A novel probe for measuring tissue bioelectrical impedance to enhance pedicle screw placement in spinal surgery

被引:0
|
作者
Li, Zheng [1 ,2 ]
Chen, Chong [1 ,2 ]
Lin, Youxi [1 ,2 ]
Li, Xingye [3 ]
Tan, Haining [1 ,2 ]
Chan, Matthew T., V [4 ]
Wu, William K. K. [4 ,5 ]
Zhan, Songtao [6 ]
Cao, Qun [6 ]
Shen, Jianxiong [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Dept Orthopaed Surg, Peking Union Med Coll Hosp, Beijing 100730, Peoples R China
[2] Peking Union Med Coll, Beijing 100730, Peoples R China
[3] Tsinghua Univ, Beijing Jishuitan Hosp, Jishuitan Orthopaed Coll, Clin Coll 4,Dept Orthoped Surg,Peking Univ, Beijing, Peoples R China
[4] Chinese Univ Hong Kong, Dept Anaesthesia & Intens Care, Hong Kong, Hong Kong, Peoples R China
[5] Chinese Univ Hong Kong, State Key Lab Digest Dis, LKS Inst Hlth Sci, Hong Kong, Hong Kong, Peoples R China
[6] Beijing SMTP Technol Co LTD, Beijing, Peoples R China
来源
基金
北京市自然科学基金;
关键词
Pedicle screws; severe spinal deformities; bioelectrical impedance; probe; ADOLESCENT IDIOPATHIC SCOLIOSIS; POSTERIOR INSTRUMENTATION; BODY-COMPOSITION; FIXATION; FUSION; MASS; COMPLICATIONS; ACCURACY; CHILDREN; EFFICACY;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Posterior spinal reconstruction with rods and pedicle screws has been widely used to corrects coliosis and other forms of degenerative spinal deformities. However, insertion of pedicle screwsis often clinically challenging, particularlyin patients with severe deformity. Bioelectrical impedance analysis is a technique that exploits the electrical properties of biological organs and tissues to indicate their compositions. Bioelectrical impedance measurement is non-invasive, simple, with adequate repeatability, and at a relatively low cost. In our study, we designed a bioelectrical impedance pedicle probe and use it to determine the bioelectrical impedance values in vitro and in vivo of different tissues relevant to pedicle screw insertion. We measured the bioelectrical impedance of different tissues relevant to pedicle screw placement in vitro and in vivo and explored the use of a prototype bioelectrical impedance pedicle probein guiding pedicle screw placement during spine surgery in animals. These data suggested that this novel bioelectrical impedance pedicle probe may be a new technique that has potential to offer accurate and safe placement of pedicle screws in spine surgery.
引用
收藏
页码:2205 / 2212
页数:8
相关论文
共 50 条
  • [21] Novel Pedicle Navigator Based on Micro Inertial Navigation System (MINS) and Bioelectric Impedance Analysis (BIA) to Facilitate Pedicle Screw Placement in Spine Surgery: Study in a Porcine Model
    Lin, Wentao
    Xie, Faqin
    Zhao, Shuofeng
    Lin, Songhui
    He, Chaoqin
    Wang, Zhiyun
    SPINE, 2022, 47 (16) : 1172 - 1178
  • [22] A novel guide device improves the accuracy of pedicle screw placement
    Yang, Lei
    Li, Haijun
    Tang, Jian
    Ge, Dawei
    Cao, Xiaojian
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (06): : 8634 - 8640
  • [23] A novel entry point for pedicle screw placement in the thoracic spine
    Sun, Zhifeng
    Yang, Kaixiang
    Chen, Hongtao
    Sui, Tao
    Yang, Lei
    Ge, Dawei
    Tang, Jian
    Cao, Xiaojian
    JOURNAL OF BIOMEDICAL RESEARCH, 2018, 32 (02): : 123 - 129
  • [24] A novel entry point for pedicle screw placement in the thoracic spine
    Zhifeng Sun
    Kaixiang Yang
    Hongtao Chen
    Tao Sui
    Lei Yang
    Dawei Ge
    Jian Tang
    Xiaojian Cao
    The Journal of Biomedical Research, 2018, 32 (02) : 123 - 129
  • [25] Accuracy of Pedicle Screw Placement Methods in Pediatrics and Adolescents Spinal Surgery: A Systematic Review and Meta-Analysis
    De Vega, Brigita
    Navarro, Aida Ribera
    Gibson, Alexander
    Kalaskar, Deepak M.
    GLOBAL SPINE JOURNAL, 2022, 12 (04) : 677 - 688
  • [26] Cortical pedicle screw placement in lumbar spinal surgery with a patient-matched targeting guide: A cadaveric study
    Kaito, Takashi
    Matsukawa, Keitaro
    Abe, Yuichiro
    Fiechter, Meinrad
    Zhu, Xia
    Fantigrossi, Alfonso
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2018, 23 (06) : 865 - 869
  • [27] Improved Accuracy and Safety of Pedicle Screw Placement by Using a Probe with an Electrical Conductivity-Measuring Device during Severe Syndromic and Neuromuscular Scoliosis Spine Surgery
    Yurube, Takashi
    Kanda, Yutaro
    Ito, Masaaki
    Takeoka, Yoshiki
    Suzuki, Teppei
    Uno, Koki
    Kuroda, Ryosuke
    Kakutani, Kenichiro
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (02)
  • [28] Accuracy of pedicle screw placement in scoliosis surgery by means of computed tomography
    Halm, H
    Liljenqvist, U
    Link, T
    Jerosch, J
    Winkelmann, W
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1996, 134 (06): : 492 - 497
  • [29] ROBOTIC-ASSISTED PEDICLE SCREW PLACEMENT DURING SPINE SURGERY
    Lieberman, Isador H.
    Kisinde, Stanley
    Hesselbacher, Shea
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2020, 10 (02):
  • [30] SPINAL PEDICLE FIXATION - CONFIRMATION OF AN IMAGE-BASED TECHNIQUE FOR SCREW PLACEMENT
    STEINMANN, JC
    HERKOWITZ, HN
    ELKOMMOS, H
    WESOLOWSKI, DP
    SPINE, 1993, 18 (13) : 1856 - 1861