Calibration transfer of near infrared spectrometers for the assessment of plasma ethanol precipitation process

被引:10
|
作者
Sun, Zhongyu [1 ,2 ]
Wang, Jiayue [1 ,2 ]
Nie, Lei [3 ]
Li, Lian [4 ]
Cao, Dawei [5 ]
Fan, Jiajin [5 ]
Wang, Haiyan [1 ,2 ]
Liu, Ruichen [1 ,2 ]
Zhang, Yinran [6 ]
Zang, Hengchang [1 ,2 ]
机构
[1] Shandong Univ, Sch Pharmaceut Sci, Wenhuaxi Rd 44, Jinan 250012, Shandong, Peoples R China
[2] Shandong Univ, Natl Glycoengn Res Ctr, Wenhuaxi Rd 44, Jinan 250012, Shandong, Peoples R China
[3] Shandong Univ, Sch Pharmaceut Sci & Pharmaceut Anal, Wenhuaxi Rd 44, Jinan 250012, Shandong, Peoples R China
[4] Shandong Univ, Sch Basic Med Sci, Wenhuaxi Rd 44, Jinan 250012, Shandong, Peoples R China
[5] Shandong Taibang Biol Prod Ltd Co, East Hushan Rd 14, Tai An 271000, Shandong, Peoples R China
[6] Ohio State Univ, Dept Chem & Biochem, Newman & Wolfram Lab, 100 West 18th Ave, Columbus, OH 43210 USA
基金
美国国家科学基金会;
关键词
Calibration transfer; Plasma ethanol precipitation; Near infrared spectroscopy (NIRS); Piecewise reverse standardization (PRS); Rank sample set partitioning based on joint x-y distance (Rank-SPXY); Process analytical technology (PAT); MULTIVARIATE CALIBRATION; CORRELATION-COEFFICIENT; ALCOHOL PRECIPITATION; FOURIER-TRANSFORM; NIR SPECTRA; MICRO-NIR; STANDARDIZATION; QUALITY; SPECTROSCOPY; INSTRUMENTS;
D O I
10.1016/j.chemolab.2018.08.012
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Plasma ethanol precipitation process is an important step in the biopharmacy production process, and near infrared spectroscopy (NIBS) is an effective process analytical technology (PAT) tool in detecting the key quality attribute: the total protein (TP) content. But establishing a robust model is pretty complex. The aim of this study was to explore the calibration transfer strategy between master and slave spectrometers with the biopharmacy. Firstly, 8 batches of ethanol precipitation process were experimented. The changing spectra were collected by two spectrometers, reference values were measured by biuret method. Then, calibration transfer based on the PRS algorithm was carried out. Finally, before establishment of the optimal TP content partial least squares regression (PLSR) model of calibration transfer, rank sample set partitioning based on joint x-y distance (Rank-SPXY) and spectral pretreatment methods were selected after comparison. The determination coefficients of prediction (R-p(2)) and root mean squares error of prediction (RMSEP) were 0.934 and 0.8395 g/L, respectively. The results showed that Rank-SPXY-PRS was an effective calibration transfer strategy with different NIBS spectrometers. To some extent, the predictive capability of PLSR model was improved after calibration transfer, and it could provide reference for the further research in biopharmacy production process.
引用
收藏
页码:64 / 71
页数:8
相关论文
共 50 条
  • [31] Near-infrared calibration transfer based on spectral regression
    Peng, Jiangtao
    Peng, Silong
    Jiang, An
    Tan, Jie
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2011, 78 (04) : 1315 - 1320
  • [32] Rapid determination of immunoglobulin G concentration in cold ethanol Precipitation process of raw plasma with near-infrared spectroscopy (vol 116, pg 370, 2013)
    Zhang, Hui
    Liu, Aihua
    Zang, Hengchang
    Li, Hu
    Jiang, Wei
    Li, Lian
    Wang, Jinfeng
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2014, 117 : 823 - 823
  • [33] Content uniformity determination of pharmaceutical tablets using five near-infrared reflectance spectrometers: A process analytical technology (PAT) approach using robust multivariate calibration transfer algorithms
    Sulub, Yusuf
    LoBrutto, Rosario
    Vivilecchia, Richard
    Wabuyele, Busolo Wa
    ANALYTICA CHIMICA ACTA, 2008, 611 (02) : 143 - 150
  • [34] A SIMPLE INTERNAL MODULATION TECHNIQUE FOR THE SPECTRAL CALIBRATION OF CIRCULAR VARIABLE FILTER SPECTROMETERS IN THE NEAR-INFRARED
    CHANDRASEKHAR, T
    ASHOK, NM
    BHATT, HC
    MANIAN, KSB
    INFRARED PHYSICS, 1984, 24 (06): : 571 - 572
  • [35] Refining transfer set in calibration transfer of near infrared spectra by backward refinement of samples
    Zheng, Kaiyi
    Feng, Tao
    Zhang, Wen
    Huang, Xiaowei
    Li, Zhihua
    Zhang, Di
    Shi, Jieyong
    Marunaka, Yoshinori
    Zou, Xiaobo
    ANALYTICAL METHODS, 2020, 12 (11) : 1495 - 1503
  • [36] Near-infrared calibration transfer via support vector machine and transfer learning
    Yu Binfeng
    Ji Haibo
    ANALYTICAL METHODS, 2015, 7 (06) : 2714 - 2725
  • [37] Application of DS algorithm to the calibration transfer in near-infrared spectroscopy
    Li Qing-bo
    Zhang Guang-jun
    Xu Ke-xin
    Wang Yan
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27 (05) : 873 - 876
  • [38] Application of DS algorithm to the calibration transfer in near-infrared spectroscopy
    Li, Qing-Bo
    Zhang, Guang-Jun
    Xu, Ke-Xin
    Wang, Yan
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2007, 27 (05): : 873 - 876
  • [39] Spectral simulation methodology for calibration transfer of near-infrared spectra
    Sulub, Yusuf
    Small, Gary W.
    APPLIED SPECTROSCOPY, 2007, 61 (04) : 406 - 413
  • [40] Transfer of multivariate classification models between laboratory and process near-infrared spectrometers for the discrimination of green Arabica and Robusta coffee beans
    Myles, Anthony J.
    Zimmerman, Tyler A.
    Brown, Steven D.
    APPLIED SPECTROSCOPY, 2006, 60 (10) : 1198 - 1203