Ammonia recovery from anaerobic digester centrate using onsite pilot scale bipolar membrane electrodialysis coupled to membrane stripping

被引:36
|
作者
Ferrari, Federico [1 ,2 ]
Pijuan, Maite [1 ,2 ]
Molenaar, Sam [3 ]
Duinslaeger, Nick [1 ,2 ]
Sleutels, Tom [4 ]
Kuntke, Philipp [4 ,5 ]
Radjenovic, Jelena [1 ,6 ]
机构
[1] Catalan Inst Water Res ICRA, Emili Grahit 101, Girona 17003, Spain
[2] Univ Girona, Girona 17003, Spain
[3] W&F Technol, Noordhaven 88a, NL-4761 DC Zevenbergen, Netherlands
[4] Wetsus, European Ctr Excellence Sustainable Water Technol, POB 1113,Oostergoweg 9,8911, NL-8900 CC Leeuwarden, Netherlands
[5] Wageningen Univ, Environm Technol, POB 17,Bornse Weilanden 9, NL-6700 AA Wageningen, Netherlands
[6] Catalan Inst Res & Adv Studies ICREA, Passeig Lluis Co 23, Barcelona 08010, Spain
关键词
Bipolar membrane electrodialysis; Pilot scale; Ammonia recovery; Membrane stripping; PFAS; WASTE-WATER TREATMENT; NITROUS-OXIDE EMISSIONS; NUTRIENT RECOVERY; PERFLUOROALKYL SUBSTANCES; ENERGY; URINE; POLLUTANTS; BIOSOLIDS; REMOVAL; GAS;
D O I
10.1016/j.watres.2022.118504
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ammonia recovery from centrate of an anaerobic digester was investigated using an onsite bipolar-electrodialysis (BP-ED) pilot scale plant coupled to two liquid/liquid membrane contactor (LLMC) modules. To investigate the process performance and robustness, the pilot plant was operated at varying current densities, load ratio (current to nitrogen loading), and in continuous and intermittent current (Donnan) mode. A higher load ratio led to higher total ammonium nitrogen (TAN, sum of ammonia and ammonium) removal efficiency, whereas the increase in the applied current did not have a significant impact the TAN removal efficiency. Continuous current application resulted in the higher TAN removal compared with the Donnan dialysis mode. The lowest specific energy consumption of 6.3 kWh kgN(-1) was recorded in the Donnan mode, with the load ratio of 1.4, at 200 L h(-1) flowrate and current density of 75 A m(-2). Lower energy demand observed in the Donnan mode was likely due to the lower scaling and fouling of the ion exchange membranes. Nevertheless, scaling and fouling limited the operation of the BP-ED stack in all operational modes, which had to be interrupted by the daily cleaning procedures. The LLMC module enabled a highly selective recovery of ammonia as ammonium sulfate ((NH4)(2)SO4), with the concentration of ammonia ranging from 19 to 33 gN L-1. However, the analysis of per-and polyfluoroalkyl substances (PFASs) in the obtained (NH4)(2)SO4 product revealed the presence of 212-253 ng L-1 of 6:2 fluorotelomer sulfonate (FTS), a common substitute of legacy PFAS. Given the very low concentrations of 6:2 FTS (i.e., < 2 ng L-1) encountered in the concentrated stream, 6:2 FTS was likely released from the Teflon-based components in the sulfuric acid dosage line. Thus, careful selection of the pilot plant tubing, pumps and other components is required to avoid any risks associated with the PFAS presence and ensure safe use of the final product as fertilizer.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Developing a vacuum thermal stripping - acid absorption process for ammonia recovery from anaerobic digester effluent
    Ukwuani, Anayo T.
    Tao, Wendong
    WATER RESEARCH, 2016, 106 : 108 - 115
  • [32] Identification of Fouling Occurring during Coupled Electrodialysis and Bipolar Membrane Electrodialysis Treatment for Tofu Whey Protein Recovery
    Deschenes Gagnon, Rosie
    Langevin, Marie-eve
    Lutin, Florence
    Bazinet, Laurent
    MEMBRANES, 2024, 14 (04)
  • [33] Recovery of ammonia nitrogen from landfill leachate using a biopolar membrane equipped electrodialysis system
    Zhang, Cunkuan
    Ding, Wenchuan
    Zeng, Xiaolan
    Xu, Xiaotang
    WATER SCIENCE AND TECHNOLOGY, 2020, 82 (09) : 1758 - 1770
  • [34] Phosphorus recovery from anaerobic digester supernatants using a pilot-scale struvite crystallization process
    Mavinic, D. S.
    Koch, F. A.
    Huang, H.
    Lo, K. V.
    JOURNAL OF ENVIRONMENTAL ENGINEERING AND SCIENCE, 2007, 6 (05) : 561 - 571
  • [35] Boron recovery from wastewater using a self-powered bipolar membrane electrodialysis system
    Xie, Lijuan
    Wu, Xiaoyun
    Pan, Yan
    Lv, Mingzhi
    Liu, Yaoxing
    Lian, Rui
    Jiang, Jie
    Chen, Riyao
    Ding, Rui
    Liu, Jianxi
    SEPARATION AND PURIFICATION TECHNOLOGY, 2025, 364
  • [36] Capacitive membrane stripping for ammonia recovery (CapAmm) from dilute wastewaters
    Zhang Changyong
    Ma, Jinxing
    Waite, David
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 256
  • [37] Capacitive Membrane Stripping for Ammonia Recovery (CapAmm) from Dilute Wastewaters
    Zhang, Changyong
    Ma, Jinxing
    He, Di
    Waite, T. David
    ENVIRONMENTAL SCIENCE & TECHNOLOGY LETTERS, 2018, 5 (01): : 43 - 49
  • [38] Recovery of acetic acid from simulated acetaldehyde wastewaters: Bipolar membrane electrodialysis processes and membrane selection
    Zhang, Xu
    Li, Chuanrun
    Wang, Yaoming
    Luo, Jingyi
    Xu, Tongwen
    JOURNAL OF MEMBRANE SCIENCE, 2011, 379 (1-2) : 184 - 190
  • [39] Lactic acid recovery from fermentation by bipolar membrane electrodialysis and ionic migration
    Lin, Han
    Wang, Qunhui
    Wang, Lijuan
    Li, Yan
    Chen, Huanxi
    Huagong Xuebao/CIESC Journal, 2014, 65 (12): : 4823 - 4830
  • [40] Removal and recovery of boric acid from waste water with bipolar membrane electrodialysis
    Yamasaki, Akihiro
    Nakamura, Yurina
    Itabashi, Misa
    Shoji, Tadashi
    Noguchi, Miyuki
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 254