Ammonia recovery from anaerobic digester centrate using onsite pilot scale bipolar membrane electrodialysis coupled to membrane stripping

被引:36
|
作者
Ferrari, Federico [1 ,2 ]
Pijuan, Maite [1 ,2 ]
Molenaar, Sam [3 ]
Duinslaeger, Nick [1 ,2 ]
Sleutels, Tom [4 ]
Kuntke, Philipp [4 ,5 ]
Radjenovic, Jelena [1 ,6 ]
机构
[1] Catalan Inst Water Res ICRA, Emili Grahit 101, Girona 17003, Spain
[2] Univ Girona, Girona 17003, Spain
[3] W&F Technol, Noordhaven 88a, NL-4761 DC Zevenbergen, Netherlands
[4] Wetsus, European Ctr Excellence Sustainable Water Technol, POB 1113,Oostergoweg 9,8911, NL-8900 CC Leeuwarden, Netherlands
[5] Wageningen Univ, Environm Technol, POB 17,Bornse Weilanden 9, NL-6700 AA Wageningen, Netherlands
[6] Catalan Inst Res & Adv Studies ICREA, Passeig Lluis Co 23, Barcelona 08010, Spain
关键词
Bipolar membrane electrodialysis; Pilot scale; Ammonia recovery; Membrane stripping; PFAS; WASTE-WATER TREATMENT; NITROUS-OXIDE EMISSIONS; NUTRIENT RECOVERY; PERFLUOROALKYL SUBSTANCES; ENERGY; URINE; POLLUTANTS; BIOSOLIDS; REMOVAL; GAS;
D O I
10.1016/j.watres.2022.118504
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ammonia recovery from centrate of an anaerobic digester was investigated using an onsite bipolar-electrodialysis (BP-ED) pilot scale plant coupled to two liquid/liquid membrane contactor (LLMC) modules. To investigate the process performance and robustness, the pilot plant was operated at varying current densities, load ratio (current to nitrogen loading), and in continuous and intermittent current (Donnan) mode. A higher load ratio led to higher total ammonium nitrogen (TAN, sum of ammonia and ammonium) removal efficiency, whereas the increase in the applied current did not have a significant impact the TAN removal efficiency. Continuous current application resulted in the higher TAN removal compared with the Donnan dialysis mode. The lowest specific energy consumption of 6.3 kWh kgN(-1) was recorded in the Donnan mode, with the load ratio of 1.4, at 200 L h(-1) flowrate and current density of 75 A m(-2). Lower energy demand observed in the Donnan mode was likely due to the lower scaling and fouling of the ion exchange membranes. Nevertheless, scaling and fouling limited the operation of the BP-ED stack in all operational modes, which had to be interrupted by the daily cleaning procedures. The LLMC module enabled a highly selective recovery of ammonia as ammonium sulfate ((NH4)(2)SO4), with the concentration of ammonia ranging from 19 to 33 gN L-1. However, the analysis of per-and polyfluoroalkyl substances (PFASs) in the obtained (NH4)(2)SO4 product revealed the presence of 212-253 ng L-1 of 6:2 fluorotelomer sulfonate (FTS), a common substitute of legacy PFAS. Given the very low concentrations of 6:2 FTS (i.e., < 2 ng L-1) encountered in the concentrated stream, 6:2 FTS was likely released from the Teflon-based components in the sulfuric acid dosage line. Thus, careful selection of the pilot plant tubing, pumps and other components is required to avoid any risks associated with the PFAS presence and ensure safe use of the final product as fertilizer.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Membrane Contactors for Ammonia Recovery from Anaerobic Digester Centrate: Pretreatment and Process Optimization
    Schwiebert, Alexander M.
    Bush, John A.
    Bellona, Christopher
    Vanneste, Johan
    Cath, Tzahi Y.
    ACS ES&T WATER, 2024, 4 (08): : 3284 - 3296
  • [2] Recovery of ammonia from simulated membrane contactor effluent using bipolar membrane electrodialysis
    Saabas, David
    Lee, Jongho
    JOURNAL OF MEMBRANE SCIENCE, 2022, 644
  • [3] Nutrient recovery and fractionation of anaerobic digester effluents employing pilot scale membrane technology
    Zacharof, Myrto-Panagiota
    Mandale, Stephen J.
    Oatley-Radcliffe, Darren
    Lovitt, Robert W.
    JOURNAL OF WATER PROCESS ENGINEERING, 2019, 31
  • [4] Bipolar membrane electrodialysis for nutrient recovery from anaerobic digestion dewatering sidestream
    Chen, Weikun
    Grimberg, Stefan
    Rogers, Shane
    Kim, Taeyoung
    CHEMICAL ENGINEERING JOURNAL, 2024, 488
  • [5] Electrochemical Ammonia Recovery from Anaerobic Centrate Using a Nickel-Functionalized Activated Carbon Membrane Electrode
    Kim, Kyoung-Yeol
    Moreno-Jimenez, Daniel A.
    Efstathiadis, Harry
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2021, 55 (11) : 7674 - 7680
  • [6] Recovery of ammonia nitrogen from simulated reject water by bipolar membrane electrodialysis
    Zhu, Ming
    Chi, Yongzhi
    Zhou, Weifeng
    Chen, Fuqiang
    Huang, Hanwen
    He, Feiyu
    Tian, Sufeng
    Wang, Xueke
    Li, Yu-You
    Fu, Cuilian
    ENVIRONMENTAL TECHNOLOGY, 2025, 46 (08) : 1147 - 1159
  • [7] Ammonia separation fromwastewater using bipolar membrane electrodialysis
    Mohammadi, Mariam
    Guo, Hui
    Yuan, Pengyi
    Pavlovic, Vladimir
    Barber, John
    Kim, Younggy
    ELECTROCHEMICAL SCIENCE ADVANCES, 2021, 1 (04):
  • [8] Ammonia-selective recovery from anaerobic digestate using electrochemical ammonia stripping combined with electrodialysis
    Aung, Shine Lin
    Choi, Jihyeok
    Cha, Hoyoung
    Woo, Gaeun
    Song, Kyung Guen
    CHEMICAL ENGINEERING JOURNAL, 2024, 479
  • [9] Enhancing ammonia recovery through pH polarization in bipolar membrane electrodialysis
    Panagoda, Sandali
    Yuan, Pengyi
    Pavlovic, Vladimir
    Barber, John
    Kim, Younggy
    ENVIRONMENTAL SCIENCE-ADVANCES, 2024, 3 (09): : 1309 - 1316
  • [10] Microbial electrochemical ammonia recovery from anaerobic digester centrate and subsequent application to fertilize Arabidopsis thaliana
    Liu, Fubin
    Worland, Alyssa
    Tang, Yinjie
    Moustafa, Hanan
    Hassouna, Mohammed Salah El-Din
    He, Zhen
    WATER RESEARCH, 2022, 220