Ammonia recovery from anaerobic digester centrate using onsite pilot scale bipolar membrane electrodialysis coupled to membrane stripping

被引:36
|
作者
Ferrari, Federico [1 ,2 ]
Pijuan, Maite [1 ,2 ]
Molenaar, Sam [3 ]
Duinslaeger, Nick [1 ,2 ]
Sleutels, Tom [4 ]
Kuntke, Philipp [4 ,5 ]
Radjenovic, Jelena [1 ,6 ]
机构
[1] Catalan Inst Water Res ICRA, Emili Grahit 101, Girona 17003, Spain
[2] Univ Girona, Girona 17003, Spain
[3] W&F Technol, Noordhaven 88a, NL-4761 DC Zevenbergen, Netherlands
[4] Wetsus, European Ctr Excellence Sustainable Water Technol, POB 1113,Oostergoweg 9,8911, NL-8900 CC Leeuwarden, Netherlands
[5] Wageningen Univ, Environm Technol, POB 17,Bornse Weilanden 9, NL-6700 AA Wageningen, Netherlands
[6] Catalan Inst Res & Adv Studies ICREA, Passeig Lluis Co 23, Barcelona 08010, Spain
关键词
Bipolar membrane electrodialysis; Pilot scale; Ammonia recovery; Membrane stripping; PFAS; WASTE-WATER TREATMENT; NITROUS-OXIDE EMISSIONS; NUTRIENT RECOVERY; PERFLUOROALKYL SUBSTANCES; ENERGY; URINE; POLLUTANTS; BIOSOLIDS; REMOVAL; GAS;
D O I
10.1016/j.watres.2022.118504
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ammonia recovery from centrate of an anaerobic digester was investigated using an onsite bipolar-electrodialysis (BP-ED) pilot scale plant coupled to two liquid/liquid membrane contactor (LLMC) modules. To investigate the process performance and robustness, the pilot plant was operated at varying current densities, load ratio (current to nitrogen loading), and in continuous and intermittent current (Donnan) mode. A higher load ratio led to higher total ammonium nitrogen (TAN, sum of ammonia and ammonium) removal efficiency, whereas the increase in the applied current did not have a significant impact the TAN removal efficiency. Continuous current application resulted in the higher TAN removal compared with the Donnan dialysis mode. The lowest specific energy consumption of 6.3 kWh kgN(-1) was recorded in the Donnan mode, with the load ratio of 1.4, at 200 L h(-1) flowrate and current density of 75 A m(-2). Lower energy demand observed in the Donnan mode was likely due to the lower scaling and fouling of the ion exchange membranes. Nevertheless, scaling and fouling limited the operation of the BP-ED stack in all operational modes, which had to be interrupted by the daily cleaning procedures. The LLMC module enabled a highly selective recovery of ammonia as ammonium sulfate ((NH4)(2)SO4), with the concentration of ammonia ranging from 19 to 33 gN L-1. However, the analysis of per-and polyfluoroalkyl substances (PFASs) in the obtained (NH4)(2)SO4 product revealed the presence of 212-253 ng L-1 of 6:2 fluorotelomer sulfonate (FTS), a common substitute of legacy PFAS. Given the very low concentrations of 6:2 FTS (i.e., < 2 ng L-1) encountered in the concentrated stream, 6:2 FTS was likely released from the Teflon-based components in the sulfuric acid dosage line. Thus, careful selection of the pilot plant tubing, pumps and other components is required to avoid any risks associated with the PFAS presence and ensure safe use of the final product as fertilizer.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Simultaneous Separation and Recovery of Phosphorus from Aqueous Solution by Bipolar Membrane Electrodialysis
    Iizuka, Atsushi
    Ho, Hsing-Jung
    Sugimoto, Tatsuya
    Adachi, Ken
    Shibata, Etsuro
    ISIJ INTERNATIONAL, 2023, 63 (07) : 1172 - 1177
  • [42] Recovery of acetic acid from dilute wastewater by means of bipolar membrane electrodialysis
    Yu, LX
    Guo, QF
    Hao, JH
    Jiang, WJ
    DESALINATION, 2000, 129 (03) : 283 - 288
  • [43] Effective nutrient recovery from digester centrate assisted by in situ production of acid/base in a novel electrochemical membrane system
    Liu, Fubin
    Moustafa, Hanan
    Hassouna, Mohammed Salah El -Din
    He, Zhen
    CHEMOSPHERE, 2022, 307
  • [44] Recovery of Acid and Base from Sodium Sulfate Containing Lithium Carbonate Using Bipolar Membrane Electrodialysis
    Gao, Wenjie
    Fang, Qinxiang
    Yan, Haiyang
    Wei, Xinlai
    Wu, Ke
    MEMBRANES, 2021, 11 (02) : 1 - 15
  • [45] Effect of process conditions on recovery of lithium and boron from water using bipolar membrane electrodialysis (BMED)
    Bunani, Samuel
    Arda, Muserref
    Kabay, Nalan
    Yoshizuka, Kazuharu
    Nishihama, Syouhei
    DESALINATION, 2017, 416 : 10 - 15
  • [46] Recovery of alpha-ketoglutaric acid from model fermentation broth using electrodialysis with bipolar membrane
    Szczygielda, Mateusz
    Prochaska, Krystyna
    SEPARATION SCIENCE AND TECHNOLOGY, 2020, 55 (01) : 165 - 175
  • [47] Large scale experiment on the preparation of vitamin C from sodium ascorbate using bipolar membrane electrodialysis
    Yu, LX
    Lin, AG
    Zhang, LP
    Jiang, WJ
    CHEMICAL ENGINEERING COMMUNICATIONS, 2002, 189 (02) : 237 - 246
  • [48] Carbon dioxide capture coupled with magnesium utilization from seawater by bipolar membrane electrodialysis
    Chen, Tianyi
    Bi, Jingtao
    Zhao, Yingying
    Du, Zhongte
    Guo, Xiaofu
    Yuan, Junsheng
    Ji, Zhiyong
    Liu, Jie
    Wang, Shizhao
    Li, Fei
    Wang, Jing
    SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 820
  • [49] Construction of bipolar membrane electrodialysis reactor for removal and recovery of nitrogen and phosphorus from wastewater
    Cao, Yinghan
    Li, Xinling
    Zhang, Li
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2023, 18 (03):
  • [50] Nutrient recovery as struvite from aquaculture wastewater by bipolar membrane electrodialysis with magnesite tailings
    Jin, Yanchao
    Li, Zheng
    Wang, Guodong
    Zhou, Zijing
    Ho, Shih-Hsin
    Li, Li-Ping
    Chen, Xiao
    Ding, Rui
    Liu, Jianxi
    Chen, Riyao
    SEPARATION AND PURIFICATION TECHNOLOGY, 2024, 330