A novel probe for measuring tissue bioelectrical impedance to enhance pedicle screw placement in spinal surgery

被引:0
|
作者
Li, Zheng [1 ,2 ]
Chen, Chong [1 ,2 ]
Lin, Youxi [1 ,2 ]
Li, Xingye [3 ]
Tan, Haining [1 ,2 ]
Chan, Matthew T., V [4 ]
Wu, William K. K. [4 ,5 ]
Zhan, Songtao [6 ]
Cao, Qun [6 ]
Shen, Jianxiong [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Dept Orthopaed Surg, Peking Union Med Coll Hosp, Beijing 100730, Peoples R China
[2] Peking Union Med Coll, Beijing 100730, Peoples R China
[3] Tsinghua Univ, Beijing Jishuitan Hosp, Jishuitan Orthopaed Coll, Clin Coll 4,Dept Orthoped Surg,Peking Univ, Beijing, Peoples R China
[4] Chinese Univ Hong Kong, Dept Anaesthesia & Intens Care, Hong Kong, Hong Kong, Peoples R China
[5] Chinese Univ Hong Kong, State Key Lab Digest Dis, LKS Inst Hlth Sci, Hong Kong, Hong Kong, Peoples R China
[6] Beijing SMTP Technol Co LTD, Beijing, Peoples R China
来源
基金
北京市自然科学基金;
关键词
Pedicle screws; severe spinal deformities; bioelectrical impedance; probe; ADOLESCENT IDIOPATHIC SCOLIOSIS; POSTERIOR INSTRUMENTATION; BODY-COMPOSITION; FIXATION; FUSION; MASS; COMPLICATIONS; ACCURACY; CHILDREN; EFFICACY;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Posterior spinal reconstruction with rods and pedicle screws has been widely used to corrects coliosis and other forms of degenerative spinal deformities. However, insertion of pedicle screwsis often clinically challenging, particularlyin patients with severe deformity. Bioelectrical impedance analysis is a technique that exploits the electrical properties of biological organs and tissues to indicate their compositions. Bioelectrical impedance measurement is non-invasive, simple, with adequate repeatability, and at a relatively low cost. In our study, we designed a bioelectrical impedance pedicle probe and use it to determine the bioelectrical impedance values in vitro and in vivo of different tissues relevant to pedicle screw insertion. We measured the bioelectrical impedance of different tissues relevant to pedicle screw placement in vitro and in vivo and explored the use of a prototype bioelectrical impedance pedicle probein guiding pedicle screw placement during spine surgery in animals. These data suggested that this novel bioelectrical impedance pedicle probe may be a new technique that has potential to offer accurate and safe placement of pedicle screws in spine surgery.
引用
收藏
页码:2205 / 2212
页数:8
相关论文
共 50 条
  • [31] Novel Applications of Spinal Navigation in Deformity and Oncology Surgery-Beyond Screw Placement
    Massaad, Elie
    Shankar, Ganesh M.
    Shin, John H.
    OPERATIVE NEUROSURGERY, 2021, 21 : S23 - S38
  • [32] Computer-Assisted Screw Size and Insertion Trajectory Planning for Pedicle Screw Placement Surgery
    Knez, Dejan
    Likar, Bostjan
    Pernus, Franjo
    Vrtovec, Tomaz
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (06) : 1420 - 1430
  • [33] Ultrasound guided placement of pedicle screws in spinal fusion surgery
    Mujagic, Muris
    Ginsberg, Howard J.
    Cobbold, Richard S. C.
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 212 - 215
  • [34] Ultrasound propagation characteristics within the bone tissue of miniature ultrasound probes: implications for the spinal navigation of pedicle screw placement
    Li, Peiyang
    Li, Suoyuan
    Li, Zhiqiang
    Lu, Wenjia
    Shao, Weiwei
    Li, Zhangjian
    Xu, Yiwen
    Zhang, Hong
    Ju, Bin
    Shen, Jun
    Cui, Yaoyao
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (07) : 4878 - 4892
  • [35] Pedicle screw placement accuracy in thoracic and lumbar spinal surgery with a patient-matched targeting guide: a cadaveric study
    Claudio Lamartina
    Riccardo Cecchinato
    Zsolt Fekete
    Alberto Lipari
    Meinrad Fiechter
    P. Berjano
    European Spine Journal, 2015, 24 : 937 - 941
  • [36] Precision and accuracy of consumer-grade motion tracking system for pedicle screw placement in pediatric spinal fusion surgery
    Chan, Andrew
    Aguillon, Janelle
    Hill, Doug
    Lou, Edmond
    MEDICAL ENGINEERING & PHYSICS, 2017, 46 : 33 - 43
  • [37] Novel synthetic vertebrae provide realistic haptics for pedicle screw placement
    Hollensteiner, Marianne
    Augat, Peter
    Fuerst, David
    Esterer, Benjamin
    Gabauer, Stefan
    Pueschel, Klaus
    Schroedl, Falk
    Schrempf, Andreas
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 46 - 49
  • [38] Pedicle screw placement accuracy in thoracic and lumbar spinal surgery with a patient-matched targeting guide: a cadaveric study
    Lamartina, Claudio
    Cecchinato, Riccardo
    Fekete, Zsolt
    Lipari, Alberto
    Fiechter, Meinrad
    Berjano, P.
    EUROPEAN SPINE JOURNAL, 2015, 24 : S937 - S941
  • [39] C2 Pedicle Screw Placement: A Novel Teaching Aid
    Ajayi, Olaide
    Moisi, Marc
    Chapman, Jens
    Oskouian, Rod J.
    Tubbs, R. Shane
    CUREUS, 2016, 8 (06):
  • [40] Application of a Novel Attachable Magnetic Nerve Stimulating Probe in Intraoperative Lumbar Pedicle Screw Placement: A Porcine Model Study
    Goh, Tae Sik
    Shin, Sung-Chan
    Kwon, Hyun-Keun
    Sung, Eui-Suk
    Jun, Se Bin
    Lee, Byung-Joo
    Lee, Jung Sub
    APPLIED SCIENCES-BASEL, 2021, 11 (17):