
作者
Piga, M
Bolasco, P
Satta, L
Altieri, P
Loi, G
Nicolosi, A
Tarquini, A
Mariotti, S
机构
[1] UNIV CAGLIARI,DEPT NUCL MED,CAGLIARI,ITALY
[2] UNIV CAGLIARI,DEPT CLIN SURG,CAGLIARI,ITALY
[3] UNIV CAGLIARI,DEPT ENDOCRINOL,CAGLIARI,ITALY
[4] S MICHELE HOSP,DEPT DIALYSIS,CAGLIARI,ITALY
关键词
uremic secondary hyperparathyroidism; technetium-99m-MIBI; parathyroid hyperfunction; parathyroid hyperplasia;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Double-phase Tc-99m-methoxyisobutylisonitrile (MIBI) parathyroid scintigraphy has been proposed to detect hyperplastic parathyroid tissue, but the clinical usefulness of this technique in secondary hyperparathyroidism is still debated. Methods: Technetium-99m-MIBI parathyroid scintigraphy associated with parathyroid echography and [Tc-99m]pertechnetate thyroid scans were performed on 38 patients with chronic renal failure (CRF) and secondary hyperparathyroidism. In all patients, serum calcium, phosphorus, FT3, FT4, TSH, calcitonin and intact PTH (IPTH) were determined. Nine patients eventually underwent neck exploration and 28 parathyroid glands were removed. Results: Thyroid diseases were excluded in all patients. Echography revealed parathyroid enlargement in 22/38 (58%) patients, while MIBI scintigraphy was positive in 28/38 (74%), including 5-ectopic glands. Mean serum IPTH concentration was significantly higher in MIBI-positive patients compared to MIBI-negative patients. Mean echographic and surgical parathyroid size were significantly higher in MIBI-positive glands compared to MIBI-negative glands, but several discrepancies were observed in single patients. A significant positive correlation between serum IPTH and gland size was observed when MIBI-positive, but not MIBI-negative, parathyroids were considered. A paradoxical positive correlation between serum calcium and IPTH concentrations was found in MIBI-positive patients. Conclusion: Double-phase Tc-99m-MIBI scintigraphy is positive in the majority of patients with uremic hyperparathyroidism. Comparison of scintigraphic data with morphological and functional data strongly suggests that (TC)-T-99m-MIBI scans do not reveal simple parathyroid enlargement but rather, identify the presence of hyperfunctioning (autonomous) parathyroid tissue suggestive of tertiary hyperparathyroidism.
引用
收藏
页码:565 / 569
页数:5
相关论文
共 50 条
  • [11] Long-term intravenous calcitriol in secondary hyperparathyroidism: The role of technetium-99m-MIBI scintigraphy in predicting the response to treatment
    Owda, AK
    Mousa, D
    Abdallah, AH
    Hawas, FA
    Al-Harbi, W
    Fedail, H
    Al-Shoail, G
    Al-Sulaiman, MH
    Al-Khader, AA
    RENAL FAILURE, 2002, 24 (02) : 165 - 173
  • [12] RAPID WASHOUT OF TECHNETIUM-99M-MIBI FROM A LARGE PARATHYROID ADENOMA
    BENARD, F
    LEFEBVRE, B
    BEUVON, F
    LANGLOIS, MF
    BISSON, G
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (02) : 241 - 243
  • [13] 99m-MIBI parathyroid scintigraphy in secondary hyperparathyroidism : Usefulness of SPECT/CT
    Slim, I.
    Mhiri, A., I
    Meddeb, I.
    Ben Sellem, D.
    Zaabar, L.
    Yeddes, I.
    Letaief, B.
    Ben Slimene, M. F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S393 - S393
  • [14] Double-phase scintigraphy at 99m Tc MIBI or dual scintigraphy at 99mTc/99mTc MIBI for the diagnosis of associated parathyroid or thyroid pathologies?
    Stefanescu, C.
    Rusu, V.
    Rusu, M.
    Vulpoi, C.
    Mogos, V.
    Zbranca, E.
    DIABETES & METABOLISM, 2007, 33 : S139 - S139
  • [15] Has double-phase MIBI scintigraphy usefulness in the diagnosis of hyperparathyroidism?
    Torregrosa, JV
    Palomar, MR
    Pons, F
    Sabater, L
    Gilabert, R
    Llovera, J
    Fernandez-Cruz, L
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 : 37 - 40
  • [16] Evaluation of technetium-99m-MIBI scintigraphy in metastatic differentiated thyroid carcinoma
    Miyamoto, S
    Kasagi, K
    Misaki, T
    Alam, MS
    Konishi, J
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (03) : 352 - 356
  • [17] Technetium-99m-MIBI scintigraphy of thyroid nodules in an endemic goiter area
    Kresnik, E
    Gallowitsch, HJ
    Mikosch, P
    Gomez, I
    Lind, P
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (01) : 62 - 65
  • [18] Technetium-99m-MIBI scintigraphy in the assessment of neoadjuvant chemotherapy in breast carcinoma
    Maini, CL
    Tofani, A
    Sciuto, R
    Semprebene, A
    Cavaliere, R
    Mottolese, M
    Benevolo, M
    Ferranti, F
    Grandinetti, ML
    Vici, P
    Lopez, M
    Botti, C
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (10) : 1546 - 1551
  • [19] Preoperative localization of parathyroid lesions in hyperparathyroidism: Relationship between Technetium-99m-MIBI uptake and oxyphil cell content
    Carpentier, A
    Jeannotte, S
    Verreault, J
    Lefebvre, B
    Bisson, G
    Mongeau, CJ
    Maheux, P
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (08) : 1441 - 1444
  • [20] Technetium-99m-MIBI and thallium-201 scintigraphy of primary lung cancer
    Nishiyama, Y
    Kawasaki, Y
    Yamamoto, Y
    Fukunaga, K
    Satoh, K
    Takashima, H
    Ohkawa, M
    Tanabe, M
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (09) : 1358 - 1361