Thermodynamic analysis and comparison of a novel dual-ejector based organic flash combined power and refrigeration cycle driven by the low-grade heat source

被引:38
|
作者
Tang, Zuohang [1 ]
Wu, Chuang [1 ]
Liu, Chao [1 ]
Xu, Xiaoxiao [1 ]
Liu, Jiangyan [1 ]
机构
[1] Chongqing Univ, Sch Energy & Power Engn, Minist Educ, Key Lab Lowgrade Energy Utilizat Technol & Syst, Chongqing 400044, Peoples R China
关键词
Combined power and refrigeration cycle; Organic flash cycle; Ejector; Low-grade heat source; THERMOECONOMIC ANALYSIS; CARBON-DIOXIDE; RANKINE-CYCLE; KALINA CYCLE; RECOVERY; DESIGN; OFC; OPTIMIZATION; PROPOSAL; ORC;
D O I
10.1016/j.enconman.2021.114205
中图分类号
O414.1 [热力学];
学科分类号
摘要
This proposes a novel dual-ejector based organic flash combined power and refrigeration cycle, which replaces the two throttle valves with two ejectors for the basic flash cycle, to provide power and cooling simultaneously for users. Detailed mathematical models of the proposed system are built and validated. The preliminary analysis results show that the exergy efficiency reaches 45.59% under geothermal water at 150celcius. Then a parametric analysis is conducted to investigate the effects of five key parameters on system performance. The results show that both an optimal flash pressure and an extraction pressure exist to maximize the exergy efficiency. Finally, the proposed cycle, the separated power and refrigeration cycle consisting of a basic organic flash cycle and an ejector refrigeration cycle, and the basic organic flash cycle are optimized and compared by examining seven different organic fluids such as R245fa, R141b, R123, R245ca, R601, R365mfc, and R600. The results show that the R245fa brings the highest exergy efficiency to both the proposed cycle and organic flash cycle among seven involved organic fluids. Compared with the basic organic flash cycle, the proposed cycle with R245fa has a 4.91% percentage point higher exergy efficiency, 10.44% higher net power output, and an extra 172.6 kW of refrigeration output. Meanwhile, the optimal exergy efficiency and net power output of the proposed cycle are 5.82-6.80% percentage point higher and 15.06-23.87% higher than those of the separated power and refrigeration cycle. An exergy analysis suggests that the throttling losses are indeed significantly reduced by replacing the throttle valves with the ejectors for the organic flash cycle.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Thermodynamic analysis of hybrid heat source driven organic Rankine cycle integrated flash tank vapor-compression refrigeration system
    Ashwni
    Sherwani, Ahmad Faizan
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 129 : 267 - 277
  • [32] Performance Analysis of a Combined Absorption Refrigeration-Liquid Desiccant Dehumidification THIC System Driven by Low-Grade Heat Source
    XU Cong
    SUI Jun
    DAI Yuze
    LIU Feng
    LIU Hao
    JournalofThermalScience, 2020, 29 (05) : 1193 - 1205
  • [33] Performance Analysis of a Combined Absorption Refrigeration-Liquid Desiccant Dehumidification THIC System Driven by Low-Grade Heat Source
    Xu, Cong
    Sui, Jun
    Dai, Yuze
    Liu, Feng
    Liu, Hao
    JOURNAL OF THERMAL SCIENCE, 2020, 29 (05) : 1193 - 1205
  • [34] Performance Analysis of a Combined Absorption Refrigeration-Liquid Desiccant Dehumidification THIC System Driven by Low-Grade Heat Source
    Cong Xu
    Jun Sui
    Yuze Dai
    Feng Liu
    Hao Liu
    Journal of Thermal Science, 2020, 29 : 1193 - 1205
  • [35] Thermodynamic performance analysis of a combined power cycle using low grade heat source and LNG cold energy
    Kim, Kyoung Hoon
    Kim, Kyung Chun
    APPLIED THERMAL ENGINEERING, 2014, 70 (01) : 50 - 60
  • [36] Off-design performance analysis of a combined cooling and power system driven by low-grade heat source
    Du, Yang
    Han, Pengfei
    Qiang, Xiongchao
    Hao, Muting
    Long, Ying
    Zhao, Pan
    Dai, Yiping
    ENERGY CONVERSION AND MANAGEMENT, 2018, 159 : 327 - 341
  • [37] Thermodynamic and economic analysis and multi-objective optimization of a novel transcritical CO2 Rankine cycle with an ejector driven by low grade heat source
    Xia, Jiaxi
    Wang, Jiangfeng
    Zhou, Kehan
    Zhao, Pan
    Dai, Yiping
    ENERGY, 2018, 161 : 337 - 351
  • [38] Comprehensive analysis of a novel power and cooling cogeneration system based on organic Rankine cycle and ejector refrigeration cycle
    Yu, Wei
    Wang, Huitao
    Ge, Zhong
    ENERGY CONVERSION AND MANAGEMENT, 2021, 232
  • [39] Analysis of power cycle based on cold energy of liquefied natural gas and low-grade heat source
    Qiang, W
    Li, YZ
    Jiang, W
    APPLIED THERMAL ENGINEERING, 2004, 24 (04) : 539 - 548
  • [40] Thermodynamic and thermoeconomic analysis and optimization of a novel combined cooling and power (CCP) cycle by integrating of ejector refrigeration and Kalina cycles
    Ghaebi, Hadi
    Parikhani, Towhid
    Rostamzadeh, Hadi
    Farhang, Behzad
    ENERGY, 2017, 139 : 262 - 276