Thermodynamic analysis and comparison of a novel dual-ejector based organic flash combined power and refrigeration cycle driven by the low-grade heat source

被引:38
|
作者
Tang, Zuohang [1 ]
Wu, Chuang [1 ]
Liu, Chao [1 ]
Xu, Xiaoxiao [1 ]
Liu, Jiangyan [1 ]
机构
[1] Chongqing Univ, Sch Energy & Power Engn, Minist Educ, Key Lab Lowgrade Energy Utilizat Technol & Syst, Chongqing 400044, Peoples R China
关键词
Combined power and refrigeration cycle; Organic flash cycle; Ejector; Low-grade heat source; THERMOECONOMIC ANALYSIS; CARBON-DIOXIDE; RANKINE-CYCLE; KALINA CYCLE; RECOVERY; DESIGN; OFC; OPTIMIZATION; PROPOSAL; ORC;
D O I
10.1016/j.enconman.2021.114205
中图分类号
O414.1 [热力学];
学科分类号
摘要
This proposes a novel dual-ejector based organic flash combined power and refrigeration cycle, which replaces the two throttle valves with two ejectors for the basic flash cycle, to provide power and cooling simultaneously for users. Detailed mathematical models of the proposed system are built and validated. The preliminary analysis results show that the exergy efficiency reaches 45.59% under geothermal water at 150celcius. Then a parametric analysis is conducted to investigate the effects of five key parameters on system performance. The results show that both an optimal flash pressure and an extraction pressure exist to maximize the exergy efficiency. Finally, the proposed cycle, the separated power and refrigeration cycle consisting of a basic organic flash cycle and an ejector refrigeration cycle, and the basic organic flash cycle are optimized and compared by examining seven different organic fluids such as R245fa, R141b, R123, R245ca, R601, R365mfc, and R600. The results show that the R245fa brings the highest exergy efficiency to both the proposed cycle and organic flash cycle among seven involved organic fluids. Compared with the basic organic flash cycle, the proposed cycle with R245fa has a 4.91% percentage point higher exergy efficiency, 10.44% higher net power output, and an extra 172.6 kW of refrigeration output. Meanwhile, the optimal exergy efficiency and net power output of the proposed cycle are 5.82-6.80% percentage point higher and 15.06-23.87% higher than those of the separated power and refrigeration cycle. An exergy analysis suggests that the throttling losses are indeed significantly reduced by replacing the throttle valves with the ejectors for the organic flash cycle.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Thermodynamic performance analysis a power and cooling generation system based on geothermal flash, organic Rankine cycles, and ejector refrigeration cycle; application of zeotropic mixtures
    Wang, Nan
    Zhang, Su
    Fei, Zhibin
    Zhang, Wei
    Shao, Limin
    Sardari, Farshid
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2020, 40 (40)
  • [42] Thermodynamic analysis and optimization of a partial evaporating dual-pressure organic rankine cycle system for low-grade heat recovery
    Li, Dantong
    He, Zhilong
    Wang, Qi
    Wang, Xiaolin
    Wu, Weifeng
    Xing, Ziwen
    APPLIED THERMAL ENGINEERING, 2021, 185
  • [43] A novel cycle engine for low-grade heat utilization: Principle, conceptual design and thermodynamic analysis
    Luo, Baojun
    Xiang, Quanwei
    Su, Xiaoxue
    Zhang, Shunfeng
    Yan, Piaopiao
    Liu, Jingping
    Li, Ruijie
    ENERGY, 2024, 301
  • [44] Exergoeconomic and Exergoenvironmental Analysis of a Novel Power and Cooling Cogeneration System Based on Organic Rankine Cycle and Ejector Refrigeration Cycle
    Tao, Jinke
    Wang, Huitao
    Wang, Jianjun
    Feng, Chaojun
    ENERGIES, 2022, 15 (21)
  • [45] Thermodynamic analysis and optimization of an (organic Rankine cycle) ORC using low grade heat source
    Wang, Jiangfeng
    Yan, Zhequan
    Wang, Man
    Ma, Shaolin
    Dai, Yiping
    ENERGY, 2013, 49 : 356 - 365
  • [46] Thermodynamic analysis of a novel compact power generation and waste heat operated absorption, ejector-jet pump refrigeration cycle
    Anil Kumar
    Raj Kumar
    Journal of Mechanical Science and Technology, 2014, 28 : 3895 - 3902
  • [47] Thermodynamic analysis of a novel compact power generation and waste heat operated absorption, ejector-jet pump refrigeration cycle
    Kumar, Anil
    Kumar, Raj
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2014, 28 (09) : 3895 - 3902
  • [48] Situation Analysis of Organic Rankine Cycle system for low-grade heat power generation in China
    Liao Yongxi
    Xiong Bin
    Guo Hui
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [49] Thermodynamic analysis of ammonia-water power/chilling cogeneration cycle with low-grade waste heat
    Hua, Junye
    Chen, Yaping
    Wang, Yaodong
    Roskilly, A. P.
    APPLIED THERMAL ENGINEERING, 2014, 64 (1-2) : 483 - 490
  • [50] Thermodynamic and exergoeconomic analysis of a combined cooling, desalination and power system for low-grade waste heat utilization
    Zhou, Shihe
    Zhang, Kechong
    Li, Min
    Yang, Wenkuan
    Shen, Shengqiang
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 45