Comparison of Long-Wave and Mid-Wave Infrared Imaging Modalities for Photothermal Coherence Tomography of Human Teeth

被引:6
|
作者
Thapa, Damber [1 ]
Welch, Robert [2 ]
Dabas, Rimple Poonia [1 ]
Salimi, Mohammahhossein [1 ]
Tavakolian, Pantea [2 ]
Sivagurunathan, Koneswaran [2 ,3 ,4 ]
Ngai, Kimberly [5 ,6 ]
Huang, Bo [5 ,6 ]
Finer, Yoav [5 ,6 ]
Abrams, Stephen [4 ]
Mandelis, Andreas [2 ,3 ,4 ]
Tabatabaei, Nima [7 ]
机构
[1] York Univ, Dept Mech Engn, N York, ON, Canada
[2] Univ Toronto, Dept Mech & Ind Engn, Ctr Adv Diffus Wave & Photoacoust Technol CADIPT, Toronto, ON M5S 1A1, Canada
[3] Inst Adv Nondestruct & Noninvas Diagnost Technol, Toronto, ON M5S 3G8, Canada
[4] Quantum Dent Technol, Toronto, ON M6B 1L3, Canada
[5] Univ Toronto, Fac Dent, Toronto, ON, Canada
[6] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON, Canada
[7] York Univ, Dept Mech Engn, Toronto, ON M3J 1P3, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
Dentistry; Teeth; Tomography; Imaging; Cameras; Visualization; Microorganisms; Dental caries detection; active thermography; enhanced truncated-correlation photothermal coherence tomography; non-invasive dental imaging; infrared camera; CARIES; QUANTIFICATION; VALIDATION; ENAMEL; DENTIN;
D O I
10.1109/TBME.2022.3153209
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The ability to detect dental caries at early stages lies at the heart of minimal intervention dentistry, enabling the curing or arresting of carious lesions before they advance to the cavity stage. Enhanced truncated-correlation photothermal coherence tomography (eTC-PCT) using mid-wave infrared (MWIR) cameras has recently been shown to offer tomographic visualization of early caries. The tomographic slicing ability of such systems, however, is believed to be limited by direct radiative thermal emission through the translucent dental enamel in the 3-5 mu m MWIR spectral range. Such radiative emissions can dominate the delayed conductive thermal contributions needed for tomographic reconstruction of internal dental defects. It has been hypothesized that long-wave infrared (LWIR) eTC-PCT systems may offer better tomographic performance by taking advantage of the intrinsic attenuation of direct radiative emission by dental enamel in the LWIR spectral range, enabling more effective delayed conductive thermal contributions from subsurface caries. More than an order of magnitude lower cost of the system is another key attribute of LWIR eTC-PCT which can open the door for downstream translation of the technology to clinics. In this report, we offer a systematic comparison of the performance/effectiveness of caries detection with LWIR and MWIR eTC-PCT systems for detecting natural caries, bacterial caries, and artificially demineralized enamel surfaces. Our results suggest that the low-cost LWIR based eTC-PCT system provides 3D visualization and 2D slice-by-slice images of early caries and internal micro-cracks similar to those obtained from the more expensive MWIR-based eTC-PCT system, albeit with similar to 1.3dB lower signal-to-noise ratio.
引用
收藏
页码:2755 / 2766
页数:12
相关论文
共 50 条
  • [21] Optical design of dual-mode seeker for long-wave infrared and mid-wave infrared seeker in missile application
    Sakarya, Dogan Ugur
    OPTICAL MODELING AND PERFORMANCE PREDICTIONS X, 2018, 10743
  • [22] Comparison of modeled atmosphere-dependent range performance of long-wave and mid-wave IR imagers
    Dhar, Vikram
    Khan, Zafar
    INFRARED PHYSICS & TECHNOLOGY, 2008, 51 (06) : 520 - 527
  • [23] Long-wave and mid-wave infrared micro-bolometers with gold black or wavelength-selective absorbers
    Peale, Robert E.
    IMAGE SENSING TECHNOLOGIES: MATERIALS, DEVICES, SYSTEMS, AND APPLICATIONS V, 2018, 10656
  • [24] Robust multimaterial tellurium-based chalcogenide glass fibers for mid-wave and long-wave infrared transmission
    Tao, Guangming
    Shabahang, Soroush
    Ren, He
    Khalilzadeh-Rezaie, Farnood
    Peale, Robert E.
    Yang, Zhiyong
    Wang, Xunsi
    Abouraddy, Ayman F.
    OPTICS LETTERS, 2014, 39 (13) : 4009 - 4012
  • [25] Mid-Wave and Long-Wave Infrared Signature Model and Measurements of Power Lines Against Atmospheric Path Radiance
    Leslie, Patrick
    Furxhi, Orges
    Short, Robert
    Grimming, Robert
    Driggers, Ronals
    2021 IEEE RESEARCH AND APPLICATIONS OF PHOTONICS IN DEFENSE CONFERENCE (RAPID), 2021,
  • [26] Qualitative Comparison of Lock-in Thermography (LIT) and Pulse Phase Thermography (PPT) in Mid-Wave and Long-Wave Infrared for the Inspection of Paintings
    Hillen, Michael
    Sels, Seppe
    Ribbens, Bart
    Verspeek, Simon
    Janssens, Koen
    van der Snickt, Geert
    Steenackers, Gunther
    APPLIED SCIENCES-BASEL, 2023, 13 (07):
  • [27] Mid-wave and long-wave infrared signature model and measurement of power lines against atmospheric path radiance
    Leslie, Patrick
    Furxhi, Orges
    Short, Robert
    Grimming, Robert
    Driggers, Ronals
    OPTICS EXPRESS, 2022, 30 (01) : 563 - 575
  • [28] Active Mid-Wave to Long-Wave Supercontinuum FTIR Sensor for Standoff Chemical Detection
    Martinez, Ramon A.
    Guo, Kaiwen
    Zhai, Tianqu
    Terry, Fred L.
    Pierce, Leland E.
    Islam, Mohammed N.
    Gibson, Ricky
    Reed, Jennifer M.
    Bedford, Robert G.
    Maksymiuk, Lukasz
    Freeman, Michael J.
    Gorin, Brian A.
    Christian, Noah P.
    Ifarraguerri, Agustin I.
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2019, 37 (14) : 3626 - 3636
  • [29] All-silicon polarization-independent broadband achromatic metalens designed for the mid-wave and long-wave infrared
    Yue, Song
    Liu, Yuxin
    Wang, Ran
    Shi, Haiyan
    Feng, Yanming
    Wen, Zhidong
    Zhang, Zichen
    OPTICS EXPRESS, 2023, 31 (26) : 44340 - 44352
  • [30] Dual band mid-wave/long-wave IR source for atmospheric remote sensing
    Vachss, F
    Norman, J
    Turner, C
    AIR MONITORING AND DETECTION OF CHEMICAL AND BIOLOGICAL AGENTS, 1999, 3533 : 174 - 179