Evaluation of the long-term stability for the cylindrical ionization chambers

被引:0
|
作者
Lah, J.
Lim, C.
Suh, T.
机构
[1] Catholic Univ, Seoul, South Korea
[2] Korea Food & Drug Admin, Seoul, South Korea
关键词
D O I
10.1118/1.2760880
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To analyze the long‐term stability of Farmer‐type cylindrical ionization chambers using the calibration factor provided by the KFDA (Korea Food and Drug Administration). KFDA is the national secondary standard laboratory (SSDL) in Korea and approve as a member of the IAEA SSDL network. Materials and Methods: The cylindrical ionization chambers used in this study include PTW 30001(30006), 30013, 30002, 30004, 23333, Capintec PR06C, NE 2571, Exradin A12 and Wellhofer FC65G(IC70). The Nk and ND,W calibration factors for the cylindrical chambers were analyzed and the measured ND,W was compared with the calculated ND,W calibration factor. Results: The long‐term stability of PTW 30013(30006), Wellhofer FC65G(IC70) and NE 2571 varied within 0.2 %, meaning that they are more stable than other ionization chambers. This result is different from previous ones showing that the long term stability of ionization chambers with graphite wall material was superior to ionization chambers made of PMMA material. It turns out that almost the same levels of the stability of calibration factor were shown between PTW 30013(30006) ionization chamber made of PMMA wall material and Wellhofer FC65G(IC70) ionization chambers made of graphite material, and thus the former is shown to be superior from the aspect of long‐term safety, and PMMA wall material is firmer, more convenient to use, and it is more effective from the financial aspect. Therefore, it may be considered to be more appropriate to use for the regular dose measurements in comparison with graphite type ionization chamber. The measured ND,W calibration factor was approximately 1.0% higher than the calculated ND,W that was determined using the Nk calibration factor. Conclusion: The long‐term stability of the cylindrical chambers was evaluated using the Nk and ND,W calibration factor. It should help to improve clinical electron dosimetry in radiotherapy. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2452 / 2452
页数:1
相关论文
共 50 条
  • [31] Long-term stability of slopes
    Ter-Martirosian, Z. G.
    Proshin, M. V.
    Proceedings of the 16th International Conference on Soil Mechanics and Geotechnical Engineering, Vols 1-5: GEOTECHNOLOGY IN HARMONY WITH THE GLOBAL ENVIRONMENT, 2005, : 2587 - 2590
  • [32] Long-term stability - Comment
    Arnone, R
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1996, 109 (02) : A17 - A18
  • [33] Investigation of anomalous recombination behaviour in cylindrical ionization chambers
    Lalonde, M
    McCaffrey, J
    McEwen, M
    MEDICAL PHYSICS, 2005, 32 (06) : 2006 - 2006
  • [34] Evaluation of the long-term storage stability of saliva as a source of human DNA
    Robert P. Anthonappa
    Nigel M. King
    A. Bakr M. Rabie
    Clinical Oral Investigations, 2013, 17 : 1719 - 1725
  • [35] Evaluation of long-term stability in second metatarsal reconstruction of the temporomandibular joint
    Landa, LE
    Gordon, C
    Dahar, N
    Sotereanos, GC
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2003, 61 (01) : 65 - 71
  • [36] Evaluation of the long-term storage stability of saliva as a source of human DNA
    Anthonappa, Robert P.
    King, Nigel M.
    Rabie, A. Bakr M.
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (07) : 1719 - 1725
  • [37] Evaluation of long-term stability for high arch dam and its application
    Liu, Y. R.
    He, Z.
    Yang, Q.
    Pan, Y. W.
    Zhang, L.
    Xue, L. J.
    COMPUTER METHODS AND RECENT ADVANCES IN GEOMECHANICS, 2015, : 1943 - 1948
  • [38] Probabilistic Evaluation of Long-term Stability Considering Secondary Contingency Scenarios
    Do, Duy-Phuong N.
    Oh, Ungjin
    Lee, Yeonchan
    Choi, Jaeseok
    Trung-Tinh Tran
    2016 INTERNATIONAL CONFERENCE ON PROBABILISTIC METHODS APPLIED TO POWER SYSTEMS (PMAPS), 2016,
  • [39] Evaluation of long-term stability and degradation of polycarbonate based plastic glass
    Ito, Mikiya
    Masuda, Yoshihiro
    Nagai, Kazukiyo
    JOURNAL OF POLYMER ENGINEERING, 2015, 35 (01) : 31 - 40
  • [40] Long-term evaluation of the stability of reconstructed condyles by transport distraction osteogenesis
    Xiao, E.
    Zhang, Y.
    An, J.
    Li, J.
    Yan, Y.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 41 (12) : 1490 - 1494