Comparison of Long-Wave and Mid-Wave Infrared Imaging Modalities for Photothermal Coherence Tomography of Human Teeth

被引:6
|
作者
Thapa, Damber [1 ]
Welch, Robert [2 ]
Dabas, Rimple Poonia [1 ]
Salimi, Mohammahhossein [1 ]
Tavakolian, Pantea [2 ]
Sivagurunathan, Koneswaran [2 ,3 ,4 ]
Ngai, Kimberly [5 ,6 ]
Huang, Bo [5 ,6 ]
Finer, Yoav [5 ,6 ]
Abrams, Stephen [4 ]
Mandelis, Andreas [2 ,3 ,4 ]
Tabatabaei, Nima [7 ]
机构
[1] York Univ, Dept Mech Engn, N York, ON, Canada
[2] Univ Toronto, Dept Mech & Ind Engn, Ctr Adv Diffus Wave & Photoacoust Technol CADIPT, Toronto, ON M5S 1A1, Canada
[3] Inst Adv Nondestruct & Noninvas Diagnost Technol, Toronto, ON M5S 3G8, Canada
[4] Quantum Dent Technol, Toronto, ON M6B 1L3, Canada
[5] Univ Toronto, Fac Dent, Toronto, ON, Canada
[6] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON, Canada
[7] York Univ, Dept Mech Engn, Toronto, ON M3J 1P3, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
Dentistry; Teeth; Tomography; Imaging; Cameras; Visualization; Microorganisms; Dental caries detection; active thermography; enhanced truncated-correlation photothermal coherence tomography; non-invasive dental imaging; infrared camera; CARIES; QUANTIFICATION; VALIDATION; ENAMEL; DENTIN;
D O I
10.1109/TBME.2022.3153209
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The ability to detect dental caries at early stages lies at the heart of minimal intervention dentistry, enabling the curing or arresting of carious lesions before they advance to the cavity stage. Enhanced truncated-correlation photothermal coherence tomography (eTC-PCT) using mid-wave infrared (MWIR) cameras has recently been shown to offer tomographic visualization of early caries. The tomographic slicing ability of such systems, however, is believed to be limited by direct radiative thermal emission through the translucent dental enamel in the 3-5 mu m MWIR spectral range. Such radiative emissions can dominate the delayed conductive thermal contributions needed for tomographic reconstruction of internal dental defects. It has been hypothesized that long-wave infrared (LWIR) eTC-PCT systems may offer better tomographic performance by taking advantage of the intrinsic attenuation of direct radiative emission by dental enamel in the LWIR spectral range, enabling more effective delayed conductive thermal contributions from subsurface caries. More than an order of magnitude lower cost of the system is another key attribute of LWIR eTC-PCT which can open the door for downstream translation of the technology to clinics. In this report, we offer a systematic comparison of the performance/effectiveness of caries detection with LWIR and MWIR eTC-PCT systems for detecting natural caries, bacterial caries, and artificially demineralized enamel surfaces. Our results suggest that the low-cost LWIR based eTC-PCT system provides 3D visualization and 2D slice-by-slice images of early caries and internal micro-cracks similar to those obtained from the more expensive MWIR-based eTC-PCT system, albeit with similar to 1.3dB lower signal-to-noise ratio.
引用
收藏
页码:2755 / 2766
页数:12
相关论文
共 50 条
  • [41] Mid-wave/long-wave dual-color infrared quantum cascade detector enhanced by antenna-coupled microcavity
    Zhu, Yixuan
    Zhai, Shenqiang
    Liu, Junqi
    Li, Kun
    Yang, Ke
    Liu, Shuman
    Zhang, Jinchuan
    Zhuo, Ning
    Wang, Lijun
    Liu, Fengqi
    OPTICS EXPRESS, 2021, 29 (23) : 37327 - 37335
  • [42] The bulk generation-recombination processes and the carrier lifetime in mid-wave infrared and long-wave infrared liquid nitrogen cooled HgCdTe alloys
    Jozwikowski, K.
    Kopytko, M.
    Rogalski, A.
    JOURNAL OF APPLIED PHYSICS, 2012, 112 (03)
  • [43] Performance characteristics of high-purity mid-wave and long-wave infrared type-II InAs/GaSb superlattice infrared photodiodes
    Hood, Andrew
    Razeghi, Manijeh
    Nathan, Vaidya
    Tidrow, Meimei Z.
    QUANTUM SENSING AND NANOPHOTONIC DEVICES III, 2006, 6127
  • [44] Mid-wave infrared spatial heterodyne interference imaging spectrometer
    Li Siliang
    Ding Yi
    Li Zhiwei
    Shi Hailiang
    Xiong Wei
    Luo Haiyan
    SEVENTH SYMPOSIUM ON NOVEL PHOTOELECTRONIC DETECTION TECHNOLOGY AND APPLICATIONS, 2021, 11763
  • [45] Long, mid-wave infrared detector with time delayed integration
    Zucker, M
    Pivnik, I
    Malkinson, E
    Haski, J
    Reiner, T
    Admon, D
    Keinan, M
    Yassen, M
    Sapiro, I
    Bykov, L
    Sapir, N
    Fraenkel, A
    INFRARED TECHNOLOGY AND APPLICATIONS XXV111, PTS 1 AND 2, 2003, 4820 : 580 - 592
  • [46] Athermal design for mid-wave infrared lens with long EFFL
    Bai Yu
    Xing Tingwen
    ADVANCED OPTICAL MANUFACTURING TECHNOLOGIES, 2016, 9683
  • [47] Compressive Spectroscopic Long-Wave Infrared Imaging
    Charsley, Jake M.
    Rutkauskas, Marius
    Altmann, Yoann
    Smith, Margaret
    Young, Christina
    Reid, Derryck T.
    2021 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE & EUROPEAN QUANTUM ELECTRONICS CONFERENCE (CLEO/EUROPE-EQEC), 2021,
  • [48] Comparison of nBn and nBp mid-wave barrier infrared photodetectors
    Klem, J. F.
    Kim, J. K.
    Cich, M. J.
    Hawkins, S. D.
    Fortune, T. R.
    Rienstra, J. L.
    QUANTUM SENSING AND NANOPHOTONIC DEVICES VII, 2010, 7608
  • [49] Compressive Spectroscopic Long-Wave Infrared Imaging
    Charsley, Jake M.
    Rutkauskas, Marius
    Altmann, Yoann
    Smith, Margaret
    Young, Christina
    Reid, Derryck T.
    2021 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2021,
  • [50] Antimonides T2SL Mid-Wave and Long-Wave Infrared Focal Plane Arrays for Earth Remote Sensing Applications
    Gunapala, Sarath
    Ting, David
    Rafol, Sir
    Soibel, Alexander
    Khoshakhlagh, Arezou
    Keo, Sam
    Pepper, Brian
    Fisher, Anita
    Hill, Cory
    Pagano, Thomas
    Lucey, Paul
    Wright, Robert
    Nunes, Miguel
    Flynn, Luke
    Babu, Sachidananda
    Ghuman, Parminder
    QUANTUM SENSING AND NANO ELECTRONICS AND PHOTONICS XVII, 2020, 11288